High-Resolution 3D versus Standard-Resolution 2D T2-Weighted Turbo Spin Echo MRI for the Assessment of Lumbar Nerve Root Compromise

被引:8
|
作者
Sartoretti, Elisabeth [1 ,2 ]
Sartoretti, Thomas [1 ,2 ,3 ]
Schwenk, Arpad [1 ]
Alfieri, Alex [4 ]
Czell, David [2 ]
Wyss, Michael [5 ]
Wildi, Lukas [6 ]
Binkert, Christoph A. [1 ,2 ]
Sartoretti-Schefer, Sabine [1 ,2 ]
机构
[1] Kantonsspital Winterthur, Inst Radiol, Brauerstr 15, CH-8401 Winterthur, Switzerland
[2] Univ Zurich, Fac Med, CH-8006 Zurich, Switzerland
[3] Maastricht Univ, Maastricht Univ Med Ctr, Dept Radiol & Nucl Med, NL-6211 LK Maastricht, Netherlands
[4] Kantonsspital Winterthur, Inst Neurosurg, CH-8401 Winterthur, Switzerland
[5] Philips Hlth Syst, CH-8810 Zurich, Switzerland
[6] Kantonsspital Winterthur, Inst Rheumatol, CH-8401 Winterthur, Switzerland
关键词
spine; radiculopathy; magnetic resonance imaging; spinal nerve roots; acceleration; RADIOMICS; DIAGNOSIS;
D O I
10.3390/tomography8010020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiculopathy can be caused by nerve root irritation and nerve root compression at the level of the lateral recess or at the level of the intervertebral foramen. T2-weighted (T2w) MRI is considered essential to evaluate the nerve root and its course, starting at the lateral recess through the intervertebral foramen to the extraforaminal space. With the introduction of novel MRI acceleration techniques such as compressed SENSE, standard-resolution 2D T2w turbo spin echo (TSE) sequences with a slice-thickness of 3-4 mm can be replaced with high-resolution isotropic 3D T2w TSE sequences with sub-millimeter resolution without prolonging scan time. With high-resolution 3D MRI, the course of the nerve root can be visualized more precisely due to a detailed depiction of the anatomical situation and less partial volume effects, potentially allowing for a better detection of nerve root compromise. In this intra-individual comparison study, 55 patients with symptomatic unilateral singular nerve root radiculopathy underwent MRI with both 2D standard- and 3D high-resolution T2w TSE MRI sequences. Two readers graded the degree of lumbar lateral recess stenosis and lumbar foraminal stenosis twice on both image sets using previously validated grading systems in an effort to quantify the inter-readout and inter-sequence agreement of scores. Inter-readout agreement was high for both grading systems and for 2D and 3D imaging (Kappa = 0.823-0.945). Inter-sequence agreement was moderate for both lumbar lateral recess stenosis (Kappa = 0.55-0.577) and lumbar foraminal stenosis (Kappa = 0.543-0.572). The percentage of high degree stenosis with nerve root deformity increased from 16.4%/9.8% to 41.8-43.6%/34.1% from 2D to 3D images for lateral recess stenosis/foraminal stenosis, respectively. Therefore, we show that while inter-readout agreement of grading systems is high for both standard- and high-resolution imaging, the latter outperforms standard-resolution imaging for the visualization of lumbar nerve root compromise.
引用
收藏
页码:257 / 266
页数:10
相关论文
共 50 条
  • [1] High-resolution 3D T2-weighted fast spin echo: new applications in the orbit
    Simon, EM
    McCaffery, S
    Rowley, HA
    Fischbein, NJ
    Shimikawa, A
    O'Brien, JM
    NEURORADIOLOGY, 2003, 45 (07) : 489 - 492
  • [2] High-resolution 3D T2-weighted fast spin echo: new applications in the orbit
    Erin M. Simon
    Sharon McCaffery
    Howard A. Rowley
    Nancy J. Fischbein
    Ann Shimikawa
    Joan M. O'Brien
    Neuroradiology, 2003, 45 : 489 - 492
  • [3] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Lv, Peng
    Dai, Yuanyuan
    Lin, Jiang
    Zhang, Weisheng
    Liu, Hao
    Liu, Hui
    Tang, Xiao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03) : 395 - 400
  • [4] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Peng Lv
    Yuanyuan Dai
    Jiang Lin
    Weisheng Zhang
    Hao Liu
    Hui Liu
    Xiao Tang
    The International Journal of Cardiovascular Imaging, 2017, 33 : 395 - 400
  • [5] Diagnosis of Nerve Root Compromise of the Lumbar Spine: Evaluation of the Performance of Three-dimensional Isotropic T2-weighted Turbo Spin-Echo SPACE Sequence at 3T
    Sung, Jinkyeong
    Jee, Won-Hee
    Jung, Joon-Yong
    Jang, Jinhee
    Kim, Jin-Sung
    Kim, Young-Hoon
    Ha, Kee-Yong
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (01) : 249 - 259
  • [6] MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T
    Lee, Sungwon
    Jee, Won-Hee
    Jung, Joon-Yong
    Lee, So-Yeon
    Ryu, Kyeung-Sik
    Ha, Kee-Yong
    ACTA RADIOLOGICA, 2015, 56 (02) : 174 - 181
  • [7] Uterine Tumors: Comparison of 3D versus 2D T2-weighted Turbo Spin-Echo MR Imaging at 3.0 T-Initial Experience
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Ueguchi, Takashi
    Tatsumi, Mitsuaki
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Tomoda, Kaname
    Tomiyama, Noriyuki
    RADIOLOGY, 2011, 258 (01) : 154 - 163
  • [8] MRI of the anterior talofibular ligament, talar cartilage and os subfibulare: Comparison of isotropic resolution 3D and conventional 2D T2-weighted fast spin-echo sequences at 3.0 T
    Yi, Jisook
    Cha, Jang Gyu
    Lee, Young Koo
    Lee, Bo Ra
    Jeon, Chan Hong
    SKELETAL RADIOLOGY, 2016, 45 (07) : 899 - 908
  • [9] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41
  • [10] Automatic zonal segmentation of the prostate from 2D and 3D T2-weighted MRI and evaluation for clinical use
    Hamzaoui, Dimitri
    Montagne, Sarah
    Renard-Penna, Raphaele
    Ayache, Nicholas
    Delingette, Herve
    JOURNAL OF MEDICAL IMAGING, 2022, 9 (02) : 24001