Full-scale calculation of the coupling losses in ITER size cable-in-conduit conductors

被引:24
|
作者
van Lanen, E. P. A. [1 ]
van Nugteren, J. [1 ]
Nijhuis, A. [1 ]
机构
[1] Univ Twente, Fac Sci & Technol, NL-7500 AE Enschede, Netherlands
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 2012年 / 25卷 / 02期
关键词
SUPERCONDUCTING CABLES; CONTACT RESISTANCE; FIELD; STABILITY;
D O I
10.1088/0953-2048/25/2/025012
中图分类号
O59 [应用物理学];
学科分类号
摘要
With the numerical cable model JackPot it is possible to calculate the interstrand coupling losses, generated by a time-changing background and self-field, between all strands in a cable-in-conduit conductor (CICC). For this, the model uses a system of equations in which the mutual inductances between all strand segments are calculated in advance. The model works well for analysing sub-size CICC sections. However, the exponential relationship between the model size and the computation time make it unpractical to simulate full size ITER CICC sections. For this reason, the multi-level fast multipole method (MLFMM) is implemented to control the computation load. For additional efficiency, it is written in a code that runs on graphics processing units, thereby utilizing an efficient low-cost parallel computation technique. A good accuracy is obtained with a considerably fast computation of the mutually induced voltages between all strands. This allows parametric studies on the coupling loss of long lengths of ITER size CICCs with the purpose of optimizing the cable design and to accurately compute the coupling loss for any applied magnetic field scenario.
引用
收藏
页数:8
相关论文
共 30 条
  • [21] Stability under transverse field pulse of the Nb3Sn ITER cable-in-conduit conductor
    Bruzzone, P
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 1062 - 1065
  • [22] Effects of contact resistance between strands with Cr/Non-Cr coating in Cable-In-Conduit Conductors
    Nakamura, K
    Yamanouchi, M
    Hashimoto, K
    Takao, T
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 1306 - 1309
  • [23] INTERSTRAND COUPLING EFFECT ON LOSSES AND CURRENT DISTRIBUTIONS IN SUPERCONDUCTING CABLE CONDUCTORS
    KAWABATA, S
    SUMIYOSHI, F
    KAWASHIMA, T
    MITO, T
    TAKAHATA, K
    TAKANO, H
    CRYOGENICS, 1994, 34 (04) : 293 - 301
  • [24] Results of Thermal Strain and Conductor Elongation Upon Heat Treatment for Nb3Sn Cable-in-Conduit Conductors
    Bruzzone, Pierluigi
    Wesche, Rainer
    Cau, Francesca
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 470 - 473
  • [25] Jack Pot: A novel model to study the influence of current non-uniformity and cabling patterns in cable-in-conduit conductors
    van Lanen, E. P. A.
    Nijhuis, A.
    CRYOGENICS, 2010, 50 (03) : 139 - 148
  • [26] Statistical Analysis of the Current-Sharing Temperature Evolution in Nb Sn Cable-in-Conduit-Conductors for ITER
    Uglietti, D.
    Wesche, R.
    Stepanov, B.
    Bruzzone, P.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
  • [27] Effect of cyclic loading and conductor layout on contact resistance of full-size ITER PFCI conductors
    Ilyin, YA
    Nijhuis, A
    Abbas, W
    Bruzzone, P
    Stepanov, B
    Muzzi, L
    Gislon, P
    Zani, L
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 1359 - 1362
  • [28] Successful performances of the EU-AltTF sample, a large size Nb3Sn cable-in-conduit conductor with rectangular geometry
    della Corte, A.
    Corato, V.
    Di Zenobio, A.
    Zignani, C. Fiamozzi
    Muzzi, L.
    Polli, G. M.
    Reccia, L.
    Turtu, S.
    Bruzzone, P.
    Salpietro, E.
    Vostner, A.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2010, 23 (04):
  • [29] Change of interstrand contact resistance and coupling loss in various prototype ITER NbTi conductors with transverse loading in the Twente Cryogenic Cable Press up to 40,000 cycles
    Nijhuis, A
    Ilyin, Y
    Abbas, W
    ten Haken, B
    ten Kate, HHJ
    CRYOGENICS, 2004, 44 (05) : 319 - 339
  • [30] Study of aggregation in surface sludge deposits from 14 full-scale French constructed wetlands using particle size distribution and dynamic vapor sorption analyses
    Kania, M.
    Gautier, M.
    Michel, P.
    Gourdon, R.
    WATER SCIENCE AND TECHNOLOGY, 2018, 77 (01) : 79 - 90