Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?

被引:38
作者
Liang, Ziyang [1 ]
Cui, Jianchao [2 ]
Zhang, Jiarui [1 ]
He, Jiahui [1 ]
Tang, Jingjing [2 ]
Ren, Hui [2 ]
Ye, Linqiang [3 ]
Liang, De [2 ]
Jiang, Xiaobing [2 ]
机构
[1] Guangzhou Univ Chinese Med, Clin Med Coll 1, Guangzhou 510405, Peoples R China
[2] Guangzhou Univ Chinese Med, Affiliated Hosp 1, Dept Spinal Surg, 16 Airport Rd, Guangzhou 510405, Guangdong, Peoples R China
[3] Dongguan Hosp Chinese Med, Dept Spinal Surg, Dongguan 523000, Peoples R China
关键词
FINITE-ELEMENT MODEL; POST-YIELD BEHAVIOR; SPINAL-FUSION; DISC; DEGENERATION; SENSITIVITY; FIXATION; GEOMETRY; SURGERY; BONE;
D O I
10.1186/s12891-020-3103-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundAdjacent segment disease (ASD) is a well-known complication after interbody fusion. Pedicle screw-rod revision possesses sufficient strength and rigidity. However, is a surgical segment with rigid fixation necessary for ASD reoperation? This study aimed to investigate the biomechanical effect of different instrumentation on lateral lumbar interbody fusion (LLIF) for ASD treatment.MethodsA validated L2 similar to 5 finite element (FE) model was modified for simulation. ASD was considered the level cranial to the upper-instrumented segment (L3/4). Bone graft fusion in LLIF with bilateral pedicle screw (BPS) fixation occurred at L4/5. The ASD segment for each group underwent a) LLIF + posterior extension of BPS, b) PLIF + posterior extension of BPS, c) LLIF + lateral screw, and d) stand-alone LLIF. The L3/4 range of motion (ROM), interbody cage stress and strain, screw-bone interface stress, cage-endplate interface stress, and L2/3 nucleus pulposus of intradiscal pressure (NP-IDP) analysis were calculated for comparisons among the four models.ResultsAll reconstructive models displayed decreased motion at L3/4. Under each loading condition, the difference was not significant between models a and b, which provided the maximum ROM reduction (73.8 to 97.7% and 68.3 to 98.4%, respectively). Model c also provided a significant ROM reduction (64.9 to 77.5%). Model d provided a minimal restriction of the ROM (18.3 to 90.1%), which exceeded that of model a by 13.1 times for flexion-extension, 10.3 times for lateral bending and 4.8 times for rotation. Model b generated greater cage stress than other models, particularly for flexion. The maximum displacement of the cage and the peak stress of the cage-endplate interface were found to be the highest in model d under all loading conditions. For the screw-bone interface, the stress was much greater with lateral instrumentation than with posterior instrumentation.ConclusionsStand-alone LLIF is likely to have limited stability, particularly for lateral bending and axial rotation. Posterior extension of BPS can provide reliable stability and excellent protective effects on instrumentation and endplates. However, LLIF with the use of an in situ screw may be an alternative for ASD reoperation.
引用
收藏
页数:14
相关论文
共 49 条
[21]  
Kyaw TA, 2014, EUR J ORTHOP SURG S1, V24, pS283, DOI DOI 10.1007/s00590-014-1416-1
[22]   Direct Lateral Approach to Lumbar Fusion Is a Biomechanically Equivalent Alternative to the Anterior Approach An In Vitro Study [J].
Laws, Cory J. ;
Coughlin, Dezba G. ;
Lotz, Jeffrey C. ;
Serhan, Hassan A. ;
Hu, Serena S. .
SPINE, 2012, 37 (10) :819-825
[23]   Biomechanical comparison of multilevel lateral interbody fusion with and without supplementary instrumentation: a three-dimensional finite element study [J].
Liu, Xilin ;
Ma, Jun ;
Park, Paul ;
Huang, Xiaodong ;
Xie, Ning ;
Ye, Xiaojian .
BMC MUSCULOSKELETAL DISORDERS, 2017, 18
[24]   Stand-alone lateral lumbar interbody fusion for the treatment of symptomatic adjacent segment degeneration following previous lumbar fusion [J].
Louie, Philip K. ;
Varthi, Arya G. ;
Narain, Ankur S. ;
Lei, Victor ;
Bohl, Daniel D. ;
Shifflett, Grant D. ;
Phillips, Frank M. .
SPINE JOURNAL, 2018, 18 (11) :2025-2032
[25]   Radiographic and clinical evaluation of cage subsidence after stand-alone lateral interbody fusion Clinical article [J].
Marchi, Luis ;
Abdala, Nitamar ;
Oliveira, Leonardo ;
Amaral, Rodrigo ;
Coutinho, Etevaldo ;
Pimenta, Luiz .
JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (01) :110-118
[26]   Biomechanical analysis of lateral interbody fusion strategies for adjacent segment degeneration in the lumbar spine [J].
Metzger, Melodie F. ;
Robinson, Samuel T. ;
Maldonado, Ruben C. ;
Rawlinson, Jeremy ;
Liu, John ;
Acosta, Frank L. .
SPINE JOURNAL, 2017, 17 (07) :1004-1011
[27]  
Murray G., 1997, HDB MAT SELECTION EN
[28]   Adjacent Segment Disease After Single Segment Posterior Lumbar Interbody Fusion for Degenerative Spondylolisthesis Minimum 10 Years Follow-up [J].
Okuda, Shinya ;
Nagamoto, Yukitaka ;
Matsumoto, Tomiya ;
Sugiura, Tsuyoshi ;
Takahashi, Yoshifumi ;
Iwasaki, Motoki .
SPINE, 2018, 43 (23) :E1384-E1388
[29]  
Ozgur Burak M, 2006, Spine J, V6, P435, DOI 10.1016/j.spinee.2005.08.012
[30]   Adjacent segment disease after lumbar or lumbosacral fusion: Review of the literature [J].
Park, P ;
Garton, HJ ;
Gala, VC ;
Hoff, JT ;
McGillicuddy, JE .
SPINE, 2004, 29 (17) :1938-1944