Chaotic dynamics in circulation with Tohoku University vibrating flow pump

被引:1
|
作者
Nitta, S
Yambe, T
Kobayashi, SI
Hashimoto, H
Yoshizawa, M
Mastuki, H
Tabayashi, K
Takeda, H
机构
[1] Tohoku Univ, Inst Dev Aging & Canc, Dept Med Engn & Cardiol, Aoba Ku, Sendai, Miyagi 98077, Japan
[2] Tohoku Univ, Grad Sch Engn, Sendai, Miyagi 98077, Japan
[3] Ebara Corp, Sendai, Miyagi 98077, Japan
[4] Tohoku Univ, Sch Med, Dept Thorac & Cardiovasc Surg, Sendai, Miyagi 98077, Japan
[5] Tohoku Gakuin Univ, Fac Engn, Sendai, Miyagi 980, Japan
关键词
ventricular assist system; vibrating flow pump; fractal; chaos; box counting;
D O I
10.1046/j.1525-1594.1999.06288.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relative high frequency (10-50 Hz) for a totally implantable system. In this study, the effects of left ventricular assistance with this unique oscillated blood flow were analyzed by the use of nonlinear mathematics for evaluation as the whole circulatory regulatory system, not as the decomposed parts of the system. Left heart bypasses using the VFP from the left atrium to the descending aorta were performed in chronic animal experiments using healthy adult goats. The ECG, arterial blood pressure, VFP pump flow, and the flow of the descending aorta were recorded in the data recorder during awake conditions and analyzed in a personal computer system through an A-D convertor. By the use of nonlinear mathematics, time series data were embedded into the phase space, the Lyapunov numerical method, fractal dimension analysis, and power spectrum analysis were performed to evaluate nonlinear dynamics. During left ventricular assistance with the VFP, Mayer wave fluctuations were decreased in the power spectrum, the fractal dimension of the hemodynamics was significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that nonlinear dynamics, which mediate the cardiovascular dynamics, may be affected during left ventricular (LV) bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. Decreased sympathetic discharges may be the origin of the decreased Mayer wave and fractal dimension. These nonlinear dynamic analyses may be useful to design optimal VAS control.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 50 条
  • [21] Metabolic network dynamics in open chaotic flow
    Károlyi, G
    Scheuring, I
    Czárán, T
    CHAOS, 2002, 12 (02) : 460 - 469
  • [22] Recent progress on the vibrating flow pump as a totally implantable ventricular assist device
    Yambe, T
    Kobayashi, S
    Yoshizawa, T
    Tanaka, T
    Matsuki, T
    Sato, F
    Tabayashi, K
    Nitta, S
    ARTIFICIAL ORGANS, 2001, 25 (09) : 688 - 691
  • [23] Unique flow-control scheme for tidal flow circulation with the metaplus pump
    Laberteaux, K.R.
    Merz, S.I.
    ASAIO Journal, 2000, 46 (02)
  • [24] Mechanical axial flow blood pump to support cavopulmonary circulation
    Throckmorton, A. L.
    Kapadia, J.
    Madduri, D.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (11): : 970 - 982
  • [25] A Novel Valveless Pulsatile Flow Pump for Extracorporeal Blood Circulation
    Anatol, Joaquin
    Vignali, Emanuele
    Gasparotti, Emanuele
    Castro-Ruiz, Francisco
    Rubio, Manuel
    Barrios-Collado, Cesar
    Sierra-Pallares, Jose
    Celi, Simona
    ANNALS OF BIOMEDICAL ENGINEERING, 2025, : 966 - 979
  • [26] The dynamics of a rigid body in potential flow with circulation
    J. Vankerschaver
    E. Kanso
    J. E. Marsden
    Regular and Chaotic Dynamics, 2010, 15 : 606 - 629
  • [27] The Dynamics of a Rigid Body in Potential Flow with Circulation
    Vankerschaver, J.
    Kanso, E.
    Marsden, J. E.
    REGULAR & CHAOTIC DYNAMICS, 2010, 15 (4-5): : 606 - 629
  • [28] Computational fluid dynamics analysis of the pump parameters in the helical flow pump
    Hosoda, Kyohei
    Ishii, Kohei
    Isoyama, Takashi
    Saito, Itsuro
    Inoue, Yusuke
    Ariyoshi, Kouki
    Ono, Toshiya
    Nakagawa, Hidemoto
    Imachi, Kou
    Kumagai, Hiroshi
    Abe, Yusuke
    JOURNAL OF ARTIFICIAL ORGANS, 2014, 17 (01) : 9 - 15
  • [29] Computational fluid dynamics analysis of the pump parameters in the helical flow pump
    Kyohei Hosoda
    Kohei Ishii
    Takashi Isoyama
    Itsuro Saito
    Yusuke Inoue
    Kouki Ariyoshi
    Toshiya Ono
    Hidemoto Nakagawa
    Kou Imachi
    Hiroshi Kumagai
    Yusuke Abe
    Journal of Artificial Organs, 2014, 17 : 9 - 15
  • [30] Systematical experiment for optimal design of vibrating flow pump with jelly-fish valve
    Satoyuki Kawano
    Saki Miyagawa
    Atsushi Shirai
    Journal of Bionic Engineering, 2016, 13 : 166 - 179