Quantification of Coronary Artery Calcium on the Basis of Dual-Energy Coronary CT Angiography

被引:61
|
作者
Schwarz, Florian [1 ,2 ]
Nance, John W., Jr. [1 ,3 ]
Ruzsics, Balazs [1 ,4 ]
Bastarrika, Gorka [1 ,5 ]
Sterzik, Alexander [1 ,2 ]
Schoepf, U. Joseph [1 ,2 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29401 USA
[2] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[3] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[4] Royal Liverpool & Broadgreen Univ Hosp, Dept Cardiol, Liverpool, Merseyside, England
[5] Univ Navarra, Dept Radiol, E-31080 Pamplona, Spain
关键词
BEAM COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; PROGNOSTIC VALUE; ASYMPTOMATIC INDIVIDUALS; IMAGE-RECONSTRUCTION; SYMPTOMATIC PATIENTS; RISK-FACTORS; DISEASE; HEART; PERFORMANCE;
D O I
10.1148/radiol.12112455
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of using virtual noncontrast material-enhanced (VNC) computed tomographic (CT) series derived from dual-energy CT imaging studies for coronary artery calcium quantification. Materials and Methods: This HIPAA-compliant study was institutional review board approved; all patients provided written informed consent. Thirty-six patients prospectively underwent noncontrast-enhanced CT calcium scoring followed by coronary CT angiography performed in dual-energy mode. By using different reconstruction algorithms, three VNC series were generated and evaluated for noise and efficiency of virtual iodine removal. Two readers independently quantified calcium on VNC images and true noncontrast-enhanced conventional calcium scoring series. A leave-one-out cross validation was used to assess the accuracy of calcium score prediction from VNC series by means of linear regression. Results: CT value histograms of the VNC series closely resembled the profile in the true noncontrast-enhanced series. There was excellent correlation between calcium volumes on the VNC series and true noncontrast-enhanced series on a per-patient (r = 0.94, P < .001, n = 36) and per-vessel (r = 0.94, 0.91, and 0.92 for the three coronary arteries, all P < .001, n = 36 each) level. The ability of a linear regression model to predict actual calcium scores from calcium volumes on VNC series was excellent (r = 0.82). Multiethnic Study of Atherosclerosis rankings that were derived from the predicted calcium scores also showed excellent agreement (intraclass correlation coefficient = 0.909). Conclusion: Coronary artery calcium identification and quantification based on dual-energy coronary CT angiographic studies may obviate the need for dedicated CT calcium scoring studies. (C) RSNA, 2012
引用
收藏
页码:700 / 707
页数:8
相关论文
共 50 条
  • [1] Dual-Energy Material Decomposition for Coronary Artery Calcium Quantification
    Black, D.
    Molloi, S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7834 - 7834
  • [2] A novel method of coronary artery calcium quantification on CT coronary angiography
    Pavitt, C. W.
    Lindsay, A. C.
    Zielke, S.
    Ray, R.
    Harron, K.
    Padley, S.
    Rubens, M.
    Nicol, E.
    EUROPEAN HEART JOURNAL, 2013, 34 : 521 - 521
  • [3] Dual-energy Computed Tomography in Coronary Artery Calcium Scoring
    Abhijith, S.
    Jaseemudheen, M. M.
    HEART VIEWS, 2024, 25 (02): : 74 - 79
  • [4] Impact of monochromatic coronary computed tomography angiography from single-source dual-energy CT on coronary stenosis quantification
    Stehli, Julia
    Clerc, Olivier F.
    Fuchs, Tobias A.
    Possner, Mathias
    Graeni, Christoph
    Benz, Dominik C.
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (02) : 135 - 140
  • [5] Dual-energy CT and coronary imaging
    Kay, Fernando Uliana
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (04) : 1090 - 1107
  • [6] Quantification of volumetric coronary blood flow with dual-energy digital subtraction angiography
    Molloi, S
    Ersahin, A
    Tang, J
    Hicks, J
    Leung, CY
    CIRCULATION, 1996, 93 (10) : 1919 - 1927
  • [7] QUANTIFICATION OF THE ABSOLUTE VOLUMETRIC CORONARY FLOW WITH DUAL-ENERGY DIGITAL SUBTRACTION ANGIOGRAPHY
    MOLLOI, S
    ERSAHIN, A
    QIAN, YJ
    HICKS, JW
    WALLIS, JB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A91 - A91
  • [8] Synthesizing High-Resolution Dual-Energy Radiographs from Coronary Artery Calcium CT Images
    Shaker, Kian
    Shi, Linxi
    Hsieh, Scott
    Swaby, Akyl
    Abbaszadeh, Shiva
    Wang, Adam S.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [9] COMBINATION OF CORONARY ARTERY CALCIUM AND CORONARY CT ANGIOGRAPHY FOR THE DIAGNOSIS OF OBSTRUCTIVE CORONARY ARTERY DISEASE
    Messenger, Bradley S.
    Hamirani, Yasmin
    Zeb, Irfan
    Budoff, Matthew J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [10] Application of coronary artery calcium score measurement on coronary CT angiography
    Zhang, Zhang
    Guo, Jingjing
    Deng, Yuanlin
    Yan, Yan
    Yang, Fan
    Li, Tongli
    Jia, Bingzhen
    Zhang, Ningnannan
    Li, Dong
    CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2022, 5 (02) : 132 - 140