Electromagnetic interference (EMI) damage to giant magnetoresistive (GMR) recording heads

被引:0
|
作者
Wallash, A [1 ]
Smith, D [1 ]
机构
[1] Quantum Chem Corp, Milpitas, CA 95035 USA
来源
ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS | 1998年
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
It is shown that giant magnetoresistive (GMR) recording heads can be damaged by electromagnetic interference (EMI) from a remote electrostatic discharge (ESD) event. An EMI test board is described and used to quantify EMI damage thresholds for a dipole or loop antenna attached to a GMR head. A practical example of EMI damage during resistance measurement is studied. SEM failure analysis after EMI testing shows melting damage to the GMR sensor that is similar in appearance to the damage caused by direct-contact ESD damage. It is concluded that it is important to control EMI during handling operations that involve any wires connected to the GMR recording head.
引用
收藏
页码:368 / 374
页数:7
相关论文
共 50 条
  • [1] Electromagnetic interference (EMI) damage to giant magnetoresistive (GMR) recording heads
    Wallash, A
    Smith, D
    ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS - 1998, 1998, : 368 - 374
  • [2] HDA-level ESD testing of giant magnetoresistive (GMR) recording heads
    Nordin, D
    ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS, 2000, 2000, : 205 - 210
  • [3] In-situ spin stand ESD testing of giant magnetoresistive (GMR) recording heads
    Wallash, A
    ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS, 2000, 2000, : 349 - 354
  • [4] Damage to magnetic recording heads due to electromagnetic interference
    Wallash, A
    Smith, D
    1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - SYMPOSIUM RECORD, VOLS 1 AND 2, 1998, : 834 - 836
  • [5] A study of diode protection for giant magnetoresistive recording heads
    Wallash, A
    Wang, WW
    JOURNAL OF ELECTROSTATICS, 2000, 49 (3-4) : 257 - 267
  • [6] Electrostatic discharge sensitivity of giant magnetoresistive recording heads
    Wallash, AJ
    Kim, YK
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) : 4921 - 4923
  • [7] A study of diode protection for giant magnetoresistive recording heads
    Wallash, A
    Wang, WW
    ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS, 1999, 1999, : 385 - 390
  • [8] Electromigration of GMR recording heads
    Luo, CP
    Kao, S
    Chang, JW
    MAGNETIC MATERIALS, PROCESSES, AND DEVICES VII AND ELECTRODEPOSITION OF ALLOYS, PROCEEDINGS, 2003, 2002 (27): : 515 - 523
  • [9] Reliability of GMR recording heads
    Luo, CP
    Kao, S
    Chang, JW
    MAGNETIC MATERIALS, PROCESSES, AND DEVICES VII AND ELECTRODEPOSITION OF ALLOYS, PROCEEDINGS, 2003, 2002 (27): : 524 - 531
  • [10] Electromagnetic Interference Effects on Stability of Tunneling Magnetoresistive Read Heads
    Khunkitti, Pirat
    Siritaratiwat, Apirat
    Kaewrawang, Arkom
    Kruesubthaworn, Anan
    IEEE MAGNETICS LETTERS, 2016, 7