Inverter nonlinearity effects in high frequency signal injection-based, sensorless control methods

被引:0
作者
Guerrero, JM [1 ]
Leetmaa, M [1 ]
Briz, F [1 ]
Zamarrón, A [1 ]
Lorenz, RD [1 ]
机构
[1] Univ Oviedo, Dept Elect & Comp Syst Engn, Gijon 33204, Spain
来源
2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS | 2003年
关键词
dead-time; PWM; saliency; sensorless;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An analysis of PWM inverter nonlinearities influencing high frequency carrier signal voltage injection for saliency-tracking-based rotor/flux position estimation is presented in this paper. Distortion of the injected carrier voltage caused by the nonlinear behavior of the inverter has been reported to cause errors in the estimated rotor/flux position. Though a number of techniques have been developed to compensate for inverter nonlinearities, they have not been proven to be effective when a high frequency, low magnitude voltage needs to be generated. Both the origins of the distortion as well as the requirements for compensation methods to be effective when producing such high frequency voltages will be established in this paper.
引用
收藏
页码:1157 / 1164
页数:8
相关论文
共 29 条