Study on the measurement accuracy of an improved cemented carbide orifice flowmeter in natural gas pipeline

被引:19
作者
Dong, Jingya [1 ,2 ]
Jing, Chengjun [3 ]
Peng, Yang [4 ]
Liu, Yang [4 ]
Ren, Hongyu [5 ]
Liu, Xianxu [6 ]
机构
[1] Sichuan Univ, Inst Disaster Management & Reconstruct, Chengdu 610207, Sichuan, Peoples R China
[2] Southwest Petr Univ, Sch Engn, Nanchong 637001, Peoples R China
[3] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Sichuan, Peoples R China
[4] PetroChina Southwest Oil & Gas Field Co, Gas Management Off, Chengdu 610215, Sichuan, Peoples R China
[5] Petrochina Southwest Pipeline Co, Chengdu 610000, Sichuan, Peoples R China
[6] Chengdu Li Chuang Mold Ltd Co, Chengdu 610213, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Natural gas pipeline; Standard orifice flowmeter; Cemented carbide; Stainless steel; Discharge coefficient; Measurement accuracy; SLOTTED ORIFICE; WET GAS; V-CONE; FLOW-THROUGH; PLATE; METER; PERFORMANCE; SIMULATION;
D O I
10.1016/j.flowmeasinst.2017.12.008
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Standard orifice flowmeter has been widely used in the field of natural gas metering. However, the traditional stainless steel orifice flowmeter (TSSOF) is not resistant to wear and corrosion, especially the entrance sharpness will gradually increase. In order to improve the measurement accuracy and working life of the orifice flowmeter, the cemented carbide is embedded in the opening place of the TSSOF, thus, an improved carbide orifice flow meter (ICOF) is manufactured. For conducting the field comparison experiment, four ICOF and four TSSOF were installed in four natural gas pipelines, respectively. The experiment results show that the variation ranges of the entrance sharpness of them are 9.863-26.438 mu m and 9.192-57.329 mu m, respectively; the entrance sharpness is increased with the increasing of the use time, but the change rate of the ICOF is smaller. The CFD simulation was also carried out. The simulated discharge coefficient values were compared with the calculated discharge coefficient values by the ISO empirical correlation. The results show that the accuracy of the two types of orifice flowmeter display a same decreasing trend with the increasing of the use time, and the absolute value of the relative error ranges are 0.51-2.28%, 0.13-4.25%, respectively, but the descent rate of the ICOF is smaller; the measurement accuracy of the ICOF is improved up to 2.39 times compared with the TSSOF, and it is more stable when the gas flow rate changes in the pipeline. Additionally, the effect of downstream inclination angle was studied. The result demonstrate that the measurement accuracy can be improved by 0.34%, when the downstream inclination angle is 60 degrees at the gas flow rate of 5-15 m/s, which is superior to the commonly used inclination angle of 45 degrees In summary, the ICOF can be better applied to engineering practice.
引用
收藏
页码:52 / 62
页数:11
相关论文
共 39 条
[1]  
Abou El-Azm Aly A, 2010, EXPT THERMAL FLUID S, V34, P111
[2]   Characterization of flow homogeneity downstream of a slotted orifice plate in a two-phase flow using electrical resistance tomography [J].
Annamalai, Gautham ;
Pirouzpanah, Sahand ;
Gudigopuram, Sujan R. ;
Morrison, Gerald L. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2016, 50 :209-215
[3]  
[Anonymous], 2008, 214462008 GBT
[4]  
[Anonymous], 2003, 5167 ISO 2
[5]   Investigation of flow through multi-stage restricting orifices [J].
Araoye, Abdulrazaq A. ;
Badr, Hasan M. ;
Ahmed, Wael H. .
ANNALS OF NUCLEAR ENERGY, 2017, 104 :75-90
[6]  
Barry J.J., 1992, NUMERICAL SIMULATION
[7]  
Beitler S.R., 1935, ENG EXPT STATION B, V89
[8]  
Deng Y., 1992, CHINESE GAS PLANNING
[9]   Time resolved measurement of pulsating flow using orifices [J].
Doblhoff-Dier, K. ;
Kudlaty, K. ;
Wiesinger, M. ;
Groeschl, M. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2011, 22 (02) :97-103
[10]  
Dong J.Y., 2015, OIL GAS FIELD SURF E, V34, P83