Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch

被引:19
|
作者
Kim, Hyo-Hyun [1 ]
Lee, Sak [1 ]
Joo, Hyun-Chel [1 ]
Kim, Jung-Hwan [1 ]
Youn, Young-Nam [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Seung-Hyun [1 ]
机构
[1] Yonsei Univ, Yonsei Univ Hlth Syst, Severance Cardiovasc Hosp, Div Cardiovasc Surg,Coll Med, 250 Seongsanno, Seoul 03722, South Korea
来源
ANNALS OF THORACIC SURGERY | 2020年 / 109卷 / 03期
关键词
HEMODYNAMIC PERFORMANCE; MORTALITY;
D O I
10.1016/j.athoracsur.2019.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Many variables may affect the hemodynamic performance of the aortic valve prosthesis, and suture technique remains an important factor for determining maximum valve performance. The objective of this study was to determine the suture technique that produces better hemodynamic performance for aortic valve replacement (AVR). Methods. Patients who underwent AVR between January 2015 and September 2018 in our institution were analyzed. We compared the preoperative clinical information and 1-year postoperative hemodynamic data of interrupted pledget mattress sutures (pledgeted group), interrupted nonpledget mattress sutures (nonpledgeted group), and figure-of-8 nonpledget sutures (figure-of-eight group). We compared the incidence of prosthesis-patient mismatch (PPM) and cardiac adverse events among the groups and subanalyzed the PPM rate in a small aortic annulus (18 to 21 mm). Results. A total of 439 patients underwent AVR (pledgeted, n = 212; nonpledgeted, n = 122; figure-of-eight, n = 105). The groups were similar in age (P = .359), sex (P = .055), underlying disease, and valve pathology. There was no difference in inhospital mortality or cardiac adverse events in each suture group (P = .282). The nonpledgeted suture had significantly lower moderate (P < .01) and severe PPM rates (P = .01) in patients with a small aortic annulus (18 to 21 mm). Conclusions. The interrupted nonpledget mattress suture offers complete supraannular implantation, which reduces the incidence of PPM and results in better hemodynamic improvement after small-size AVR. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:661 / 667
页数:7
相关论文
共 50 条
  • [31] Impact of Prosthesis-Patient Mismatch on Survival after Mitral Valve Replacement: A Meta-analysis
    Hwang, Ho-Young N.
    Sohn, Suk-Ho
    Jang, Myoung-jin
    THORACIC AND CARDIOVASCULAR SURGEON, 2019, 67 (07): : 538 - 545
  • [32] Prosthesis-patient mismatch is an independent predictor of congestive heart failure after transcatheter aortic valve replacement
    Theron, Alexis
    Lavagna, Flora
    Gaubert, Guillaume
    Resseguier, Noemie
    Porto, Alizee
    Ferrara, Jerome
    Jaussaud, Nicolas
    Morera, Pierre
    Cuisset, Thomas
    Deharo, Pierre
    Collart, Frederic
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2021, 114 (6-7) : 504 - 514
  • [33] Impact of Prosthesis-Patient Mismatch on Long-Term Survival After Aortic Valve Replacement Influence of Age, Obesity, and Left Ventricular Dysfunction
    Mohty, Dania
    Dumesnil, Jean G.
    Echahidi, Najmeddine
    Mathieu, Patrick
    Dagenais, Francois
    Voisine, Pierre
    Pibarot, Philippe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (01) : 39 - 47
  • [34] The Problem of Severe Valve Prosthesis-Patient Mismatch in Aortic Bioprostheses: Near Extinction?
    Dumesnil, Jean G.
    Pibarot, Philippe
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (06) : 598 - 600
  • [35] Prosthesis-patient mismatch following aortic and mitral valves replacement - A comprehensive review
    Joury, Abdulaziz
    Duran, Antonio
    Stewart, Merrill
    Gilliland, Yvonne E.
    Spindel, Stephen M.
    Qamruddin, Salima
    PROGRESS IN CARDIOVASCULAR DISEASES, 2022, 72 : 84 - 92
  • [36] Patient-prosthesis mismatch in patients with aortic valve replacement
    Kaminishi Y.
    Misawa Y.
    Kobayashi J.
    Konishi H.
    Miyata H.
    Motomura N.
    Takamoto S.-I.
    General Thoracic and Cardiovascular Surgery, 2013, 61 (5) : 274 - 279
  • [37] Effect of Prosthesis-Patient Mismatch on Long-Term Survival With Aortic Valve Replacement: Assessment to 15 Years
    Jamieson, W. R. Eric
    Ye, Jian
    Higgins, Jennifer
    Cheung, Anson
    Fradet, Guy J.
    Skarsgard, Peter
    Germann, Eva
    Chan, Florence
    Lichtenstein, Samuel V.
    ANNALS OF THORACIC SURGERY, 2010, 89 (01): : 51 - 59
  • [38] Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Prosthesis
    Van Linden, Arnaud
    Kempfert, Joerg
    Blumenstein, Johannes
    Rastan, Ardawan
    Holzhey, David
    Lehmann, Sven
    Mohr, Friedrich W.
    Walther, Thomas
    THORACIC AND CARDIOVASCULAR SURGEON, 2013, 61 (05): : 414 - 420
  • [39] Prosthesis-patient mismatch defined by cardiac computed tomography versus echocardiography after transcatheter aortic valve replacement
    Fukui, Miho
    Garcia, Santiago
    Lesser, John R.
    Gossl, Mario
    Tang, Liang
    Caye, David
    Newell, Marc
    Hashimoto, Go
    Lopes, Bernardo B. C.
    Stanberry, Larissa, I
    Enriquez-Sarano, Maurice
    Pibarot, Philippe
    Hahn, RebeccaT
    Sorajja, Paul
    Cavalcante, Joao L.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (05) : 403 - 411
  • [40] Relationship between Prosthesis-Patient Mismatch and Pro-Brain Natriuretic Peptides after Aortic Valve Replacement
    Melina, Giovanni
    Angeloni, Emiliano
    Benedetto, Umberto
    Refice, Simone
    Miele, Antonio
    Miele, Cristina
    Ciavarella, Giuseppino M.
    Sinatra, Riccardo
    JOURNAL OF HEART VALVE DISEASE, 2010, 19 (02): : 171 - 176