Dose distribution measurements and calculations for Dounreay hot particles

被引:7
作者
Aydarous, A. Sh. [1 ]
Charles, M. W. [2 ]
Darley, P. J. [2 ]
机构
[1] Taif Univ, Dept Phys, Al Hawiah, Taif, Saudi Arabia
[2] Univ Birmingham, Sch Phys & Astron, Birmingham B15 2TT, W Midlands, England
关键词
D O I
10.1093/rpd/ncm328
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Discrete fragments of irradiated nuclear fuel have been discovered on the foreshore at the Dounreay nuclear site in Scotland, offshore on the seabed and at nearby beaches which have public access. The fragments contain mainly (137)Cs and (90)Sr/(90)Y and for particles recovered to date, (137)Cs activities are within the range of 10(3) to 10(8) Bq. The most active particles found at Sandside Beach contain similar to 3x10(5)Bq (137)Cs. Direct measurements of the spatial dose distributions from 37 fuel fragments were measured in detail for the first time using radiochromic dye film as part of a national evaluation of the associated potential radiological hazard. Monte Carlo code calculations of the doses are in good agreement with measurements, taking into account variations to be expected due to differences in shape and the increasing importance of self-absorption for the larger, more active fragments. Dose measurements provide little evidence for wide variations in the (137)Cs:(90)Sr/(90)Y ratio between fragments. Specific attention is given to the evaluation of skin dose, averaged over an area of 1 cm(2) at a depth of 0.07 mm, since this is of major radiological concern. There is no obvious dependence of skin dose on the site of origin of the fragments (foreshore, seabed or beaches) for a given (137)Cs activity level. A dose rate survey instrument (SmartION) was shown to provide a rapid and convenient method for skin dose assessment from fuel fragments in the (137)Cs activity range measured (2x10(5) to 2x10(7) Bq). A conversion factor multiplier of 240 can be applied to the open window SmartION scale reading to estimate the skin dose rate within +/- 25%.
引用
收藏
页码:146 / 158
页数:13
相关论文
共 28 条
[1]  
[Anonymous], [No title captured]
[2]   Development of an ICCD-scintillator system for measurement of spatial dose distributions around 'hot particles' [J].
Aydarous, AS ;
Darley, PJ ;
Charles, MW .
RADIATION PROTECTION DOSIMETRY, 2004, 108 (04) :317-326
[3]   A wide dynamic range, high-spatial-resolution scanning system for radiochromic dye films [J].
Aydarous, AS ;
Darley, PJ ;
Charles, MW .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :1379-1389
[4]  
AYDAROUS AS, 2003, THESIS U BIRMINGHAM
[5]  
BRIESMEISTER JF, 1997, GEN MONTE CARLO CODE
[6]  
BRIESMEISTER JF, 2000, GEN MONTE CARLO N PA
[7]  
BURGESS PH, 2001, NRPBR326
[8]  
Charles M., 2005, PROC 7 INT S SOC RAD, P23
[9]  
CHARLES MW, 1999, P 11 INT C RAD RES D, V2, P807
[10]  
Darley PJ, 2003, RADIAT PROT DOSIM, V105, P49, DOI 10.1093/oxfordjournals.rpd.a006288