Disturbance-Observer-Based Control of DFIG in Island Mode for Microgrid Applications

被引:1
作者
Osmanovic, Adnan [1 ]
Uzunovic, Tarik [1 ]
Sabanovic, Asif [2 ]
Velagic, Jasmin [1 ]
机构
[1] Univ Sarajevo, Fac Elect Engn, Sarajevo 71000, Bosnia & Herceg
[2] Int Univ Sarajevo, Fac Engn & Nat Sci, Sarajevo 71210, Bosnia & Herceg
关键词
Doubly fed induction generators; Rotors; Control systems; Stator windings; Generators; Voltage control; Microgrids; Disturbance observer; DFIG; microgrid; renewable energy; wind energy conversion system; island mode operation; DIRECT POWER-CONTROL; FED-INDUCTION-GENERATOR; DIRECT VOLTAGE CONTROL; BACK PWM CONVERTERS; VECTOR CONTROL; ASYMMETRIC LOADS; WIND TURBINES; MACHINE; SYNCHRONIZATION; FREQUENCY;
D O I
10.1109/ACCESS.2021.3124642
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper introduces a novel control approach for Doubly-Fed Induction Generator (DFIG) operating in island mode based on the cascaded control structure with disturbance estimation. The control of the DFIG is a challenging task due to its inherent nonlinearity, fast dynamics, and unpredictable disturbances acting on the system. The proposed control structure involves a nominal controller for plant and disturbance observer (DOB) in each of the inner and outer control loop. The first-order disturbance observers are designed to estimate the time-varying and unknown disturbances. With disturbance estimation, the nominal linear dynamics is obtained in both loops. This enables the same approach for designing controllers for the inner and outer loop which significantly simplifies implementation. The controllers are designed based on the demanded error dynamics and ensure stable operation of the system, while proposed DOBs estimate disturbances including external load. Finally, the effectiveness and quality of the proposed control structure were verified through numerical simulations in terms of external disturbances rejection and closed-loop tracking performance.
引用
收藏
页码:149153 / 149163
页数:11
相关论文
共 38 条
  • [11] Esmaeeli M. R., 2012, J BASIC APPL SCI RES, V2, P11486
  • [12] Direct voltage control of stand-alone DFIG under asymmetric loads based on non-singular terminal sliding mode control and improved extended state observer
    Guo, Lei
    Wang, Dan
    Diao, Liang
    Peng, Zhouhua
    [J]. IET ELECTRIC POWER APPLICATIONS, 2019, 13 (07) : 958 - 968
  • [13] Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder
    Hopfensperger, B
    Atkinson, DJ
    Lakin, RA
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2000, 147 (04): : 241 - 250
  • [14] Sensorless direct voltage control of the stand-alone slip-ring induction generator
    Iwanski, Grzegorz
    Koczara, Wlodzimierz
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (02) : 1237 - 1239
  • [15] Wound rotor induction generator with sensorless control and integrated active filter for feeding nonlinear loads in a stand-alone grid
    Jain, Amit Kumar
    Ranganathan, V. T.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (01) : 218 - 228
  • [16] Krause P. C., ANAL ELECT MACHINERY, V2
  • [17] Leonhard W., 1996, CONTROL ELECT DRIVES, Vsecond
  • [18] Li DY, 2016, CHIN CONTR CONF, P5916, DOI 10.1109/ChiCC.2016.7554284
  • [19] Optimization of Multibrid Permanent-Magnet Wind Generator Systems
    Li, Hui
    Chen, Zhe
    Polinder, Henk
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (01) : 82 - 92
  • [20] Energy-Shaping Controller for DFIG-Based Wind Farm to Mitigate Subsynchronous Control Interaction
    Li, Penghan
    Wang, Jie
    Xiong, Linyun
    Huang, Sunhua
    Ma, Meiling
    Wang, Ziqiang
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (04) : 2975 - 2991