Comparison of Aortic Annulus Dimension After Aortic Valve Neocuspidization With Valve Replacement and Normal Valve

被引:21
作者
Yamamoto, Yoshitaka [1 ]
Iino, Kenji [1 ]
Shintani, Yoshiko [1 ]
Kato, Hiroki [1 ]
Kimura, Keiichi [1 ]
Watanabe, Go [2 ]
Takemura, Hirofumi [1 ]
机构
[1] Kanazawa Univ, Dept Thorac Cardiovasc & Gen Surg, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
[2] New Heart Watanabe Inst, Suginami Ku, Tokyo, Japan
关键词
aortic valve neocuspidization; aortic valve replacement; multidetector computed tomography; aortic annulus motion; MULTIDETECTOR COMPUTED-TOMOGRAPHY; AUTOLOGOUS PERICARDIUM; ROOT; RECONSTRUCTION; IMPLANTATION; REGURGITATION; DIASTOLE; OUTCOMES; SYSTOLE; IMPACT;
D O I
10.1053/j.semtcvs.2016.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aortic valve replacement (AVR) remains the standard surgical intervention for aortic valve disease and is preferred by many surgeons, despite its associated clinical issues. The clinical efficacy of aortic valve neocuspidization (AVNeo) with glutaraldehyde-treated autologous pericardium, the Ozaki procedure, has recently been reported. Although it is presumed to preserve the normal aortic annulus motion, changes to the aortic annulus during the cardiac cycle after AVNeo remain unclear. From March to December 2014, aortic annular dimensions were measured for 23 patients; the sample included 8 patients who had undergone AVNeo, 10 patients with normal aortic valves, and 5 patients who had undergone AVR. Measurements were recorded using electrocardiography-gated multidetector computed tomography. Data were analyzed using automated aortic root analysis software. Postoperative peak pressure gradients for the AVNeo and AVR groups were compared. No statistically significant differences in annulus variation were observed between patients who had undergone AVNeo and those with normal aortic valves. Annular area was larger during systole than during diastole in both groups. Postoperative peak pressure gradients were significantly lower in the AVNeo group than in the AVR group. The results of the present study demonstrated that aortic annular dimensions after AVNeo are similar to the dimensions of normal aortic valves. This was evidenced using electrocardiography-gated multidetector computed tomography, previously reported as the most reliable method, to evaluate annulus motion during the cardiac cycle. Lower postoperative peak pressure gradients might underlie the observed changes. These advantages will help in rectifying AVR defects. © 2016 Elsevier Inc.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 26 条
  • [1] Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    Abdel-Wahab, Mohamed
    Zahn, Ralf
    Horack, Martin
    Gerckens, Ulrich
    Schuler, Gerhard
    Sievert, Horst
    Eggebrecht, Holger
    Senges, Jochen
    Richardt, Gert
    [J]. HEART, 2011, 97 (11) : 899 - 906
  • [2] The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial
    Binder, Ronald K.
    Webb, John G.
    Willson, Alexander B.
    Urena, Marina
    Hansson, Nicolaj C.
    Norgaard, Bjarne L.
    Pibarot, Philippe
    Barbanti, Marco
    Larose, Eric
    Freeman, Melanie
    Dumont, Eric
    Thompson, Chris
    Wheeler, Miriam
    Moss, Robert R.
    Yang, Tae-hyun
    Pasian, Sergio
    Hague, Cameron J.
    Giang Nguyen
    Raju, Rekha
    Toggweiler, Stefan
    Min, James K.
    Wood, David A.
    Rodes-Cabau, Josep
    Leipsic, Jonathon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (05) : 431 - 438
  • [3] Semiautomated Quantification of Aortic Annulus Dimensions on Cardiac CT for TAVR
    Blanke, Philipp
    Spira, Eva Maria
    Ionasec, Razvan
    Meinel, Felix G.
    Ebersberger, Ullrich
    Scheuering, Michael
    Canstein, Christian
    Flohr, Thomas G.
    Langer, Mathias
    Schoepf, U. Joseph
    [J]. JACC-CARDIOVASCULAR IMAGING, 2014, 7 (03) : 320 - 322
  • [4] BREWER RJ, 1976, J THORAC CARDIOV SUR, V72, P413
  • [5] Dagum P, 1999, CIRCULATION, V100, P54
  • [6] Pulsatile Distention of the Nondiseased and Stenotic Aortic Valve Annulus: Analysis With Electrocardiogram-Gated Computed Tomography
    de Heer, Linda M.
    Budde, Ricardo P. J.
    van Prehn, Joffrey
    Mali, Willem P. Th M.
    Bartels, Lambertus W.
    Stella, Pieter R.
    van Herwerden, Lex A.
    Kluin, Jolanda
    Vincken, Koen L.
    [J]. ANNALS OF THORACIC SURGERY, 2012, 93 (02) : 516 - 522
  • [7] Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography
    de Heer, Linda M.
    Budde, Ricardo P. J.
    Mali, Willem P. Th. M.
    de Vos, Alexander M.
    van Herwerden, Lex A.
    Kluin, Jolanda
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (08) : 1195 - 1204
  • [8] Impact of Post-Procedural Aortic Regurgitation on Mortality After Transcatheter Aortic Valve Implantation
    Hayashida, Kentaro
    Lefevre, Thierry
    Chevalier, Bernard
    Hovasse, Thomas
    Romano, Mauro
    Garot, Philippe
    Bouvier, Erik
    Farge, Arnaud
    Donzeau-Gouge, Patrick
    Cormier, Bertrand
    Morice, Marie-Claude
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (12) : 1247 - 1256
  • [9] Aortic valve reconstruction with autologous pericardium for dialysis patients†
    Kawase, Isamu
    Ozaki, Shigeyuki
    Yamashita, Hiromasa
    Uchida, Shin
    Nozawa, Yukinari
    Matsuyama, Takayoshi
    Takatoh, Mikio
    Hagiwara, So
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 16 (06) : 738 - 742
  • [10] Kazui T, 2006, J HEART VALVE DIS, V15, P617