Quantification of Coronary Artery Calcium on the Basis of Dual-Energy Coronary CT Angiography

被引:64
作者
Schwarz, Florian [1 ,2 ]
Nance, John W., Jr. [1 ,3 ]
Ruzsics, Balazs [1 ,4 ]
Bastarrika, Gorka [1 ,5 ]
Sterzik, Alexander [1 ,2 ]
Schoepf, U. Joseph [1 ,2 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29401 USA
[2] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[3] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[4] Royal Liverpool & Broadgreen Univ Hosp, Dept Cardiol, Liverpool, Merseyside, England
[5] Univ Navarra, Dept Radiol, E-31080 Pamplona, Spain
关键词
BEAM COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; PROGNOSTIC VALUE; ASYMPTOMATIC INDIVIDUALS; IMAGE-RECONSTRUCTION; SYMPTOMATIC PATIENTS; RISK-FACTORS; DISEASE; HEART; PERFORMANCE;
D O I
10.1148/radiol.12112455
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of using virtual noncontrast material-enhanced (VNC) computed tomographic (CT) series derived from dual-energy CT imaging studies for coronary artery calcium quantification. Materials and Methods: This HIPAA-compliant study was institutional review board approved; all patients provided written informed consent. Thirty-six patients prospectively underwent noncontrast-enhanced CT calcium scoring followed by coronary CT angiography performed in dual-energy mode. By using different reconstruction algorithms, three VNC series were generated and evaluated for noise and efficiency of virtual iodine removal. Two readers independently quantified calcium on VNC images and true noncontrast-enhanced conventional calcium scoring series. A leave-one-out cross validation was used to assess the accuracy of calcium score prediction from VNC series by means of linear regression. Results: CT value histograms of the VNC series closely resembled the profile in the true noncontrast-enhanced series. There was excellent correlation between calcium volumes on the VNC series and true noncontrast-enhanced series on a per-patient (r = 0.94, P < .001, n = 36) and per-vessel (r = 0.94, 0.91, and 0.92 for the three coronary arteries, all P < .001, n = 36 each) level. The ability of a linear regression model to predict actual calcium scores from calcium volumes on VNC series was excellent (r = 0.82). Multiethnic Study of Atherosclerosis rankings that were derived from the predicted calcium scores also showed excellent agreement (intraclass correlation coefficient = 0.909). Conclusion: Coronary artery calcium identification and quantification based on dual-energy coronary CT angiographic studies may obviate the need for dedicated CT calcium scoring studies. (C) RSNA, 2012
引用
收藏
页码:700 / 707
页数:8
相关论文
共 27 条
[21]   High-Temporal Resolution Dual-Energy Computed Tomography of the Heart Using a Novel Hybrid Image Reconstruction Algorithm: Initial Experience [J].
Nance, John William, Jr. ;
Bastarrika, Gorka ;
Kang, Doo Kyoung ;
Ruzsics, Balazs ;
Vogt, Sebastian ;
Schmidt, Bernhard ;
Raupach, Rainer ;
Flohr, Thomas G. ;
Schoepf, U. Joseph .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (01) :119-125
[22]   Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience [J].
Ruzsics, Balazs ;
Lee, Heon ;
Zwerner, Peter L. ;
Gebregziabher, Mulugeta ;
Costello, Philip ;
Schoepf, U. Joseph .
EUROPEAN RADIOLOGY, 2008, 18 (11) :2414-2424
[23]   Comparison of Dual-Energy Computed Tomography of the Heart With Single Photon Emission Computed Tomography for Assessment of Coronary Artery Stenosis and of the Myocardial Blood Supply [J].
Ruzsics, Balazs ;
Schwarz, Florian ;
Schoepf, U. Joseph ;
Lee, Yeong Shyan ;
Bastarrika, Gorka ;
Chiaramida, Salvatore A. ;
Costello, Philip ;
Zwerner, Peter L. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (03) :318-326
[24]   Prognostic value of electron-beam computed tomography-derived coronary calcium scores compared with clinical parameters in patients evaluated for coronary artery disease -: Prognostic value of EBCT in symptomatic patients [J].
Schmermund, A ;
Stang, A ;
Möhlenkamp, S ;
Eggebrecht, H ;
Baumgart, D ;
Gilbert, V ;
Grönemeyer, D ;
Seibel, R ;
Erbel, R .
ZEITSCHRIFT FUR KARDIOLOGIE, 2004, 93 (09) :696-705
[25]   Prognostic value of cardiac risk factors and coronary artery calcium screening for all-cause mortality [J].
Shaw, LJ ;
Raggi, P ;
Schisterman, E ;
Berman, DS ;
Callister, TQ .
RADIOLOGY, 2003, 228 (03) :826-833
[26]   Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT [J].
Stolzmann, Paul ;
Frauenfelder, Thomas ;
Pfammatter, Thomas ;
Peter, Nicole ;
Scheffel, Hans ;
Lachat, Mario ;
Schmidt, Bernhard ;
Marincek, Borut ;
Alkadhi, Hatem ;
Schertler, Thomas .
RADIOLOGY, 2008, 249 (02) :682-691
[27]   Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: Meta-analysis [J].
Vanhoenacker, Piet K. ;
Heijenbrok-Kal, Majanka H. ;
Van Heste, Ruben ;
Decramer, Isabel ;
Van Hoe, Lieven R. ;
William, Wijns ;
Hunink, M. G. Myriam .
RADIOLOGY, 2007, 244 (02) :419-428