Three-dimensional, non-destructive visualization of vertical root fractures using flat panel volume detector computer tomography:: an ex vivo in vitro case report

被引:45
作者
Hannig, C
Dullin, C
Hülsmann, M
Heidrich, G
机构
[1] Univ Gottingen, Dept Operat Dent Prevent Dent & Periodontol, D-37075 Gottingen, Germany
[2] Univ Gottingen, Dept Diagnost Radiol, D-37075 Gottingen, Germany
关键词
diagnosis; flat panel volume detector computer tomography; root canal anatomy; three-dimensional observation; vertical root fractures;
D O I
10.1111/j.1365-2591.2005.01033.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To detect and to visualize radiographically vertical root fractures in extracted teeth with a prototype of a novel, high resolution, three-dimensional flat panel volume detector computer tomograph (FD-VCT) system. Summary Five teeth with root fillings and clinical symptoms such as fistulas and isolated periodontal pockets of 8 mm or more were extracted after dental radiography indicating lateral or periapical lesions. Vertical root fractures or cracks were suspected because of the symptoms and clinical findings were evident after extraction in all cases but fracture lines were not visible on routine dental radiographs acquired before extraction. The extracted teeth were explored with a prototype of a FD-VCT. Using the FD-VCT, in all cases vertical root fractures or crack lines could be detected clearly in different views, depiction-modes and cross-sections at a spatial resolution of 140 mu m. The evaluation of the fracture lines and teeth could be performed in three-dimensional views. The FD-VCT findings were confirmed by detailed inspection of the extracted teeth. Key learning points The FD-VCT is an innovative diagnostic tool for non-destructive, three-dimensional evaluation of extracted teeth in pre-clinical and experimental studies. The FD-VCT allows precise visualization and evaluation of vertical root fractures or cracks in extracted teeth. Clinical application of the system may be possible if technical modifications reduce the exposure dose: the high resolution detector systems of the FD-VCT should be combined with radiation systems that focus the radiation to the area of interest.
引用
收藏
页码:904 / 913
页数:10
相关论文
共 23 条
[1]   STRAY-FIELD IMAGING (STRAFI) OF TEETH [J].
BAUMANN, MA ;
DOLL, GM ;
ZICK, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1993, 75 (04) :517-522
[2]   Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine - An in vitro study [J].
Fortin, T ;
Champleboux, G ;
Bianchi, S ;
Buatois, H ;
Coudert, FL .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (06) :651-656
[3]  
Fuhrmann A, 2003, Int J Comput Dent, V6, P129
[4]  
FUSS Z, 1999, INT ENDOD J, V32, P83
[5]  
HEIDRICH G, 2005, IN PRESS FORTSCHRITT
[6]   Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis [J].
Kiessling, F ;
Greschus, S ;
Lichy, MP ;
Bock, M ;
Fink, C ;
Vosseler, S ;
Moll, J ;
Mueller, MM ;
Fusenig, NE ;
Traupe, H ;
Semmler, W .
NATURE MEDICINE, 2004, 10 (10) :1133-1138
[7]   NMR MICROSCOPY - FUNDAMENTALS, LIMITS AND POSSIBLE APPLICATIONS [J].
KUHN, W .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1990, 29 (01) :1-19
[8]   MAGNETIC-RESONANCE-IMAGING OF HUMAN TEETH [J].
LOCKHART, PB ;
KIM, SC ;
LUND, NL .
JOURNAL OF ENDODONTICS, 1992, 18 (05) :237-244
[9]   DIAGNOSIS AND POSSIBLE CAUSES OF VERTICAL ROOT FRACTURES [J].
MEISTER, F ;
LOMMEL, TJ ;
GERSTEIN, H .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1980, 49 (03) :243-253
[10]   Effect of iterative restoration on the detection of artificially induced vertical radicular fractures by Tuned Aperture Computed Tomography [J].
Nair, MK ;
Lic, O ;
Gröndahl, HG ;
Webber, RL ;
Nair, UP ;
Wallace, JA .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2003, 96 (01) :118-125