Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch

被引:19
|
作者
Kim, Hyo-Hyun [1 ]
Lee, Sak [1 ]
Joo, Hyun-Chel [1 ]
Kim, Jung-Hwan [1 ]
Youn, Young-Nam [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Seung-Hyun [1 ]
机构
[1] Yonsei Univ, Yonsei Univ Hlth Syst, Severance Cardiovasc Hosp, Div Cardiovasc Surg,Coll Med, 250 Seongsanno, Seoul 03722, South Korea
来源
ANNALS OF THORACIC SURGERY | 2020年 / 109卷 / 03期
关键词
HEMODYNAMIC PERFORMANCE; MORTALITY;
D O I
10.1016/j.athoracsur.2019.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Many variables may affect the hemodynamic performance of the aortic valve prosthesis, and suture technique remains an important factor for determining maximum valve performance. The objective of this study was to determine the suture technique that produces better hemodynamic performance for aortic valve replacement (AVR). Methods. Patients who underwent AVR between January 2015 and September 2018 in our institution were analyzed. We compared the preoperative clinical information and 1-year postoperative hemodynamic data of interrupted pledget mattress sutures (pledgeted group), interrupted nonpledget mattress sutures (nonpledgeted group), and figure-of-8 nonpledget sutures (figure-of-eight group). We compared the incidence of prosthesis-patient mismatch (PPM) and cardiac adverse events among the groups and subanalyzed the PPM rate in a small aortic annulus (18 to 21 mm). Results. A total of 439 patients underwent AVR (pledgeted, n = 212; nonpledgeted, n = 122; figure-of-eight, n = 105). The groups were similar in age (P = .359), sex (P = .055), underlying disease, and valve pathology. There was no difference in inhospital mortality or cardiac adverse events in each suture group (P = .282). The nonpledgeted suture had significantly lower moderate (P < .01) and severe PPM rates (P = .01) in patients with a small aortic annulus (18 to 21 mm). Conclusions. The interrupted nonpledget mattress suture offers complete supraannular implantation, which reduces the incidence of PPM and results in better hemodynamic improvement after small-size AVR. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:661 / 667
页数:7
相关论文
共 50 条
  • [21] Incidence and impact of prosthesis-patient mismatch following transcatheter aortic valve implantation
    Seoudy, Hatim
    Guessefeld, Nathalie
    Frank, Johanne
    Freitag-Wolf, Sandra
    Lutter, Georg
    Eden, Matthias
    Rangrez, AshrafYusuf
    Kuhn, Christian
    Frey, Norbert
    Frank, Derk
    CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (06) : 660 - 668
  • [22] Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?
    Lee, Seung Hyun
    Chang, Byung Chul
    Youn, Young-Nam
    Joo, Hyun Chel
    Yoo, Kyung-Jong
    Lee, Sak
    JOURNAL OF CARDIOTHORACIC SURGERY, 2017, 12
  • [23] Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?
    Seung Hyun Lee
    Byung Chul Chang
    Young-Nam Youn
    Hyun Chel Joo
    Kyung-Jong Yoo
    Sak Lee
    Journal of Cardiothoracic Surgery, 12
  • [24] Impact of prosthesis-iteration evolution and sizing practice on the incidence of prosthesis-patient mismatch after transcatheter aortic valve replacement
    Abdelghani, Mohammad
    Allali, Abdelhakim
    Kaur, Jatinderjit
    Hemetsberger, Rayyan
    Mehilli, Julinda
    Neumann, Franz-Josef
    Frerker, Christian
    Kurz, Thomas
    El-Mawardy, Mohamed
    Richardt, Gert
    Abdel-Wahab, Mohamed
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (05) : 971 - 979
  • [25] Impact of Prosthesis-Patient Mismatch on Long-term Functional Capacity After Mechanical Aortic Valve Replacement
    Petit-Eisenmann, Helene
    Epailly, Eric
    Velten, Michel
    Radojevic, Jelena
    Eisenmann, Bernard
    Kremer, Helene
    Kindo, Michel
    CANADIAN JOURNAL OF CARDIOLOGY, 2016, 32 (12) : 1493 - 1499
  • [26] Prosthesis-patient mismatch after transcatheter aortic valve implantation
    Leone, Pier Pasquale
    Pagnesi, Matteo
    Regazzoli, Damiano
    Latib, Azeem
    GIORNALE ITALIANO DI CARDIOLOGIA, 2020, 21 (11) : 26S - 34S
  • [27] Impact of prosthesis-patient mismatch on survival after mitral valve replacement: a systematic review
    Zhang Jian-feng
    Wu Yi-cheng
    Shen Wei-feng
    Kong Ye
    CHINESE MEDICAL JOURNAL, 2013, 126 (19) : 3762 - 3766
  • [28] Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Muratori, Manuela
    Delgado, Victoria
    Pepi, Mauro
    Tamborini, Gloria
    Fusini, Laura
    Klautz, Robert J. M.
    Gripari, Paola
    Bax, Jeroen J.
    Fusari, Melissa
    Schalij, Martin J.
    Marsan, Nina Ajmone
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1910 - 1918
  • [29] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement It Is Neither Rare Nor Benign
    Pibarot, Philippe
    Clavel, Marie-Annick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) : 2712 - 2716
  • [30] Prosthesis-Patient Mismatch Increases Early and Late Mortality in Low Risk Aortic Valve Replacement
    Elmahdy, Walid
    Osman, Mohamed
    Farag, Mohamed
    Shoaib, Ahmad
    Saad, Haisam
    Sullivan, Keith
    Krishnan, Unni
    Nashef, Samer
    Berman, Marius
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2021, 33 (01) : 23 - 30