Reaction Dynamics and Solution Chemistry of Polyoxometalates by Electrospray Ionization Mass Spectrometry

被引:25
作者
Ohlin, C. Andre [1 ]
机构
[1] Monash Univ, Sch Chem, Clayton, Vic 3800, Australia
关键词
kinetics; mass spectrometry; polyoxometalates; OXYGEN-ISOTOPE EXCHANGE; IONS; COMPLEXES; RATES; WATER; FRAGMENTATION; CLUSTERS; ANIONS;
D O I
10.1002/asia.201100763
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Mass spectrometry both complements other analytical techniques and allows for types of analyses and experiments not possible with common analytical methods, such as NMR, IR, and UV/Vis spectroscopy. Electrospray constitutes one of the mildest forms of ionization, making it the preferred method for the analysis of large fragile or reactive ions. There is particular promise for mass spectrometry in aiding the characterization of polyoxometalates and their solutions, but caution must be taken in designing the experiments in order to yield reliable data and to avoid the temptation of over-interpreting the relevance of gas-phase data to solution chemistry.
引用
收藏
页码:262 / 270
页数:9
相关论文
共 52 条
[1]   Electrochemical Aspects of Electrospray and Laser Desorption/Ionization for Mass Spectrometry [J].
Abonnenc, Melanie ;
Qiao, Liang ;
Liu, BaoHong ;
Girault, Hubert H. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 3, 2010, 3 :231-254
[2]   ELECTROSPRAY MASS-SPECTROMETRY AS A TECHNIQUE FOR ELEMENTAL ANALYSIS - QUANTITATIVE ASPECTS [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (06) :649-654
[3]  
Antolasic F., WSEARCH32
[4]   Electrospray behavior of lacunary Keggin-type polyoxotungstates [XW11O39]p- (X = Si, P):: Mass spectrometric evidence for a concentration-dependent incorporation of an MOn+ (M = WVI, MoVI, VV) unit into the polyoxometalate vacancy [J].
Bonchio, M ;
Bortolini, O ;
Conte, V ;
Sartorel, A .
EUROPEAN JOURNAL OF INORGANIC CHEMISTRY, 2003, (04) :699-704
[5]   Application of electrospray ionisation mass spectrometry to the study of dilute aqueous oligomeric anions and their reactions [J].
Deery, MJ ;
Howarth, OW ;
Jennings, KR .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1997, (24) :4783-4788
[6]   Electrospray mass spectrometry (ESI-MS) in the study of metal-ligand solution equilibria [J].
Di Marco, VB ;
Bombi, GG .
MASS SPECTROMETRY REVIEWS, 2006, 25 (03) :347-379
[7]   Electrospray-ionization time-of-flight mass spectrometry: pH-dependence of phosphomolybdate species [J].
Easterly, CE ;
Hercules, DM ;
Houalla, M .
APPLIED SPECTROSCOPY, 2001, 55 (12) :1671-1675
[8]  
Geletii Y. V., 2008, ANGEW CHEM, V120, P3960
[9]   An all-inorganic, stable, and highly active tetraruthenium homogeneous catalyst for water oxidation [J].
Geletii, Yurii V. ;
Botar, Bogdan ;
Koegerler, Paul ;
Hillesheim, Daniel A. ;
Musaev, Djamaladdin G. ;
Hill, Craig L. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (21) :3896-3899
[10]   Polyoxometalates: Introduction to a class of inorganic compounds and their biomedical applications [J].
Hasenknopf, B .
FRONTIERS IN BIOSCIENCE-LANDMARK, 2005, 10 :275-287