Quantification of fractional flow reserve based on angiographic image data

被引:18
|
作者
Wong, Jerry T. [1 ]
Le, Huy [1 ]
Suh, William M. [2 ]
Chalyan, David A. [1 ]
Mehraien, Toufan [1 ]
Kern, Morton J. [2 ]
Kassab, Ghassan S. [3 ]
Molloi, Sabee [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Div Cardiol, Dept Med, Irvine, CA 92868 USA
[3] Indiana Purdue Univ, Dept Biomed Engn, Indianapolis, IN 46202 USA
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2012年 / 28卷 / 01期
关键词
Angiography; Blood flow; Blood volume; Regional blood flow; Stenosis; CORONARY BLOOD-FLOW; DIGITAL-SUBTRACTION-ANGIOGRAPHY; PRESSURE SLOPE INDEX; IN-VIVO VALIDATION; ARTERIAL-PRESSURE; SCALING LAWS; MAXIMUM VASODILATION; HYPEREMIC FLOW; LUMEN VOLUME; HEART-RATE;
D O I
10.1007/s10554-010-9767-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary angiography provides excellent visualization of coronary arteries, but has limitations in assessing the clinical significance of a coronary stenosis. Fractional flow reserve (FFR) has been shown to be reliable in discerning stenoses responsible for inducible ischemia. The purpose of this study is to validate a technique for FFR quantification using angiographic image data. The study was carried out on 10 anesthetized, closed-chest swine using angioplasty balloon catheters to produce partial occlusion. Angiography based FFR was calculated from an angiographically measured ratio of coronary blood flow to arterial lumen volume. Pressure-based FFR was measured from a ratio of distal coronary pressure to aortic pressure. Pressure-wire measurements of FFR (FFR (P) ) correlated linearly with angiographic volume-derived measurements of FFR (FFR (V) ) according to the equation: FFR (P) = 0.41 FFR (V) + 0.52 (P-value < 0.001). The correlation coefficient and standard error of estimate were 0.85 and 0.07, respectively. This is the first study to provide an angiographic method to quantify FFR in swine. Angiographic FFR can potentially provide an assessment of the physiological severity of a coronary stenosis during routine diagnostic cardiac catheterization without a need to cross a stenosis with a pressure-wire.
引用
收藏
页码:13 / 22
页数:10
相关论文
共 50 条
  • [21] 1.5 and 3 Tesla quantification of myocardial perfusion reserve in comparison to fractional flow reserve
    Peter Bernhardt
    Thomas Walcher
    Wolfgang Rottbauer
    Jochen Wöhrle
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [22] Quantification of myocardial perfusion reserve at 1.5 and 3.0 Tesla: a comparison to fractional flow reserve
    Peter Bernhardt
    Thomas Walcher
    Wolfgang Rottbauer
    Jochen Wöhrle
    The International Journal of Cardiovascular Imaging, 2012, 28 : 2049 - 2056
  • [23] Angiographic Findings and Post-Percutaneous Coronary Intervention Fractional Flow Reserve
    Zhang, Jinlong
    Hwang, Doyeon
    Yang, Seokhun
    Hu, Xinyang
    Lee, Joo Myung
    Nam, Chang-Wook
    Shin, Eun-Seok
    Doh, Joon-Hyung
    Hoshino, Masahiro
    Hamaya, Rikuta
    Kanaji, Yoshihisa
    Murai, Tadashi
    Zhang, Jun-Jie
    Ye, Fei
    Li, Xiaobo
    Ge, Zhen
    Chen, Shao-Liang
    Kakuta, Tsunekazu
    Wang, Jian'an
    Koo, Bon-Kwon
    JAMA NETWORK OPEN, 2024, 7 (06) : e2418072
  • [24] Angiographic Fractional Flow Reserve Easier, Potentially Faster, and Less Invasive But Is it Better?
    Allana, Salman S.
    Sandoval, Yader
    Brilakis, Emmanouil S.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (14) : 1791 - 1793
  • [25] Estimation of fractional flow reserve in patients with intermediate coronary artery disease; usefulness of estimated fractional flow reserve value by using clinical and angiographic factors
    Watanabe, H.
    Iwanaga, Y.
    Kakehi, K.
    Ikeda, T.
    Takase, T.
    Yamaji, K.
    Ueno, M.
    Kobuke, K.
    Miyazaki, S.
    EUROPEAN HEART JOURNAL, 2018, 39 : 762 - 762
  • [26] Validation Study of Image-Based Fractional Flow Reserve During Coronary Angiography
    Pellicano, Mariano
    Lavi, Ifat
    De Bruyne, Bernard
    Vaknin-Assa, Hana
    Assali, Abid
    Valtzer, Orna
    Lotringer, Yonit
    Weisz, Giora
    Almagor, Yaron
    Xaplanteris, Panagiotis
    Kirtane, Ajay J.
    Codner, Pablo
    Leon, Martin B.
    Kornowski, Ran
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (09)
  • [27] Clinical and Angiographic Factors Contributing to Discrepancy Between Angiographic and Fractional Flow Reserve Estimation in Intermediate Coronary Stenosis
    Kazuyoshi, Kakehi
    Iwanaga, Yoshitaka
    Watanabe, Heitaro
    Ueno, Masafumi
    Ikeda, Tomoyuki
    Takase, Toru
    Yamaji, Kenji
    Kobuke, Kazuhiro
    Miyazaki, Shunichi
    CIRCULATION, 2017, 136
  • [28] Research progress on image-based calculation of coronary artery fractional flow reserve
    Sun Z.
    Jiao W.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2023, 40 (01): : 171 - 179
  • [29] Coronary flow reserve and fractional flow reserve
    Ozyol, Ali
    Yilmaz, Mehmet Birhan
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2007, 35 (04): : 253 - 261
  • [30] Quantification of disturbed coronary flow by disturbed vorticity index and relation with fractional flow reserve
    Chu, Miao
    von Birgelen, Clemens
    Li, Yingguang
    Westra, Jelmer
    Yang, Junqing
    Holm, Niels R.
    Reiber, Johan H. C.
    Wijns, William
    Tu, Shengxian
    ATHEROSCLEROSIS, 2018, 273 : 136 - 144