Constrained Estimation of the Arterial Input Function for Myocardial Perfusion Cardiovascular Magnetic Resonance

被引:11
作者
Fluckiger, Jacob U. [1 ]
Schabel, Matthias C. [1 ]
DiBella, Edward V. R. [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84132 USA
关键词
pharmacokinetics; myocardial perfusion imaging; contrast-enhanced MRI; BLIND ESTIMATION; BLOOD-FLOW; MRI; QUANTIFICATION; MODEL; ACQUISITION; PARAMETERS; VOLUME;
D O I
10.1002/mrm.22809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate quantification of myocardial perfusion remains challenging due to saturation of the arterial input function at high contrast concentrations. A method for estimating the arterial input function directly from tissue curves in the myocardium that avoids these difficulties is presented. In this constrained alternating minimization with model (CAMM) algorithm, a portion of the left ventricular blood pool signal is also used to constrain the estimation process. Extensive computer simulations assessing the accuracy of kinetic parameter estimation were performed. In 5000 noise realizations, the use of the AIF given by the estimation method returned kinetic parameters with mean K-trans error of -2% and mean k(ep) error of 0.4%. Twenty in vivo resting perfusion datasets were also processed with this method, and pharmacokinetic parameter values derived from the blind AIF were compared with those derived from a dual-bolus measured AIF. For 17 of the 20 datasets, there were no statistically significant differences in K-trans estimates, and in aggregate the kinetic parameters were not significantly different from the dual-bolus method. The cardiac constrained alternating minimization with model method presented here provides a promising approach to quantifying perfusion of myocardial tissue with a single injection of contrast agent and without a special pulse sequence though further work is needed to validate the approach in a clinical setting. Magn Reson Med 66:419427, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 25 条
[1]   Temporally constrained reconstruction of dynamic cardiac perfusion MRI [J].
Adluru, Ganesh ;
Awate, Suyash P. ;
Tasdizen, Tolga ;
Whitaker, Ross T. ;
DiBella, Edward V. R. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1027-1036
[2]  
[Anonymous], J MAGN RESON IMAGING
[3]  
AXEL L, 2006, P ISMRM 14 SCI M EXH, P3566
[4]  
BALACHANDRASEKA.A, 2008, P ISMRM 16 SCI M EXH, P3051
[5]   INFLUENCE OF BOLUS VOLUME AND DOSE OF GADOLINIUM CHELATE FOR FIRST-PASS MYOCARDIAL PERFUSION MR-IMAGING STUDIES [J].
CANET, E ;
DOUEK, P ;
JANIER, M ;
BENDID, K ;
AMAYA, J ;
MILLET, P ;
REVEL, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04) :411-415
[6]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[7]   Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: Comparison to single-bolus injection method [J].
Christian, Timothy F. ;
Aletras, Anthony H. ;
Arai, Andrew E. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) :1271-1277
[8]  
Di Bella EVR, 1999, PHYS MED BIOL, V44, P765, DOI 10.1088/0031-9155/44/3/018
[9]   Improving MR quantification of regional blood volume with intravascular T-1 contrast agents: Accuracy, precision, and water exchange [J].
Donahue, KM ;
Weisskoff, RM ;
Chesler, DA ;
Kwong, KK ;
Bogdanov, AA ;
Mandeville, JB ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :858-867
[10]  
Feng D, 1997, IEEE Trans Inf Technol Biomed, V1, P243, DOI 10.1109/4233.681168