Aortic valve calcification scoring with computed tomography: impact of iterative reconstruction techniques

被引:7
作者
Hinzpeter, Ricarda [1 ]
Weber, Lucas [1 ]
Euler, Andre [1 ]
Kasel, Albert M. [2 ]
Tanner, Felix C. [2 ]
Alkadhi, Hatem [1 ]
Eberhard, Matthias [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Univ Hosp Zurich, Univ Heart Ctr Zurich, Dept Cardiol, Zurich, Switzerland
关键词
Aortic stenosis; Transcatheter aortic valve replacement; Computed tomography; Iterative reconstruction; EUROPEAN ASSOCIATION; CALCIUM SCORES; DOSE REDUCTION; CT; STENOSIS; SOCIETY; DISEASE;
D O I
10.1007/s10554-020-01862-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To investigate whether image reconstruction with iterative reconstruction (IR) affects aortic valve calcification (AVC) scoring and likelihood categorization of severe aortic stenosis (AS). In this IRB-approved retrospective study, we included 100 consecutive patients with AS (40 females; mean age 77 +/- 10 years; age range: 36-99 years) undergoing CT prior to transcatheter aortic valve replacement. Non-enhanced, electrocardiography-gated CT of the heart was reconstructed with filtered back projection (FBP) and with advanced modeled IR at strength levels 1-5. AVC Agatston scores were calculated and gender-specific cut-off values for AS likelihood categorization were applied according to current European Society of Cardiology recommendations (from unlikely to very likely). Friedman test with post-hoc Bonferroni correction was applied to analyze interval- and ordinal-scaled data. Compared to FBP, each IR strength level produced significantly different AVC Agatston scores (p < 0.001-0.002). Median AVC Agatston score for image reconstruction with FBP was 2527 (IQR: 1711-3663) and decreased with increasing IR strength levels up to 2281 (IQR: 1471-3357) at strength level 5. Likelihood categorization of severe AS was significantly different among image reconstruction algorithms (p < 0.001). Image reconstruction with IR strength level 5 led to a downward shift of likelihood categorization in 28 patients (28%) compared to images reconstructed with FBP. IR significantly impacts AVC scoring with significantly decreasing AVC scores with increasing IR strength levels. This leads to relevant changes in likelihood categorization of patients with severe AS., leading to underestimation of severe AS.
引用
收藏
页码:1575 / 1581
页数:7
相关论文
共 21 条
[1]  
Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
[2]  
Baumgartner H, 2017, J AM SOC ECHOCARDIOG, V30, P372, DOI [10.1093/ehjci/jew335, 10.1016/j.echo.2017.02.009]
[3]   Echocardiographic discrepancies in severity grading of aortic valve stenosis with left ventricular outflow tract (LVOT) cut-off values in an Asian population [J].
Chew, Nicholas W. S. ;
Ngiam, Jinghao Nicholas ;
Tan, Benjamin Yong-Qiang ;
Sia, Ching-Hui ;
Sim, Hui Wen ;
Kuntjoro, Ivandito ;
Kong, William K. F. ;
Tay, Edgar L. W. ;
Yeo, Tiong-Cheng ;
Poh, Kian Keong .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (04) :615-621
[4]   Impact of Aortic Valve Calcification, as Measured by MDCT, on Survival in Patients With Aortic Stenosis [J].
Clavel, Marie-Annick ;
Pibarot, Philippe ;
Messika-Zeitoun, David ;
Capoulade, Romain ;
Malouf, Joseph ;
Aggarval, Shivani ;
Araoz, Phillip A. ;
Michelena, Hector I. ;
Cueff, Caroline ;
Larose, Eric ;
Miller, Jordan D. ;
Vahanian, Alec ;
Enriquez-Sarano, Maurice .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (12) :1202-1213
[5]   The Complex Nature of Discordant Severe Calcified Aortic Valve Disease Grading New Insights From Combined Doppler Echocardiographic and Computed Tomographic Study [J].
Clavel, Marie-Annick ;
Messika-Zeitoun, David ;
Pibarot, Philippe ;
Aggarwal, Shivani R. ;
Malouf, Joseph ;
Araoz, Phillip A. ;
Michelena, Hector I. ;
Cueff, Caroline ;
Larose, Eric ;
Capoulade, Romain ;
Vahanian, Alec ;
Enriquez-Sarano, Maurice .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (24) :2329-2338
[6]   Measurement of aortic valve calcification using multislice computed tomography: correlation with haemodynamic severity of aortic stenosis and clinical implication for patients with low ejection fraction [J].
Cueff, Caroline ;
Serfaty, Jean-Michel ;
Cimadevilla, Claire ;
Laissy, Jean-Pierre ;
Himbert, Dominique ;
Tubach, Florence ;
Duval, Xavier ;
Iung, Bernard ;
Enriquez-Sarano, Maurice ;
Vahanian, Alec ;
Messika-Zeitoun, David .
HEART, 2011, 97 (09) :721-726
[7]   Reproducibility of aortic valve calcification scoring with computed tomography - An interplatform analysis [J].
Eberhard, M. ;
Hinzpeter, R. ;
Polacin, M. ;
Morsbach, F. ;
Maisano, F. ;
Nietlispach, F. ;
Nguyen-Kim, T. D. L. ;
Tanner, F. C. ;
Alkadhi, H. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (02) :92-98
[8]   Quantification of aortic valve calcification on contrast-enhanced CT of patients prior to transcatheter aortic valve implantation [J].
Eberhard, Matthias ;
Mastalerz, Monika ;
Frauenfelder, Thomas ;
Tanner, Felix C. ;
Maisano, Francesco ;
Nietlispach, Fabian ;
Seifert, Burkhardt ;
Alkadhi, Hatem ;
Thi Dan Linh Nguyen-Kim .
EUROINTERVENTION, 2017, 13 (08) :921-927
[9]   Aortic Stenosis in Cancer Survivors After Chest Radiation [J].
Flachskampf, Frank A. .
JACC-CARDIOVASCULAR IMAGING, 2018, 11 (08) :1081-1083
[10]   Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography [J].
Gordic, Sonja ;
Desbiolles, Lotus ;
Sedlmair, Martin ;
Manka, Robert ;
Plass, Andre ;
Schmidt, Bernhard ;
Husarik, Daniela B. ;
Maisano, Francesco ;
Wildermuth, Simon ;
Alkadhi, Hatem ;
Leschka, Sebastian .
EUROPEAN RADIOLOGY, 2016, 26 (02) :459-468