Comparative fire behavior of reinforced RPC and NSC simply supported beams

被引:48
作者
Hou, Xiaomeng [1 ,2 ]
Ren, Pengfei [1 ,2 ]
Rong, Qin [3 ]
Zheng, Wenzhong [1 ,2 ]
Zhan, Yao [1 ,2 ]
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Minist Ind & Informat Technol, Harbin 150090, Heilongjiang, Peoples R China
[3] Harbin Univ Sci & Technol, Sch Architecture & Civil Engn, Harbin 150080, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Reactive powder concrete (RPC); Simply supported beams; Fire resistance performance; Failure mode; Fire-induced spalling; Fiber content; REACTIVE POWDER CONCRETE; HIGH-TEMPERATURE; PERFORMANCE; RESISTANCE; FIBER; DESIGN;
D O I
10.1016/j.engstruct.2019.01.097
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The behavior of reactive powder concrete (RPC) at high temperatures has been mainly studied at the material level, and relatively few experimental studies have been conducted on the fire performance of RPC beams. An experimental investigation was therefore undertaken to explore the behavior of four reinforced RPC simply supported beams exposed to fire on three sides. The results such as cross-section temperatures at different heights, mid-span deflections, axial thermal expansion, crack patterns, failure modes, and fire resistance of beams are presented in this paper. The data obtained from the tests were also used to evaluate the effects of significant parameters such as RPC cover thickness, load level and fiber content, on the thermal and structural response of RPC beams. The results show that during fire, RPC beams that are under-reinforced at room temperature may fail as the lightly reinforced beams. Both RPC cover thickness and load level significantly affect the fire behavior of reinforced RPC simply supported beams. The addition of 2% steel fibers and 0.2% polypropylene fibers is an effective method to prevent the fire induced spalling of the reinforced RPC beams. Furthermore, based on the experimental studies on RPC beams and the numerical studies on RPC beams and normal strength concrete (NSC) beams, the difference in the fire resistance performance between RPC beams and NSC beams was investigated. It is shown that under the same flexural capacity at room temperature, the NSC beams exhibit a better fire resistance performance than the RPC beams.
引用
收藏
页码:122 / 140
页数:19
相关论文
共 66 条
[1]   High temperature and residual properties of reactive powder concrete - A review [J].
Abid, Muhammad ;
Hou, Xiaomeng ;
Zheng, Wenzhong ;
Hussain, Raja Rizwan .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 147 :339-351
[2]  
[Anonymous], NISTIR6890
[3]  
[Anonymous], EXP STUD
[4]  
[Anonymous], INT J SOLIDS STRUCT
[5]  
[Anonymous], 199212 BSEN
[6]  
[Anonymous], ENG FRACT MECH
[7]  
[Anonymous], ULTR PERF FIBR REINF
[8]  
[Anonymous], 2012, THESIS
[9]  
[Anonymous], 2013, THESIS
[10]  
[Anonymous], BUILD STRUCT