Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine

被引:180
作者
Richter, M
Mattes, T
Cakir, B
机构
[1] Univ Ulm, Rehabil Krankenhaus Ulm, Orthopad Klin, Querschnittgelahmtenzentrum, D-89081 Ulm, Germany
[2] Univ Ulm, Dept Orthopaed, Ulm, Germany
关键词
computer-assisted surgery; cervical spine; posterior instrumentation; pedicle screws; transarticular screws; in vivo;
D O I
10.1007/s00586-003-0604-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Posterior instrumentation of the cervical spine has become increasingly popular in recent years. Dissatisfaction with lateral mass fixation, especially at the cervico-thoracic junction, has led spine surgeons to use pedicle screws. The improved biomechanical stability of pedicle screws and transarticular C1/2 screws allows for shorter instrumentations and improves the repositioning possibilities. Nevertheless, there are potential risks of iatrogenic damage to the spinal cord, nerve roots or the vertebral artery with both techniques. Therefore, the aim of this study was to evaluate whether C1/2 transarticular screws and transpedicular screws can be applied safely and with high accuracy in the cervical spine and the cervico-thoracic junction using a computer-assisted surgery system (CAS system). Posterior instrumentation was performed using the Brainlab VectorVision System (BrainLAB , Heimstetten, Germany) in 19 patients. Surface matching was used for registration. We placed 22 transarticular screws C1/2, 31 cervical pedicle screws, 10 high thoracic pedicle screws and one lateral mass screw C1. The screw position was evaluated postoperatively using CT with multiplanar reconstruction in the screw axis of each screw. None of the transarticular screws or pedicle screws was significantly (>2 mm) misplaced and no screw-related injury to vascular, neurogenic or bony structures was observed. No screw revision was necessary. The mean operation time was 144 min (90-240 min) and the mean blood loss was 234 ml (50-800 ml). C1/2 transarticular screws, as well as transpedicular screws in the cervical spine and the cervico-thoracic junction, can be applied safely and with high accuracy using a CAS system. Computer-assisted instrumentation is recommended especially for pedicle screws at C3-C6.
引用
收藏
页码:50 / 59
页数:10
相关论文
共 50 条
[41]   Accuracy of computer-assisted pedicle screw placement - An in vivo computed tomography analysis [J].
Schwarzenbach, O ;
Berlemann, U ;
Jost, B ;
Visarius, H ;
Arm, E ;
Langlotz, F ;
Nolte, LP ;
Ozdoba, C .
SPINE, 1997, 22 (04) :452-458
[42]   LOCATION OF TRANSPEDICULAR SCREWS FOR FIXATION OF THE LOWER THORACIC AND LUMBAR SPINE - COMPUTED-TOMOGRAPHY OF 45 FRACTURE CASES [J].
SIM, E .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (01) :28-32
[43]   Peroperative determination of safe superior transarticular screw trajectory through the lateral mass [J].
Solanki, GA ;
Crockard, HA .
SPINE, 1999, 24 (14) :1477-1482
[44]   PLACEMENT OF PEDICLE SCREWS IN THE THORACIC SPINE .2. AN ANATOMICAL AND RADIOGRAPHIC ASSESSMENT [J].
VACCARO, AR ;
RIZZOLO, SJ ;
BALDERSTON, RA ;
ALLARDYCE, TJ ;
GARFIN, SR ;
DOLINSKAS, C ;
AN, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (08) :1200-1206
[45]  
VACCARO AR, 1994, SPINE, V19, P2637
[46]   Modification of C1-C2 transarticular screw fixation by image-guided surgery [J].
Weidner, A ;
Wähler, M ;
Chiu, ST ;
Ullrich, CG .
SPINE, 2000, 25 (20) :2668-2673
[47]   SPINAL PEDICLE FIXATION - RELIABILITY AND VALIDITY OF ROENTGENOGRAM-BASED ASSESSMENT AND SURGICAL FACTORS ON SUCCESSFUL SCREW PLACEMENT [J].
WEINSTEIN, JN ;
SPRATT, KF ;
SPENGLER, D ;
BRICK, C ;
REID, S .
SPINE, 1988, 13 (09) :1012-1018
[48]   Frameless stereotactic guidance for surgery of the upper cervical spine [J].
Welch, WC ;
Subach, BR ;
Pollack, IF ;
Jacobs, GB .
NEUROSURGERY, 1997, 40 (05) :958-963
[49]  
Wilke H J, 1992, Eur Spine J, V1, P191, DOI 10.1007/BF00301312
[50]   The reliability of the lateral radiograph in determination of the optimal transarticular C1-C2 screw length [J].
Xu, RM ;
Ebraheim, NA ;
Misson, JR ;
Yeasting, RA .
SPINE, 1998, 23 (20) :2190-2194