摘要
In order to understand the dynamics of large neural networks, where information is widely distributed over thousands of cells, one of today's challenges is to successfully record the simultaneous activities of as many neurons as possible. This is made possible by using microelectrodes arrays (MEAs) positioned in contact with the neural tissue. Thanks to microelectronics' microfabrication technologies, it now becomes possible to build high density MEAs containing several hundreds of microelectrodes. However, increasing the number of electrodes using conventional electronics is difficult to achieve. Moreover, high density devices addressing all channels independently for simultaneous recording and stimulation are not readily available. Here, we present a 256-channel in vitro MEA system with integrated electronics allowing simultaneous recording and stimulation of neural networks. Both actions are performed independently on all channels.
引用
收藏
页码:171 / +
页数:2
相关论文
共 50 条
  • [11] An Area/Power Efficient Electrode-Matched Neural-Spike Detector Embedded in Implantable 256-Channel MEA
    Hanl, Myungjin
    Ha, Go Eun
    Cheong, Eunji
    Han, Gunhee
    Chae, Youngcheol
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [12] ARGONNE 256-CHANNEL PULSE-HEIGHT ANALYZER
    SCHUMANN, RW
    MCMAHON, JP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (09): : 675 - 685
  • [13] MODIFICATION OF A 256-CHANNEL SCALER FOR NEUROPHYSIOLOGICAL TIME ANALYSIS
    LEVICK, WR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (06): : 660 - &
  • [14] 256-channel reconfigurable system for recording the electrophysiological activity of a neural tissue in vitro
    Zoladz, Miroslaw
    Kmon, Piotr
    Rauza, Jacek
    Grybos, Pawel
    Kowalczyk, Tomasz
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 557 - 560
  • [15] Topography of sleep spindles mapped with 256-channel electroencephalography
    Torassa, T.
    Quiring, J.
    Luu, P.
    Tucker, D.
    SLEEP, 2007, 30 : A25 - A25
  • [16] Low-Loss 256-Channel AWG Module with Monolithically Integrated Spot-Size Converters
    M. Itoh
    S. Kamei
    M. Ishii
    Y. Hida
    T. Shibata
    Y. Hibino
    光学学报, 2003, (S1) : 173 - 174
  • [17] A high-density 256-channel cap for dry electroencephalography
    Fiedler, Patrique
    Fonseca, Carlos
    Supriyanto, Eko
    Zanow, Frank
    Haueisen, Jens
    HUMAN BRAIN MAPPING, 2022, 43 (04) : 1295 - 1308
  • [18] Compact 256-channel multi-well microelectrode array system forin vitroneuropharmacology test
    Kim, Daejeong
    Kang, Hongki
    Nam, Yoonkey
    LAB ON A CHIP, 2020, 20 (18) : 3410 - 3422
  • [19] 256-channel bidirectional optical interconnect using VCSELs and photodiodes on CMOS
    Plant, DV
    Venditti, MB
    Laprise, E
    Faucher, J
    Razavi, K
    Châteauneuf, M
    Kirk, AG
    Ahearn, JS
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2001, 19 (08) : 1093 - 1103
  • [20] AN INVESTIGATION OF SPONTANEOUS CORTICAL SLOW OSCILLATIONS USING 256-CHANNEL EEG
    Gilbert, T. T.
    Luu, P.
    Tucker, D.
    SLEEP, 2010, 33 : A56 - A56