Comparison of Aortic Annulus Dimension After Aortic Valve Neocuspidization With Valve Replacement and Normal Valve

被引:21
作者
Yamamoto, Yoshitaka [1 ]
Iino, Kenji [1 ]
Shintani, Yoshiko [1 ]
Kato, Hiroki [1 ]
Kimura, Keiichi [1 ]
Watanabe, Go [2 ]
Takemura, Hirofumi [1 ]
机构
[1] Kanazawa Univ, Dept Thorac Cardiovasc & Gen Surg, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
[2] New Heart Watanabe Inst, Suginami Ku, Tokyo, Japan
关键词
aortic valve neocuspidization; aortic valve replacement; multidetector computed tomography; aortic annulus motion; MULTIDETECTOR COMPUTED-TOMOGRAPHY; AUTOLOGOUS PERICARDIUM; ROOT; RECONSTRUCTION; IMPLANTATION; REGURGITATION; DIASTOLE; OUTCOMES; SYSTOLE; IMPACT;
D O I
10.1053/j.semtcvs.2016.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aortic valve replacement (AVR) remains the standard surgical intervention for aortic valve disease and is preferred by many surgeons, despite its associated clinical issues. The clinical efficacy of aortic valve neocuspidization (AVNeo) with glutaraldehyde-treated autologous pericardium, the Ozaki procedure, has recently been reported. Although it is presumed to preserve the normal aortic annulus motion, changes to the aortic annulus during the cardiac cycle after AVNeo remain unclear. From March to December 2014, aortic annular dimensions were measured for 23 patients; the sample included 8 patients who had undergone AVNeo, 10 patients with normal aortic valves, and 5 patients who had undergone AVR. Measurements were recorded using electrocardiography-gated multidetector computed tomography. Data were analyzed using automated aortic root analysis software. Postoperative peak pressure gradients for the AVNeo and AVR groups were compared. No statistically significant differences in annulus variation were observed between patients who had undergone AVNeo and those with normal aortic valves. Annular area was larger during systole than during diastole in both groups. Postoperative peak pressure gradients were significantly lower in the AVNeo group than in the AVR group. The results of the present study demonstrated that aortic annular dimensions after AVNeo are similar to the dimensions of normal aortic valves. This was evidenced using electrocardiography-gated multidetector computed tomography, previously reported as the most reliable method, to evaluate annulus motion during the cardiac cycle. Lower postoperative peak pressure gradients might underlie the observed changes. These advantages will help in rectifying AVR defects. © 2016 Elsevier Inc.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 26 条
  • [11] Incidence and Outcomes of Contrast-Induced Nephropathy After Computed Tomography in Patients With CKD: A Quality Improvement Report
    Kim, Sun Moon
    Cha, Ran-hui
    Lee, Jung Pyo
    Kim, Dong Ki
    Oh, Kook-Hwan
    Joo, Kwon Wook
    Lim, Chun Soo
    Kim, Suhnggwon
    Kim, Yon Su
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2010, 55 (06) : 1018 - 1025
  • [12] A four-dimensional study of the aortic root dynamics
    Lansac, E
    Lim, HS
    Shomura, Y
    Lim, KH
    Rice, NT
    Goetz, W
    Acar, C
    Duran, CMG
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (04) : 497 - 503
  • [13] Manual, semiautomated, and fully automated measurement of the aortic annulus for planning of transcatheter aortic valve replacement (TAVR/TAVI): Analysis of interchangeability
    Lou, Junyang
    Obuchowski, Nancy A.
    Krishnaswamy, Amar
    Popovic, Zoran
    Flamm, Scott D.
    Kapadia, Samir R.
    Svensson, Lars G.
    Bolen, Michael A.
    Desai, Milind Y.
    Halliburton, Sandra S.
    Tuzcu, E. Murat
    Schoenhagen, Paul
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (01) : 42 - 49
  • [14] Ozaki S, 2000, J HEART VALVE DIS, V9, P552
  • [15] Reconstruction of Bicuspid Aortic Valve With Autologous Pericardium - Usefulness of Tricuspidization -
    Ozaki, Shigeyuki
    Kawase, Isamu
    Yamashita, Hiromasa
    Uchida, Shin
    Nozawa, Yukinari
    Takatoh, Mikio
    Hagiwara, So
    Kiyohara, Nagaki
    [J]. CIRCULATION JOURNAL, 2014, 78 (05) : 1144 - 1151
  • [16] A total of 404 cases of aortic valve reconstruction with glutaraldehyde-treated autologous pericardium
    Ozaki, Shigeyuki
    Kawase, Isamu
    Yamashita, Hiromasa
    Uchida, Shin
    Nozawa, Yukinari
    Takatoh, Mikio
    Hagiwara, So
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (01) : 301 - 306
  • [17] Aortic valve reconstruction using self-developed aortic valve plasty system in aortic valve disease
    Ozaki, Shigeyuki
    Kawase, Isamu
    Yamashita, Hiromasa
    Uchida, Shin
    Nozawa, Yukinari
    Matsuyama, Takayoshi
    Takatoh, Mikio
    Hagiwara, So
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 12 (04) : 550 - 553
  • [18] Incidence and Predictors of Early and Late Mortality After Transcatheter Aortic Valve Implantation in 663 Patients With Severe Aortic Stenosis
    Tamburino, Corrado
    Capodanno, Davide
    Ramondo, Angelo
    Petronio, Anna Sonia
    Ettori, Federica
    Santoro, Gennaro
    Klugmann, Silvio
    Bedogni, Francesco
    Maisano, Francesco
    Marzocchi, Antonio
    Poli, Arnaldo
    Antoniucci, David
    Napodano, Massimo
    De Carlo, Marco
    Fiorina, Claudia
    Ussia, Gian Paolo
    [J]. CIRCULATION, 2011, 123 (03) : 299 - 308
  • [19] THUBRIKAR M, 1979, J THORAC CARDIOV SUR, V77, P863
  • [20] NORMAL AORTIC-VALVE FUNCTION IN DOGS
    THUBRIKAR, M
    HARRY, R
    NOLAN, SP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1977, 40 (04) : 563 - 568