Juvenile and adult congenital heart disease: Time-resolved 3D contrast-enhanced MR angiography

被引:31
作者
Fenchel, Michael
Saleh, Roya
Dinh, Howard
Lee, Margaret H.
Nael, Kambiz
Krishnam, Mayil
Ruehm, Stefan G.
Miller, Stephan
Child, John
Finn, J. Paul
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA USA
关键词
D O I
10.1148/radiol.2442061045
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the incremental diagnostic value of time-resolved three-dimensional (3D) magnetic resonance (MR) angiography over single-phase 3D MR angiography and cine MR imaging in juvenile and adult patients with congenital heart disease (CHD). Materials and Methods: The study was HIPAA compliant and was approved by the institutional review board. Written informed consent was obtained from each patient. Eighty-one consecutive patients (46 male and 35 female patients; mean age, 31.1 years +/- 13.5 [standard deviation]) with CHD were examined with a 1.5-T MR imaging unit. The imaging protocol comprised time- resolved MR angiography (repetition time msec/echo time msec, 2.01/ 0.81) after injection of 0.03 mmol gadodiamide per kilogram of body weight at 4 mL/ sec and single-phase high-spatial-resolution MR angiography (2.87/ 0.97) after injection of 0.15 mmol/ kg gadodiamide at 1.5 mL/ sec. After review of the time-resolved and conventional MR angiographic data sets, each of two independent observers listed the additional clinical information gained from timeresolved MR angiographic data. A Wilcoxon signed rank test was used to test for statistical differences between the image quality ratings of the two observers. Results: Time-resolved and single-phase high-spatial-resolution MR angiography yielded diagnostic image data in all patients. Observers 1 and 2 found functional information in time-resolved MR angiographic series in 52 and 51 patients, respectively, that was not seen at high-spatial-resolution MR angiography. Intra- and extracardiac shunts, respectively, were exclusively depicted by time-resolved MR angiography for observer 1 in 18 and two patients and for observer 2 in 15 and two patients. However, both observers reported higher confidence in the assessment of such smaller vascular structures as supraaortic vessels ( in 12 patients for observer 1 and 11 patients for observer 2) and major aortopulmonary collateral arteries (in eight patients for observer 1 and 10 patients for observer 2) at high-spatial-resolution MR angiography. No significant difference was evident in image quality scoring between the two observers (P =.32 for time- resolved and P =.47 for conventional MR angiography). Conclusion: Compared with conventional MR angiography, time-resolved MR angiography yields clinically relevant information in a substantial number of patients; hence, the two techniques should be regarded as complementary.
引用
收藏
页码:399 / 410
页数:12
相关论文
共 32 条
[1]  
[Anonymous], 2005, HEART DIS STROKE STA
[2]   Gadolinium-enhanced 3D MR angiography of renal artery stenosis: A pilot comparison of maximum intensity projection, multiplanar reformatting, and 3D volume-rendering postprocessing algorithms [J].
Baskaran, V ;
Pereles, FS ;
Nemcek, AA ;
Carr, JC ;
Miller, FH ;
Ly, J ;
Krupinski, E ;
Finn, JP .
ACADEMIC RADIOLOGY, 2002, 9 (01) :50-59
[3]   10-YEARS EXPERIENCE WITH THE SENNING OPERATION FOR TRANSPOSITION OF THE GREAT-ARTERIES - PHYSIOLOGICAL RESULTS AND LATE FOLLOW-UP [J].
BENDER, HW ;
STEWART, JR ;
MERRILL, WH ;
HAMMON, JW ;
GRAHAM, TP .
ANNALS OF THORACIC SURGERY, 1989, 47 (02) :218-223
[4]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[5]   Magnetic resonance angiography of the body in pediatric patients: experience with a contrast-enhanced time-resolved technique [J].
Chung, T .
PEDIATRIC RADIOLOGY, 2005, 35 (01) :3-10
[6]   Detection and quantification of valvular heart disease with dynamic cardiac MR imaging [J].
Didier, D ;
Ratib, O ;
Lerch, R ;
Friedli, B .
RADIOGRAPHICS, 2000, 20 (05) :1279-1299
[7]  
DOWDLE SC, 1990, J NUCL MED, V31, P1276
[8]   AORTIC-VALVE PRESSURE-GRADIENTS IN PATIENTS WITH AORTIC-VALVE STENOSIS - QUANTIFICATION WITH VELOCITY-ENCODED CINE MR IMAGING [J].
EICHENBERGER, AC ;
JENNI, R ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :971-977
[9]   Partially parallel three-dimensional magnetic resonance imaging for the assessment of lung perfusion -: Initial results [J].
Fink, C ;
Bock, M ;
Puderbach, M ;
Schmähl, A ;
Delorme, S .
INVESTIGATIVE RADIOLOGY, 2003, 38 (08) :482-488
[10]  
Fink C, 2005, INVEST RADIOL, V40, P40