The effects of prosthetic foot design on physiologic measurements, self-selected walking velocity, and physical activity in people with transtibial amputation

被引:82
作者
Hsu, MJ
Nielsen, DH
Lin-Chan, SJ
Shurr, D
机构
[1] Natl Yang Ming Univ, Inst & Fac Phys Therapy, Taipei 112, Taiwan
[2] Univ Iowa, Grad Program Phys Therapy & Rehabil Sci, Iowa City, IA USA
[3] Texas Womans Univ, Sch Phys Therapy, Dallas, TX USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2006年 / 87卷 / 01期
关键词
amputation; heart rate; oxygen consumption; physical fitness; prostheses and implants; prosthesis design; rehabilitation;
D O I
10.1016/j.apmr.2005.07.310
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate the physiologic differences during multispeed treadmill walking and physical activity profiles for the Otto Bock C-Walk foot (C-Walk), Flex-Foot, and solid ankle cushion heel (SACH) foot in people with transtibial amputation. Design: A repeated-measures design with 3 prostheses. Setting: Research laboratory. Participants: Eight men with unilateral transtibial amputation. Interventions: Not applicable. Main Outcome Measures: Physiologic responses (energy expenditure, gait efficiency, exercise intensity, rating of perceived exertion [RPE]) during multispeed treadmill walking (53.64, 67.05, 80.46, 93.87, 107.28m/rnin) test were analyzed with 2-way repeated-measures analysis of variance (ANOVA). One-way ANOVA was employed to analyze foot-type differences for self-selected walking velocity (SSWV), and steps per day (daily activity). Analysis of covariance was used to analyze foot-type differences with SSWV as the covariable for the physiologic measurements. Results: The C-Walk had a trend of improved physiologic responses compared with the SACH; however, no foot-type differences were statistically significant. Compared with the C-Walk and SACH, the Flex-Foot showed no significant differences in energy expenditure and gait efficiency, but significantly lower percentage of age-predicted maximum heart rate and RPE values. Conclusions: The energy storing-releasing feet appeared to have certain trends of improved gait performance compared with the SACH; however, not many objective foot-type differences were significantly noted. Further studies with a larger sample size are suggested.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 30 条
  • [1] Accuracy of five electronic pedometers for measuring distance walked
    Bassett, DR
    Ainsworth, BE
    Leggett, SR
    Mathien, CA
    Main, JA
    Hunter, DC
    Duncan, GE
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) : 1071 - 1077
  • [2] VALIDATION OF A SIMPLE MECHANICAL ACCELEROMETER (PEDOMETER) FOR THE ESTIMATION OF WALKING ACTIVITY
    BASSEY, EJ
    DALLOSSO, HM
    FENTEM, PH
    IRVING, JM
    PATRICK, JM
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1987, 56 (03): : 323 - 330
  • [3] BREAKEY J, 1976, ORTHOTICS PROSTHET, V30, P17
  • [4] CULHAM EG, 1986, PROSTHET ORTHOT INT, V10, P15
  • [5] DAY HJB, 1981, PROSTHET ORTHOT INT, V5, P23
  • [6] FISHER SV, 1978, ARCH PHYS MED REHAB, V59, P124
  • [7] Eating control and physical activity as determinants of short-term weight maintenance after a very-low-calorie diet among obese women
    Fogelholm, M
    Kukkonen-Harjula, K
    Oja, P
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 1999, 23 (02) : 203 - 210
  • [8] COMPARISON BETWEEN ARM AND LEG EXERCISE IN WOMEN AND MEN
    FREYSCHUSS, U
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1975, 35 (08) : 795 - 800
  • [9] Affective and metabolic responses to hypnosis, autogenic relaxation, and quiet rest in the supine and seated positions
    Garvin, AW
    Trine, MR
    Morgan, WP
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL HYPNOSIS, 2001, 49 (01) : 5 - +
  • [10] Hafner BJ, 2002, J REHABIL RES DEV, V39, P1