Agreement of Corrected Intraocular Pressure Values Between Corvis ST and Pentacam in Patients With Keratoconus, Subclinical Keratoconus, and Normal Cornea

被引:7
|
作者
Chen, Yanhui
Rong, Hua
Liu, Wei
Liu, Guihua
Du, Bei
Jin, Chengcheng
Wei, Ruihua [1 ,2 ]
机构
[1] Tianjin Med Univ Eye Hosp, Tianjin Int Joint Res & Dev Ctr Ophthalmol & Vis, Eye Inst, 251 Fukang Rd, Tianjin, Peoples R China
[2] Tianjin Med Univ Eye Hosp, Sch Optometry, 251 Fukang Rd, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
keratoconus; subclinical keratoconus; corneal biomechanics; biomechanically corrected IOP; CCT-corrected IOP; TRANSEPITHELIAL PHOTOREFRACTIVE KERATECTOMY; BIOMECHANICAL PROPERTIES; RESPONSE PARAMETERS; CROSS-LINKING; THICKNESS; TONOMETRY; INTEGRATION; ECTASIA;
D O I
10.1097/ICO.0000000000002707
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the agreement of corrected intraocular pressure (IOP) values between Corvis ST (Delta IOP1) and Pentacam (Delta IOP2) in patients with keratoconus (KC), subclinical KC (sub-KC), and normal cornea. Methods: In total, 235 eyes were divided into KC, sub-KC, and control groups. Differences in Delta IOP1 (biomechanically corrected IOP minus uncorrected IOP) and Delta IOP2 (central corneal thickness-corrected amounts of IOP) were analyzed within and among groups. Topographical and biomechanical differences were compared among the 3 groups. Factors affecting differences between Delta IOP1 and Delta IOP2 were analyzed. Agreement analysis of Delta IOP2 and Delta IOP1 was performed by Bland-Altman plots for all 3 groups. Results: Mean Delta IOP1 was highest in the KC group (1.23 +/- 0.84 mm Hg), followed by sub-KC and control groups (all P < 0.05). Deformation amplitude ratio at 2 mm (DA-2 mm), integrated radius, stiffness parameter at first applanation, and Corvis biomechanical index values significantly differed between sub-KC and control groups. The differences between Delta IOP1 and Delta IOP2 were affected by stiffness parameter at first applanation, after adjusting for central corneal thickness and age, in all 3 groups. The lowest agreement between Delta IOP2 and Delta IOP1 was observed in the KC group (mean difference: 1.90 mm Hg; 95% limit of agreement ranged from -0.2 to 3.9 mm Hg). Conclusions: Among the 3 groups in this study, the KC group exhibited the worst consistency between Delta IOP2 and Delta IOP1. For the sub-KC and control groups, corrected IOP values derived by Pentacam were similar to Corvis ST. Ophthalmologists should carefully consider the mechanical properties of eyes with KC during IOP management.
引用
收藏
页码:1426 / 1432
页数:7
相关论文
共 6 条
  • [1] Pentacam Scheimpflug Tomography Findings in Topographically Normal Patients and Subclinical Keratoconus Cases
    Ruiseor Vazquez, Pablo R.
    David Galletti, Jonatan
    Minguez, Natalia
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfortner, Tomas
    Gaston Galletti, Jeremias
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (01) : 32 - 40
  • [2] Evaluation of Intraocular Pressure and Other Biomechanical Parameters to Distinguish between Subclinical Keratoconus and Healthy Corneas
    Peris-Martinez, Cristina
    Diez-Ajenjo, Maria Amparo
    Garcia-Domene, Maria Carmen
    Pinazo-Duran, Maria Dolores
    Luque-Cobija, Maria Jose
    del Buey-Sayas, Maria angeles
    Orti-Navarro, Susana
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [3] Relationship between corneal biomechanical parameters and corneal sublayer thickness measured by Corvis ST and UHR-OCT in keratoconus and normal eyes
    Li, Yong
    Xu, Zhiqiang
    Liu, Qiaoli
    Wang, Yuzhou
    Lin, Kan
    Xia, Jiahui
    Chen, Shihao
    Hu, Liang
    EYE AND VISION, 2021, 8 (01)
  • [4] A Comparison of the Corrected Intraocular Pressure Obtained by the Corvis ST and Reichert 7CR Tonometers in Glaucoma Patients
    Nakao, Yoshitaka
    Kiuchi, Yoshiaki
    Okimoto, Satoshi
    PLOS ONE, 2017, 12 (01):
  • [5] Relationship between corneal biomechanical parameters and corneal sublayer thickness measured by Corvis ST and UHR-OCT in keratoconus and normal eyes
    Yong Li
    Zhiqiang Xu
    Qiaoli Liu
    Yuzhou Wang
    Kan Lin
    Jiahui Xia
    Shihao Chen
    Liang Hu
    Eye and Vision, 8
  • [6] Comparison of Biomechanically Corrected Intraocular Pressure Obtained by Corvis ST and Goldmann Applanation Tonometry in Patients With Open-angle Glaucoma and Ocular Hypertension
    Ye, Yiming
    Yang, Yangfan
    Fan, Yanmei
    Lan, Min
    Yu, Keming
    Yu, Minbin
    JOURNAL OF GLAUCOMA, 2019, 28 (10) : 922 - 928