Separation and determination of components of high level waste using IC and dynamically modified reversed-phase HPLC in 'actinide partitioning' studies using synthetic waste solution

被引:3
作者
Das, Debasis [2 ]
Ansari, S. A. [1 ]
Mohapatra, P. K. [1 ]
Mary, G. [2 ]
Radhakrishnan, K. [2 ]
Tripathi, S. C. [2 ]
Manchnada, V. K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Radiochem, Mumbai 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Fuel Reproc Div, Mumbai 400085, Maharashtra, India
关键词
HPLC; Ion chromatography; ICP-AES; High level waste; Actinide partitioning; PERFORMANCE LIQUID-CHROMATOGRAPHY; COATED COLUMNS; RARE-EARTHS; LANTHANIDES;
D O I
10.1007/s10967-010-0683-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion-chromatography (IC) as well as high performance liquid chromatography (HPLC) techniques have been used as analytical tools for the separation and estimation of some of the relevant metal ions present in the high level liquid waste (HLLW). IC was applied for the estimation of alkali and alkali earth metal ions, viz. Na, Cs, Ba and Sr using methane sulphonic acid as the eluent on a cation exchange column. On the other hand, dynamically modified (with sodium salt of n-octane sulphonic acid) reverse phase HPLC was followed for the estimation of lanthanides viz. La, Pr, Nd and Sm using alpha-hydroxy isobutyric acid as the eluent on a C-18 column. Sample acidity of 0.01 M HNO3 was optimized for best analytical results. The interferences of one group of metal ions on the quantification of the other group of metal ions were studied. The solvent extraction data (distribution coefficient data) of Na, Cs, Sr, Ba, La, Pr, Nd and Sm from their mixture was obtained by analyses of the aqueous samples before and after extraction with extractants used for actinide partitioning, viz., octyl(phenyl) N, Ndiisobutyl carbamoyl methylene phosphine oxide (CMPO), N,N'-dimethyl-N,N'-dibutyl tetradecyl malonamide (DMDB TDMA) and N,N,N',N'-tetraoctyl diglycolamide (TODGA). The solvent extraction data obtained by IC/HPLC techniques was compared with those obtained by ICP-AES technique. A good agreement between the results of the two techniques validated the present analytical method.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 14 条
[1]   Radioactive waste: The size of the problem [J].
Ahearne, JF .
PHYSICS TODAY, 1997, 50 (06) :24-29
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], 2007, RADIOCHEMISTRY NUCL
[4]   DYNAMIC CHROMATOGRAPHIC SYSTEMS FOR THE DETERMINATION OF RARE-EARTHS AND THORIUM IN SAMPLES FROM URANIUM ORE REFINING PROCESSES [J].
BARKLEY, DJ ;
BLANCHETTE, M ;
CASSIDY, RM ;
ELCHUK, S .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2222-2226
[5]   DYNAMIC ION-EXCHANGE CHROMATOGRAPHY FOR THE DETERMINATION OF NUMBER OF FISSIONS IN URANIUM-DIOXIDE FUELS [J].
CASSIDY, RM ;
ELCHUK, S ;
ELLIOT, NL ;
GREEN, LW ;
KNIGHT, CH ;
RECOSKIE, BM .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1181-1186
[6]   DYNAMICALLY COATED COLUMNS FOR THE SEPARATION OF METAL-IONS AND ANIONS BY ION CHROMATOGRAPHY [J].
CASSIDY, RM ;
ELCHUK, S .
ANALYTICAL CHEMISTRY, 1982, 54 (09) :1558-1563
[7]   SEPARATION OF SOME RARE-EARTHS AND TRANSPLUTONIUM ELEMENTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON OSTION CATION EXCHANGER [J].
DUFEK, P ;
VOBECKY, M ;
HOLIK, J ;
VALASEK, J .
JOURNAL OF CHROMATOGRAPHY, 1988, 435 (01) :249-252
[8]   SEPARATION OF THE LANTHANIDES ON HIGH-EFFICIENCY BONDED PHASES AND CONVENTIONAL ION-EXCHANGE RESINS [J].
ELCHUK, S ;
CASSIDY, RM .
ANALYTICAL CHEMISTRY, 1979, 51 (09) :1434-1438
[9]   Optimization conditions for the separation of rare earth elements, americium, curium and cesium with HPLC technique [J].
Goutelard, F. ;
Caussignac, C. ;
Brennetot, R. ;
Stadelmann, G. ;
Gautier, C. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (02) :669-675
[10]  
Jeffery GH., 1996, Vogel's Text book of Quantitative chemical analysis