Screening of microplastics in water and sludge lines of a drinking water treatment plant in Catalonia, Spain

被引:33
|
作者
Dronjak, Lara [1 ]
Exposito, Nora [1 ]
Rovira, Joaquim [1 ,2 ]
Florencio, Karin [4 ]
Emiliano, Pere [5 ]
Corzo, Beatriz [4 ]
Schuhmacher, Marta [1 ]
Valero, Fernando [5 ]
Sierra, Jordi [3 ]
机构
[1] Univ Rovira & Virgili, Dept Chem Engn, Environm Engn Lab, Paisos Catalans Ave 26, Tarragona 43007, Catalonia, Spain
[2] Univ Rovira & Virgili, IISPV, Sch Med, Lab Toxicol & Environm Hlth, St Llorenc 21, Reus 43201, Catalonia, Spain
[3] Univ Barcelona, Fac Pharm, Joan XXIII Ave S-N, Barcelona 08028, Catalonia, Spain
[4] Sorigue Grp, Ronda Guinardo 99, Barcelona 08041, Catalonia, Spain
[5] Ens Abastament Aigua Ter Llobregat ATL, St Marti Erm 30, Sant Joan Despi 08970, Barcelona, Spain
关键词
Plastic pollution; Drinking water; Sludge; Removal ratios; WASTE-WATER; MONITORING MICROPLASTICS; HUMAN HEALTH; IDENTIFICATION; REMOVAL; FIBERS; COAGULATION; PARTICLES; EXPOSURE; THREAT;
D O I
10.1016/j.watres.2022.119185
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microplastics (MPs) are emerging pollutants detected everywhere in the environment, with the potential to harm living organisms. The present study investigated the concentration, morphology, and composition of MPs, between 20 mu m and 5 mm, in a drinking water treatment plant (DWTP) located close to Barcelona (Catalonia, NE Spain). The sampling included different units of the DWTP, from influent to effluent as well as sludge line. Sampling strategy, filtration, allows sampling of large volumes of water avoiding sample contamination, and during 8 h in order to increase the representativeness of MPs collected. The pre-treatment of the samples consisted of advanced oxidation with Fenton's reagent and hydrogen peroxide, followed by density separation of the particles with zinc chloride solution. Visual identification was performed with an optical and stereoscopic microscope with final Fourier-transform infrared spectroscopic (FTIR) confirmation. MPs were found in all DWTP samples, with concentrations from 4.23 +/- 1.26 MPs/L to 0.075 +/- 0.019 MPs/L in the influent and effluent of the plant, respectively. The overall removal efficiency of the plant was 98.3%. The most dominant morphology was fibers followed by fragments and films. Twenty-two different polymer types were identified and synthetic cellulose, polyester, polyamide, polypropylene, polyethylene, polyurethane, and polyacrylonitrile were the most common. Although MPs could be incorporated from the distribution network, MPs intake from drinking water from this DWTP was not an important route compared to fish and seafood ingestion.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Possible Uses for Sludge from Drinking Water Treatment Plants
    Hidalgo, A. M.
    Murcia, M. D.
    Gomez, M.
    Gomez, E.
    Garcia-Izquierdo, C.
    Solano, C.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2017, 143 (03)
  • [32] Evidence-Based Framework to Manage Cyanobacteria and Cyanotoxins in Water and Sludge from Drinking Water Treatment Plants
    Jalili, Farhad
    Moradinejad, Saber
    Zamyadi, Arash
    Dorner, Sarah
    Sauve, Sebastien
    Prevost, Michele
    TOXINS, 2022, 14 (06)
  • [33] Possible Factors Influencing the Accumulation of Different Radionuclides in Sludge from a Drinking Water Treatment Plant Located in Southern Catalonia Between 2002 and 2018
    A. Peñalver
    T. Baciu
    F. Borrull
    C. Aguilar
    Water, Air, & Soil Pollution, 2020, 231
  • [34] Dewaterability of Digested Sludge Conditioned with Sludge from a Water Treatment Plant
    Kowalczyk, Mariusz
    Kamizela, Tomasz
    ROCZNIK OCHRONA SRODOWISKA, 2019, 21 (01): : 217 - 233
  • [35] Microplastics in drinking water? Present state of knowledge and open questions
    Ossmann, Barbara E.
    CURRENT OPINION IN FOOD SCIENCE, 2021, 41 : 44 - 51
  • [36] Occurrence and fate of microplastics at two different drinking water treatment plants within a river catchment
    Pivokonsky, Martin
    Pivokonska, Lenka
    Novotna, Katerina
    Cermakova, Lenka
    Klimtova, Martina
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 741 (741)
  • [37] Occurrence of microplastics in raw and treated drinking water
    Pivokonsky, Martin
    Cermakova, Lenka
    Novotna, Katerina
    Peer, Petra
    Cajthaml, Tomas
    Janda, Vaclav
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 643 : 1644 - 1651
  • [38] Water treatment plant sludge disposal into stabilization ponds
    Ferreira Filho, Sidney Seckler
    Piveli, Roque Passos
    Cutolo, Silvana Audra
    de Oliveira, Alexandre Alves
    WATER SCIENCE AND TECHNOLOGY, 2013, 67 (05) : 1017 - 1025
  • [39] Adsorption of methylene blue using modified adsorbents from drinking water treatment sludge
    Rashed, M. Nageeb
    El Taher, M. A. El-Daim
    Fadlalla, Somaya M. M.
    WATER SCIENCE AND TECHNOLOGY, 2016, 74 (08) : 1885 - 1898
  • [40] Adsorption of a dye and a real rejection of textile on sludge from drinking water treatement
    Elmontassir, Hasna
    El Falaki, Khadija
    Afdali, Mustapha
    Karhat, Younes
    MOROCCAN JOURNAL OF CHEMISTRY, 2019, 7 (03): : 493 - 505