Efficacy and Safety of Trans-nasal Sphenoid Ganglion Block in Obstetric Patients With Post-dural Puncture Headache: A Randomized Study

被引:4
|
作者
Nazir, Nazia [1 ]
Saxena, Anupriya [1 ]
Asthana, Unnati [2 ]
机构
[1] Govt Inst Med Sci, Anesthesiol & Crit Care, Greater Noida, India
[2] Employees State Insurance ESI Dent Coll & Hosp, Anesthesiol & Crit Care, New Delhi, India
关键词
visual analog scale; headache; epidural blood patch; post-dural puncture headache; sphenopalatine ganglion block; MANAGEMENT;
D O I
10.7759/cureus.20387
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction This study evaluated the efficacy and safety of two methods to achieve a trans-nasal sphenoid ganglion (SPG) block in obstetric patients for treating a post-dural puncture headache was evaluated. Methods In this prospective single-blinded randomized study, 20 enrolled patients were divided into two groups: group 1 (n=10) received SPG block via the applicator method and group 2 (n=10) by the nasal spray technique. The reduction in the pain score, number of patients requiring rescue analgesia with time to first analgesic request, repeat procedure required, and any adverse event were recorded. Results Patients in both groups were comparable with respect to the baseline characteristics. After the SPG block, the patients in group 1 had a significant reduction in the visual analog score (VAS) as compared to group 2 in the first 24 hours (P<0.001). Thereafter, the pain scores were comparable between the groups till discharge. Only one patient in group 1 required rescue analgesia as against six in group 2 (P=0.02, OR=13.5). The procedure was repeated in 10% of patients in group 1 and 30% of patients in group 2 (P=0.26, OR=3.85). On intragroup comparison, both groups revealed a significant reduction in pain from the baseline after the block (P<0.001). Conclusion The trans-nasal SPG block is a minimally invasive treatment option for post-dural puncture headache (PDPH) and avoids the need for more invasive treatment techniques. Among the two approaches of a transnasal SPG block, the applicator technique results in better pain relief.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Ropivacaine use in transnasal sphenopalatine ganglion block for post dural puncture headache in obstetric patients - case series
    Furtado, Ines
    de Lima, Isabel Flor
    Pedro, Sergio
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2018, 68 (04): : 421 - 424
  • [22] Lower incidence of post-dural puncture headache with spinal catheterization after accidental dural puncture in obstetric patients
    Verstraete, S.
    Walters, M. A.
    Devroe, S.
    Roofthooft, E.
    Van de Velde, M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2014, 58 (10) : 1233 - 1239
  • [23] Role of prednisolone in management of post-dural puncture headache after spinal anesthesia in obstetric patients
    Afridi, Nighat
    Fareed, Amna
    Fatima, Ambreen
    ANAESTHESIA PAIN & INTENSIVE CARE, 2019, 23 (02) : 168 - 171
  • [24] A ten-year retrospective study of post-dural puncture headache in 32,655 obstetric patients
    Costa, Ana C.
    Satalich, James
    Al-Bizri, Ehab
    Shodhan, Shivam
    Romeiser, Jamie L.
    Adsumelli, Rishimani
    Abola, Ramon E.
    Steinberg, Ellen S.
    Bennett-Guerrero, Elliott
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2019, 66 (12): : 1464 - 1471
  • [25] Nine-year audit of post-dural puncture headache in a tertiary obstetric hospital in Singapore
    Tien, J. C.
    Lim, M. J.
    Leong, W. L.
    Lew, E.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2016, 28 : 34 - 38
  • [26] Opioids for the Prevention of Post-dural Puncture Headache in Obstetrics: A Systematic Review and Meta-analysis of Efficacy and Safety
    Wu, Lan
    Chen, Shouming
    Jiang, Xiaoqin
    Cheng, Yan
    Zhang, Wensheng
    PAIN PHYSICIAN, 2021, 24 (07) : E1155 - U113
  • [27] Transnasal sphenopalatine ganglion block for the treatment of postdural puncture headache in obstetric patients
    Kent, Sheffield
    Mehaffey, Gregory
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 194 - 196
  • [28] Post-dural Puncture Headache in the Obstetric Patient: Needle Size, Number of Dural Puncture and Timing of Ambulation
    Rasooli, Sousan
    Moslemi, Farnaz
    Baybordi, Ali
    INTERNATIONAL JOURNAL OF WOMENS HEALTH AND REPRODUCTION SCIENCES, 2015, 3 (03): : 163 - 167
  • [29] Efficacy of Hyperbaric Oxygen Therapy in Post-Dural Puncture Headache
    Senol, Mehmet Gueney
    Kendirli, Mustafa Tansel
    Sen, Ahmet
    Karadurmus, Nuri
    Kendirli, Nurten
    Sen, Hueseyin
    Saracoglu, Mehmet
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2009, 29 (06): : 1618 - 1622
  • [30] Treatment of obstetric post-dural puncture headache. Part 1: conservative and pharmacological management
    Russell, R.
    Laxton, C.
    Lucas, D. N.
    Niewiarowski, J.
    Scrutton, M.
    Stocks, G.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2019, 38 : 93 - 103