Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis

被引:66
作者
Bratke, Grischa [1 ]
Hickethier, Tilman [1 ]
Bar-Ness, Daniel [2 ,3 ]
Bunck, Alexander Christian [1 ]
Maintz, David [1 ]
Pahn, Gregor [4 ]
Coulon, Philippe [5 ]
Si-Mohamed, Salim [2 ,6 ]
Douek, Philippe [2 ,6 ]
Sigovan, Monica [2 ]
机构
[1] Univ Cologne, Dept Radiol, Kerpenerstr 62, D-50937 Cologne, Germany
[2] Univ Claude Bernard Lyon 1, INSERM, U12063, CNRS,UMR 5220,Creatis Lab, Lyon, France
[3] CERMEP Imagerie Vivant, Lyon, France
[4] Philips GmbH, Healthcare Div, Hamburg, Germany
[5] Philips, CT Clin Sci, Suresnes, France
[6] Hosp Civils Lyon, Radiol Dept, Lyon, France
基金
欧盟地平线“2020”;
关键词
photon-counting; dual energy; computed tomography; CT; stent; cardiac; dual layer; coronary; restenosis; artery; CT ANGIOGRAPHY; REVASCULARIZATION; DIAGNOSIS; OUTCOMES; ENERGY;
D O I
10.1097/RLI.0000000000000610
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives In-stent restenosis (ISR) is one of the main long-term complications after coronary stent placement, and the ability to evaluate ISR noninvasively using coronary computed tomography (CT) angiography remains challenging. For this application, spectral photon-counting CT (SPCCT) has the potential to increase image quality and reduce artifacts due to its advanced detector technology. Our study aimed to verify the technical and clinical potential of a novel SPCCT prototype using an ISR phantom setup. Materials and Methods Soft plaque-like restenosis (45 HU; approximately 50% of the stent lumen) were inserted into 10 different coronary stents (3 mm diameter), which were placed in a vessel phantom and filled with a contrast agent (400 HU). A research prototype SPCCT and a clinical dual-layer CT (DLCT; IQon; Philips) with comparable acquisition and reconstruction parameters were used to scan the phantoms. Conventional polyenergetic (PolyE) and monoenergetic (MonoE) images with 4 different energy levels (40, 60, 90, 120 keV) were reconstructed. Qualitative (delineation of the stenosis and adjacent residual lumen using a 5-point Likert scale) and quantitative (image noise, visible lumen diameter, lumen diameter adjacent to the stenosis, contrast-to-noise ratio of the restenosis) parameters were evaluated for both systems. Results The qualitative results averaged over all reconstructions were significantly superior for SPCCT compared with DLCT (eg, subjective rating of the best reconstruction of each scanner: DLCT PolyE: 2.80 +/- 0.42 vs SPCCT MonoE 40 keV: 4.25 +/- 1.03). Stenosis could be clearly detected in 9 and suspected in 10 of the 10 stents with both SPCCT and DLCT. The residual lumen next to the stenosis was clearly delineable in 7 of 10 stents (0.64 +/- 0.11 mm or 34.97% of the measured stent lumen) with SPCCT, while it was not possible to delineate the residual lumen for all stents using DLCT. The measured diameter of the lumen within the stent was significantly higher for SPCCT compared with DLCT in all reconstructions with the best results for the MonoE 40 keV images (SPCCT: 1.80 +/- 0.17 mm; DLCT: 1.50 +/- 0.31 mm). The image noise and the contrast-to-noise ratio were better for DLCT than for SPCCT (contrast-to-noise ratio: DLCT MonoE 40: 31.58 +/- 12.54; SPCCT MonoE 40: 4.64 +/- 1.30). Conclusions Spectral photon-counting CT allowed for the noninvasive evaluation of ISR with reliable results regarding the residual lumen for most tested stents and the clear identification or suspicion of stenosis for all stents. In contrast, the residual lumen could not be detected for a single stent using DLCT.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 25 条
[1]   Optimal scanning protocols of 64-slice CT angiography in coronary artery stents: An in vitro phantom study [J].
Almutairi, Abdulrahman Marzouq ;
Sun, Zhonghua ;
Ng, Curtise ;
Al-Safran, Zakariya A. ;
Al-Mulla, Abeer A. ;
Al-Jamaan, Abdulaziz I. .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (01) :156-160
[2]  
Alraies MC, 2017, WORLD J CARDIOL, V9, P640, DOI 10.4330/wjc.v9.i8.640
[3]   In-stent restenosis: Long-term outcome and predictors of subsequent target lesion revascularization after repeat balloon angioplasty [J].
Bossi, I ;
Klersy, C ;
Black, AJ ;
Cortina, R ;
Choussat, R ;
Cassagneau, B ;
Jordan, C ;
Laborde, JC ;
Laurent, JP ;
Bernies, M ;
Fajadet, J ;
Marco, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) :1569-1576
[4]   Bare metal stent restenosis is not a benign clinical entity [J].
Chen, Michael S. ;
John, Jim M. ;
Chew, Derek P. ;
Lee, David S. ;
Ellis, Stephen G. ;
Bhatt, Deepak L. .
AMERICAN HEART JOURNAL, 2006, 151 (06) :1260-1264
[5]   Poly-energetic and virtual mono-energetic images from a novel dual-layer spectral detector CT: optimization of window settings is crucial to improve subjective image quality in abdominal CT angiographies [J].
Doerner, Jonas ;
Luetkens, Julian A. ;
Iuga, Andra-Iza ;
Byrtus, Jonathan ;
Haneder, Stefan ;
Maintz, David ;
Hickethier, Tilman .
ABDOMINAL RADIOLOGY, 2018, 43 (03) :742-750
[6]   Coronary CT angiography (CCTA) using third-generation dual-source CT for ruling out in-stent restenosis [J].
Eckert, J. ;
Renczes-Janetzko, P. ;
Schmidt, M. ;
Magedanz, A. ;
Voigtlaender, T. ;
Schmermund, A. .
CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (04) :402-410
[7]   Monoenergetic reconstructions for imaging of coronary artery stents using spectral detector CT: In-vitro experience and comparison to conventional images [J].
Hickethier, Tilman ;
Baessler, Bettina ;
Kroeger, Jan Robert ;
Doerner, Jonas ;
Pahn, Gregor ;
Maintz, David ;
Michels, Guido ;
Bunck, Alexander C. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (01) :33-39
[8]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[9]   Evaluation of a preclinical photon-counting CT prototype for pulmonary imaging [J].
Kopp, Felix K. ;
Daerr, Heiner ;
Si-Mohamed, Salim ;
Sauter, Andreas P. ;
Ehn, Sebastian ;
Fingerle, Alexander A. ;
Brendel, Bernhard ;
Pfeiffer, Franz ;
Roessl, Ewald ;
Rummeny, Ernst J. ;
Pfeiffer, Daniela ;
Proksa, Roland ;
Douek, Philippe ;
Noel, Peter B. .
SCIENTIFIC REPORTS, 2018, 8
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;