Seismic strengthening of shear critical post-heated circular concrete columns wrapped with FRP composite jackets

被引:23
作者
Bailey, C. G. [1 ]
Yaqub, M. [2 ]
机构
[1] Univ Manchester, Fac Engn & Phys Sci, Manchester M13 9PL, Lancs, England
[2] Univ Engn & Technol, Taxila, Pakistan
关键词
Columns; Heat; FRP; Cyclic load; RC COLUMNS; PERFORMANCE; RETROFIT; BEHAVIOR; DUCTILITY;
D O I
10.1016/j.compstruct.2011.09.004
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
An experimental study was carried out to investigate the seismic performance of post-heated circular reinforced concrete columns wrapped with glass or carbon fibre reinforced polymer jackets. Eight shear critical reinforced circular columns with a shear span-to-depth ratio of 2.5 were tested under a combined constant axial and cyclic lateral displacement history, simulating earthquake loading. The columns were tested in three groups, unheated, post-heated and post-heated repaired with either glass fibre reinforced polymer (GFRP) or carbon fibre reinforced polymer (CFRP). In terms of seismic performance the test results indicated that using GFRP or CFRP jackets significantly increased the shear capacity, ductility and energy dissipation of the post-heated damaged columns. However, the GFRP or CFRP did not increase the stiffness of the post-heated damaged columns. It was found that the unheated and post-heated damaged columns failed in a brittle shear mode while the mode of failure of posted-heated columns repaired with GFRP or CFRP was successfully shifted from a shear to a ductile flexural failure. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:851 / 864
页数:14
相关论文
共 37 条
[1]  
[Anonymous], ACI SPEC PUBL
[2]   Hysteretic Behavior of bridge columns with FRP-Jacketed lap splices designed for moderate ductility enhancement [J].
Brena, Sergio F. ;
Schlick, Benjamin M. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (06) :565-574
[3]   Residual behavior of fire-exposed reinforced concrete beams prestrengthened in flexure with fiber-reinforced polymer sheets [J].
Chowdhury, E. U. ;
Bisby, L. A. ;
Green, M. F. ;
Kodur, V. K. R. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (01) :61-68
[4]   Investigation of insulated FRP-wrapped reinforced concrete columns in fire [J].
Chowdhury, Ershad U. ;
Bisby, Luke A. ;
Green, Mark F. ;
Kodur, Venkatesh K. R. .
FIRE SAFETY JOURNAL, 2007, 42 (6-7) :452-460
[5]  
Chung YS, 2008, ACI STRUCT J, V105, P87
[6]   Seismic retrofit of reinforced concrete short columns by CFRP materials [J].
Colomb, F. ;
Tobbi, H. ;
Ferrier, E. ;
Hamelin, P. .
COMPOSITE STRUCTURES, 2008, 82 (04) :475-487
[7]  
Flores LM, 2003, PERFORMANCE EXISTING
[8]   FRP confined concrete columns: Behaviour under extreme conditions [J].
Green, Mark F. ;
Bisby, Luke A. ;
Fam, Amir Z. ;
Kodur, Venkatesh K. R. .
CEMENT & CONCRETE COMPOSITES, 2006, 28 (10) :928-937
[9]   Seismic behavior of RC columns with bond-critical regions: Criteria for bond strengthening using external FRP jackets [J].
Harajli, M. H. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (01) :69-79
[10]  
Harajli MH, 2008, ACI STRUCT J, V105, P760