Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch

被引:19
|
作者
Kim, Hyo-Hyun [1 ]
Lee, Sak [1 ]
Joo, Hyun-Chel [1 ]
Kim, Jung-Hwan [1 ]
Youn, Young-Nam [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Seung-Hyun [1 ]
机构
[1] Yonsei Univ, Yonsei Univ Hlth Syst, Severance Cardiovasc Hosp, Div Cardiovasc Surg,Coll Med, 250 Seongsanno, Seoul 03722, South Korea
来源
ANNALS OF THORACIC SURGERY | 2020年 / 109卷 / 03期
关键词
HEMODYNAMIC PERFORMANCE; MORTALITY;
D O I
10.1016/j.athoracsur.2019.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Many variables may affect the hemodynamic performance of the aortic valve prosthesis, and suture technique remains an important factor for determining maximum valve performance. The objective of this study was to determine the suture technique that produces better hemodynamic performance for aortic valve replacement (AVR). Methods. Patients who underwent AVR between January 2015 and September 2018 in our institution were analyzed. We compared the preoperative clinical information and 1-year postoperative hemodynamic data of interrupted pledget mattress sutures (pledgeted group), interrupted nonpledget mattress sutures (nonpledgeted group), and figure-of-8 nonpledget sutures (figure-of-eight group). We compared the incidence of prosthesis-patient mismatch (PPM) and cardiac adverse events among the groups and subanalyzed the PPM rate in a small aortic annulus (18 to 21 mm). Results. A total of 439 patients underwent AVR (pledgeted, n = 212; nonpledgeted, n = 122; figure-of-eight, n = 105). The groups were similar in age (P = .359), sex (P = .055), underlying disease, and valve pathology. There was no difference in inhospital mortality or cardiac adverse events in each suture group (P = .282). The nonpledgeted suture had significantly lower moderate (P < .01) and severe PPM rates (P = .01) in patients with a small aortic annulus (18 to 21 mm). Conclusions. The interrupted nonpledget mattress suture offers complete supraannular implantation, which reduces the incidence of PPM and results in better hemodynamic improvement after small-size AVR. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:661 / 667
页数:7
相关论文
共 50 条
  • [41] Influence of prosthesis-patient mismatch on exercise-induced arrhythmias: A further aspect after aortic valve replacement
    Mannacio, Vito Antonio
    De Amicis, Vincenzo
    Di Tommaso, Luigi
    Iorio, Francesco
    Vosa, Carlo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (03): : 632 - 638
  • [42] Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Leone, Pier Pasquale
    Fazzari, Fabio
    Cannata, Francesco
    Sanz-Sanchez, Jorge
    Mangieri, Antonio
    Monti, Lorenzo
    Cozzi, Ottavia
    Stefanini, Giulio Giuseppe
    Bragato, Renato
    Colombo, Antonio
    Reimers, Bernhard
    Regazzoli, Damiano
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [43] Impact of prosthesis-patient mismatch on early and late outcomes after mitral valve replacement: a meta-analysis
    Tan, Meng-Wei
    Bai, Yi-Fan
    Liu, Xiao-Hong
    Xu, Zhi-Yun
    An, Zhao
    Ma, Ye
    Zhao, Li-Bo
    Li, Bai-Ling
    JOURNAL OF GERIATRIC CARDIOLOGY, 2020, 17 (08) : 455 - 475
  • [44] Prosthesis-patient mismatch following transcatheter aortic valve replacement for degenerated transcatheter aortic valves: the TRANSIT-PPM international project
    Testa, Luca
    Casenghi, Matteo
    Criscione, Enrico
    Van Mieghem, Nicolas M.
    Tchetche, Didier
    Asgar, Anita W.
    De Backer, Ole
    Latib, Azeem
    Reimers, Bernhard
    Stefanini, Giulio
    Trani, Carlo
    Giannini, Francesco
    Bartorelli, Antonio
    Wojakowski, Wojtek
    Dabrowski, Maciej
    Jagielak, Dariusz
    Banning, Adrian P.
    Kharbanda, Rajesh
    Moreno, Raul
    Schofer, Joachim
    Brinkmann, Christina
    van Royen, Niels
    Pinto, Duane
    Serra, Antoni
    Segev, Amit
    Giordano, Arturo
    Brambilla, Nedy
    Agnifili, Mauro
    Rubbio, Antonio Popolo
    Squillace, Mattia
    Oreglia, Jacopo
    Tanja, Rudolph
    McCabe, James M.
    Abizaid, Alexander
    Voskuil, Michiel
    Teles, Rui
    Zoccai, Giuseppe Biondi
    Sondergaard, Lars
    Bedogni, Francesco
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [45] Prosthesis-patient Mismatch after Mitral Valve Replacement Stratified by Referred and Measured Effective Valve Area
    Matsuura, Kaoru
    Mogi, Kenji
    Aoki, Chikashi
    Takahara, Yoshiharu
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 17 (02) : 153 - 159
  • [46] Incidence, Predictors, and Clinical Impact of Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement in Asian Patients The OCEAN-TAVI Registry
    Miyasaka, Masaki
    Tada, Norio
    Taguri, Masataka
    Kato, Shigeaki
    Enta, Yusuke
    Otomo, Tatsushi
    Hata, Masaki
    Watanabe, Yusuke
    Naganuma, Toru
    Araki, Motoharu
    Yamanaka, Futoshi
    Shirai, Shinichi
    Ueno, Hiroshi
    Mizutani, Kazuki
    Tabata, Minoru
    Higashimori, Akihiro
    Takagi, Kensuke
    Yamamoto, Masanori
    Hayashida, Kentaro
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (08) : 771 - 780
  • [47] Surgical versus transcatheter aortic valve replacement: Impact of patient-prosthesis mismatch on outcomes
    Alnajar, Ahmed
    Hamad, Naser
    Azhar, Muhammad Z.
    Mousa, Yaseen
    Arora, Yingyot
    Lamelas, Joseph
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 5388 - 5394
  • [48] Open transcatheter valve replacement for prosthesis-patient mismatch at redo surgical aortic valve replacement (Jul, 10.21037/acs-2021-tviv-58, 2021)
    Cekmecelioglu, Davut
    Chatterjee, Subhasis
    Coselli, Joseph S.
    Preventza, Ourania
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (05) : 711 - 713
  • [49] Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis
    Liao, Yan-biao
    Li, Yi-jian
    Li Jun-Li
    Zhao, Zhen-gang
    Wei, Xin
    Tsauo, Jiay-yu
    Xiong, Tian-yuan
    Xu, Yuan-ning
    Feng, Yuan
    Chen, Mao
    SCIENTIFIC REPORTS, 2017, 7
  • [50] Prosthesis-patient mismatch affects late survival after valve surgery for severe aortic stenosis
    Swinkels, Ben M.
    Ten Berg, Jurrien M.
    Kelder, Johannes C.
    Vermeulen, Freddy E.
    van Boven, Wim J.
    de Mol, Bas A.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2022, 63 (01): : 91 - 98