Development and preliminary testing of a standardized method for quantifying excess water in over-hydrated skin using evaporimetry

被引:11
作者
Fader, M. [2 ]
Clark-O'Neill, S. R. [1 ]
Wong, W. K. R. [1 ,3 ]
Runeman, B. [4 ]
Farbrot, A. [4 ]
Cottenden, A. M. [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, Continence & Skin Technol Grp, London WC1E 6BT, England
[2] Univ Southampton, Fac Hlth Sci, Continence Technol & Skin Hlth Grp, Southampton SO17 1BJ, Hants, England
[3] Hong Kong Sanat & Hosp, Dept Radiotherapy, Hong Kong, Peoples R China
[4] SCA Hyg Prod AB, R&D, SE-40503 Gothenburg, Sweden
关键词
diapers; transepidermal water loss; skin hydration; incontinence; STRATUM-CORNEUM HYDRATION; INCONTINENCE; PERFORMANCE; DIAPERS;
D O I
10.1088/0967-3334/32/3/003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Although evaporimetry (the measurement of water vapour flux density from the skin) has often been used to study the impact on skin hydration of using products such as baby diapers and incontinence pads, it is difficult to interpret results and to compare data from different studies because of the diversity of unvalidated methodologies used. The aim of this work was to develop a robust methodology for measuring the excess water in over-hydrated skin and test it on volar forearm and hip skin which had been occluded with saline soaked patches. Three repeat measurements were made on the volar forearm and the hip of five young (31-44 years) and six older (67-85 years) women and moderately good within-subject repeatability was found for both skin sites for both subject groups. Measurements taken from the hip were significantly higher (P = 0.001) than those from the arm and had larger coefficients of variation (3.5-22.1%) compared to arms (3.0-14.0%). There were no significant differences between young and older skin, implying that women for future studies could be recruited without regard to age. This is the first time that a robust evaporimetric methodology for quantifying excess water in over-hydrated skin has been described and validated, and it will form a solid basis for future work.
引用
收藏
页码:305 / 317
页数:13
相关论文
共 15 条
  • [1] BERG RW, 1988, TEXT RES J, V3, P585
  • [2] In vivo confocal Raman microspectroscopy of the skin:: Noninvasive determination of molecular concentration profiles
    Caspers, PJ
    Lucassen, GW
    Carter, EA
    Bruining, HA
    Puppels, GJ
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2001, 116 (03) : 434 - 442
  • [3] Disposable bedpads for incontinence: predicting their clinical leakage properties using laboratory tests
    Cottenden, AM
    Dean, GE
    Brooks, RJ
    Haines-Nutt, RF
    Rothwell, JG
    Penfold, PH
    [J]. MEDICAL ENGINEERING & PHYSICS, 1998, 20 (05): : 347 - 359
  • [4] COMPARISON OF DISPOSABLE DIAPERS WITH FLUFF ABSORBENT AND FLUFF PLUS ABSORBENT POLYMERS - EFFECTS ON SKIN HYDRATION, SKIN PH, AND DIAPER DERMATITIS
    DAVIS, JA
    LEYDEN, JJ
    GROVE, GL
    RAYNOR, WJ
    [J]. PEDIATRIC DERMATOLOGY, 1989, 6 (02) : 102 - 108
  • [5] Review of methods used for quantifying excess water in over-hydrated skin using evaporimetry
    Fader, Mandy
    Clarke-O'Neill, Sinead
    Wong, W. K. Rebecca
    Runeman, Bo
    Farbrot, Anne
    Cottenden, Alan
    [J]. SKIN RESEARCH AND TECHNOLOGY, 2010, 16 (01) : 1 - 8
  • [6] Grove GL, 1998, CURR PROBL DERMATOL, V26, P183
  • [7] INVIVO CUTANEOUS RESPONSE TO FABRIC .5. EFFECT OF FIBER TYPE AND FABRIC MOISTURE-CONTENT ON STRATUM-CORNEUM HYDRATION
    HATCH, KL
    MARKEE, NL
    PRATO, HH
    ZERONIAN, SH
    MAIBACH, HI
    KUEHL, RO
    AXELSON, RD
    [J]. TEXTILE RESEARCH JOURNAL, 1992, 62 (11) : 638 - 647
  • [8] In vivo cutaneous and perceived comfort response to fabric .6. The effect of moist fabrics on stratum corneum hydration
    Hatch, KL
    Prato, HH
    Zeronian, SH
    Maibach, HI
    [J]. TEXTILE RESEARCH JOURNAL, 1997, 67 (12) : 926 - 931
  • [9] Imhof R. E., 2009, International Journal of Cosmetic Science, V31, P97, DOI 10.1111/j.1468-2494.2008.00476.x
  • [10] PINAGODA J, 1990, CONTACT DERMATITIS, V22, P164