Quantification of fractional flow reserve based on angiographic image data

被引:18
|
作者
Wong, Jerry T. [1 ]
Le, Huy [1 ]
Suh, William M. [2 ]
Chalyan, David A. [1 ]
Mehraien, Toufan [1 ]
Kern, Morton J. [2 ]
Kassab, Ghassan S. [3 ]
Molloi, Sabee [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Div Cardiol, Dept Med, Irvine, CA 92868 USA
[3] Indiana Purdue Univ, Dept Biomed Engn, Indianapolis, IN 46202 USA
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2012年 / 28卷 / 01期
关键词
Angiography; Blood flow; Blood volume; Regional blood flow; Stenosis; CORONARY BLOOD-FLOW; DIGITAL-SUBTRACTION-ANGIOGRAPHY; PRESSURE SLOPE INDEX; IN-VIVO VALIDATION; ARTERIAL-PRESSURE; SCALING LAWS; MAXIMUM VASODILATION; HYPEREMIC FLOW; LUMEN VOLUME; HEART-RATE;
D O I
10.1007/s10554-010-9767-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary angiography provides excellent visualization of coronary arteries, but has limitations in assessing the clinical significance of a coronary stenosis. Fractional flow reserve (FFR) has been shown to be reliable in discerning stenoses responsible for inducible ischemia. The purpose of this study is to validate a technique for FFR quantification using angiographic image data. The study was carried out on 10 anesthetized, closed-chest swine using angioplasty balloon catheters to produce partial occlusion. Angiography based FFR was calculated from an angiographically measured ratio of coronary blood flow to arterial lumen volume. Pressure-based FFR was measured from a ratio of distal coronary pressure to aortic pressure. Pressure-wire measurements of FFR (FFR (P) ) correlated linearly with angiographic volume-derived measurements of FFR (FFR (V) ) according to the equation: FFR (P) = 0.41 FFR (V) + 0.52 (P-value < 0.001). The correlation coefficient and standard error of estimate were 0.85 and 0.07, respectively. This is the first study to provide an angiographic method to quantify FFR in swine. Angiographic FFR can potentially provide an assessment of the physiological severity of a coronary stenosis during routine diagnostic cardiac catheterization without a need to cross a stenosis with a pressure-wire.
引用
收藏
页码:13 / 22
页数:10
相关论文
共 50 条
  • [1] Quantification of fractional flow reserve based on angiographic image data
    Jerry T. Wong
    Huy Le
    William M. Suh
    David A. Chalyan
    Toufan Mehraien
    Morton J. Kern
    Ghassan S. Kassab
    Sabee Molloi
    The International Journal of Cardiovascular Imaging, 2012, 28 : 13 - 22
  • [2] Quantification of Fractional Flow Reserve Using Angiographic Image Data
    Molloi, S.
    Wong, J. T.
    Chalyan, D. A.
    Le, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 901 - 904
  • [3] QUANTIFICATION OF CORONARY FRACTIONAL FLOW RESERVE USING ANGIOGRAPHIC IMAGE DATA
    Zhang, Zhang
    Takarada, Shigeho
    Molloi, Sabee
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1872 - E1872
  • [4] Quantification of absolute coronary flow reserve and relative fractional flow reserve in a swine animal model using angiographic image data
    Zhang, Zhang
    Takarada, Shigeho
    Molloi, Sabee
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2012, 303 (03): : H401 - H410
  • [5] QUANTIFICATION OF CORONARY FLOW RESERVE FOR MICROCIRCULATION ASSESSMENT USING ANGIOGRAPHIC IMAGE DATA
    Zhang, Zhang
    Takarada, Shigeho
    Molloi, Sabee
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1873 - E1873
  • [6] Coronary Angiographic Characteristics That Influence Fractional Flow Reserve
    Natsumeda, Makoto
    Nakazawa, Gaku
    Murakami, Tsutomu
    Torii, Sho
    Ijichi, Takeshi
    Ohno, Yohei
    Masuda, Naoki
    Shinozaki, Norihiko
    Ogata, Nobuhiko
    Yoshimachi, Fuminobu
    Ikari, Yuji
    CIRCULATION JOURNAL, 2015, 79 (04) : 802 - 807
  • [7] Letter to the editor: "A novel angiographic fractional flow reserve"
    Qi, Xiaolong
    Fan, Guoxin
    Yang, Changqing
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2013, 304 (08): : H1175 - H1175
  • [8] Prediction of fractional flow reserve with angiographic DILEMMA score
    Beton, Osman
    Kaya, Hakki
    Turgut, Okan Onur
    Yilmaz, Mehmet Birhan
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2017, 17 (04): : 285 - 292
  • [9] A Poiseuille-based coronary angiographic index for prediction of fractional flow reserve
    Jaffe, Ronen
    Halon, David A.
    Roguin, Ariel
    Rubinshtein, Ronen
    Lewis, Basil S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (03) : 862 - 865
  • [10] Diagnostic Performance of Automated Artificial IntelligenceBased Angiographic Fractional Flow Reserve Compared With Invasive Fractional Flow Reserve
    Omori, Hiroyuki
    Otani, Katharina
    Berger, Martin
    Itu, Lucian
    Tanigaki, Toru
    Kawase, Yoshiaki
    Noda, Toshiyuki
    Matsuo, Hitoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B108 - B108