Cantilever spring constant calibration using laser Doppler vibrometry

被引:115
作者
Ohler, Benjamin [1 ]
机构
[1] Veeco Instruments, Santa Barbara, CA 93117 USA
关键词
D O I
10.1063/1.2743272
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Uncertainty in cantilever spring constants is a critical issue in atomic force microscopy (AFM) force measurements. Though numerous methods exist for calibrating cantilever spring constants, the accuracy of these methods can be limited by both the physical models themselves as well as uncertainties in their experimental implementation. Here we report the results from two of the most common calibration methods, the thermal tune method and the Sader method. These were implemented on a standard AFM system as well as using laser Doppler vibrometry (LDV). Using LDV eliminates some uncertainties associated with optical lever detection on an AFM. It also offers considerably higher signal to noise deflection measurements. We find that AFM and LDV result in similar uncertainty in the calibrated spring constants, about 5%, using either the thermal tune or Sader methods provided that certain limitations of the methods and instrumentation are observed. (c) 2007 American Institute of Physics.
引用
收藏
页数:5
相关论文
共 25 条
[1]  
ALEXANDER L, 1988, J APPL PHYS, V65, P164
[2]   High-precision laser vibrometers based on digital Doppler-signal processing [J].
Bauer, M ;
Ritter, F ;
Siegmund, G .
FIFTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2002, 4827 :50-61
[3]   Comparison of calibration methods for atomic-force microscopy cantilevers [J].
Burnham, NA ;
Chen, X ;
Hodges, CS ;
Matei, GA ;
Thoreson, EJ ;
Roberts, CJ ;
Davies, MC ;
Tendler, SJB .
NANOTECHNOLOGY, 2003, 14 (01) :1-6
[4]   Force measurements with the atomic force microscope: Technique, interpretation and applications [J].
Butt, HJ ;
Cappella, B ;
Kappl, M .
SURFACE SCIENCE REPORTS, 2005, 59 (1-6) :1-152
[5]   CALCULATION OF THERMAL NOISE IN ATOMIC-FORCE MICROSCOPY [J].
BUTT, HJ ;
JASCHKE, M .
NANOTECHNOLOGY, 1995, 6 (01) :1-7
[6]   A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY [J].
CLEVELAND, JP ;
MANNE, S ;
BOCEK, D ;
HANSMA, PK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) :403-405
[7]   Practical implementation of dynamic methods for measuring atomic force microscope cantilever spring constants [J].
Cook, S. M. ;
Schaeffer, T. E. ;
Chynoweth, K. M. ;
Wigton, M. ;
Simmonds, R. W. ;
Lang, K. M. .
NANOTECHNOLOGY, 2006, 17 (09) :2135-2145
[8]   ATOMIC FORCE MICROSCOPY USING OPTICAL INTERFEROMETRY [J].
ERLANDSSON, R ;
MCCLELLAND, GM ;
MATE, CM ;
CHIANG, S .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1988, 6 (02) :266-270
[9]   Comment on tilt of atomic force microscope cantilevers: effect on spring constant and adhesion measurements [J].
Hutter, JL .
LANGMUIR, 2005, 21 (06) :2630-2632
[10]   CALIBRATION OF ATOMIC-FORCE MICROSCOPE TIPS [J].
HUTTER, JL ;
BECHHOEFER, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (07) :1868-1873