Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch

被引:19
作者
Kim, Hyo-Hyun [1 ]
Lee, Sak [1 ]
Joo, Hyun-Chel [1 ]
Kim, Jung-Hwan [1 ]
Youn, Young-Nam [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Seung-Hyun [1 ]
机构
[1] Yonsei Univ, Yonsei Univ Hlth Syst, Severance Cardiovasc Hosp, Div Cardiovasc Surg,Coll Med, 250 Seongsanno, Seoul 03722, South Korea
关键词
HEMODYNAMIC PERFORMANCE; MORTALITY;
D O I
10.1016/j.athoracsur.2019.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Many variables may affect the hemodynamic performance of the aortic valve prosthesis, and suture technique remains an important factor for determining maximum valve performance. The objective of this study was to determine the suture technique that produces better hemodynamic performance for aortic valve replacement (AVR). Methods. Patients who underwent AVR between January 2015 and September 2018 in our institution were analyzed. We compared the preoperative clinical information and 1-year postoperative hemodynamic data of interrupted pledget mattress sutures (pledgeted group), interrupted nonpledget mattress sutures (nonpledgeted group), and figure-of-8 nonpledget sutures (figure-of-eight group). We compared the incidence of prosthesis-patient mismatch (PPM) and cardiac adverse events among the groups and subanalyzed the PPM rate in a small aortic annulus (18 to 21 mm). Results. A total of 439 patients underwent AVR (pledgeted, n = 212; nonpledgeted, n = 122; figure-of-eight, n = 105). The groups were similar in age (P = .359), sex (P = .055), underlying disease, and valve pathology. There was no difference in inhospital mortality or cardiac adverse events in each suture group (P = .282). The nonpledgeted suture had significantly lower moderate (P < .01) and severe PPM rates (P = .01) in patients with a small aortic annulus (18 to 21 mm). Conclusions. The interrupted nonpledget mattress suture offers complete supraannular implantation, which reduces the incidence of PPM and results in better hemodynamic improvement after small-size AVR. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:661 / 667
页数:7
相关论文
共 15 条
[1]  
Aoyagi Shigeaki, 2007, Nihon Geka Gakkai Zasshi, V108, P59
[2]   Prosthesis size and long-term survival after aortic valve replacement [J].
Blackstone, EH ;
Cosgrove, DM ;
Jamieson, WRE ;
Birkmeyer, NJ ;
Lemmer, JH ;
Miller, DC ;
Butchart, EG ;
Rizzoli, G ;
Yacoub, M ;
Chai, AK .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) :783-796
[3]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[4]   Importance of implant technique on risk of major paravatvutar teak (PVL) after St. Jude mechanical heart valve replacement: a report from the Artificial Valve Endocarditis Reduction Trial (AVERT) [J].
Englberger, L ;
Schaff, HV ;
Jamieson, WRE ;
Kennard, ED ;
Im, KA ;
Holubkov, R ;
Carrel, TP .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (06) :838-843
[5]   The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement [J].
Fallon, John M. ;
DeSimone, Joseph P. ;
Brennan, J. Matthew ;
O'Brien, Sean ;
Thibault, Dylan P. ;
DiScipio, Anthony W. ;
Pibarot, Philippe ;
Jacobs, Jeffrey P. ;
Malenka, David J. ;
Clarizia, Nadia A. ;
Ruel, Marc .
ANNALS OF THORACIC SURGERY, 2018, 106 (01) :14-23
[6]   Multicentre, propensity-matched study to evaluate long-term impact of implantation technique in isolated aortic valve replacement on mortality and incidence of redo surgery [J].
Haqzad, Yama ;
Loubani, Mahmoud ;
Chaudhry, Mubarak ;
Ariyaratnam, Priyadharshanan ;
Briffa, Norman .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (05) :599-605
[7]   Use of a nonpledgeted suture technique is safe and efficient for aortic valve replacement [J].
LaPar, Damien J. ;
Ailawadi, Gorav ;
Bhamidipati, Castigliano M. ;
Singh, Mansher ;
Dare, David ;
Kern, John A. ;
Kron, Irving L. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (02) :388-393
[8]  
Pibarot P, 1996, CAN J CARDIOL, V12, P379
[9]   Prosthesis-patient mismatch: definition, clinical impact, and prevention [J].
Pibarot, P. ;
Dumesnil, J. G. .
HEART, 2006, 92 (08) :1022-1029
[10]   Simple interrupted suturing increases valve performance after aortic valve replacement with a small supra-annular bioprosthesis [J].
Tabata, Minoru ;
Shibayama, Kentaro ;
Watanabe, Hiroyuki ;
Sato, Yasunori ;
Fukui, Toshihiro ;
Takanashi, Shuichiro .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (01) :321-325