Proportional estimation of finger movements from high-density surface electromyography

被引:52
|
作者
Celadon, Nicolo [1 ]
Dosen, Strahinja [2 ]
Binder, Iris [3 ]
Ariano, Paolo [1 ]
Farina, Dario [2 ]
机构
[1] Fdn Ist Italiano Tecnol, Ctr Sustainable Futures PoliTo, Turin, Italy
[2] Univ Med Ctr Gottingen, Inst Neurorehabil Syst, Gottingen, Germany
[3] Tyromotion GmbH, Graz, Austria
来源
JOURNAL OF NEUROENGINEERING AND REHABILITATION | 2016年 / 13卷
关键词
Surface electromyography; High-Density electrodes; Machine learning; Human-machine interfaces; Rehabilitation robotics; Finger control; Hand rehabilitation; PRIMARY MOTOR CORTEX; MYOELECTRIC CONTROL; INDIVIDUAL FINGER; PROSTHETIC HAND; NEURAL-NETWORK; EMG SIGNALS; STROKE; CLASSIFICATION; ACTIVATION; ROBUST;
D O I
10.1186/s12984-016-0172-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The importance to restore the hand function following an injury/disease of the nervous system led to the development of novel rehabilitation interventions. Surface electromyography can be used to create a user-driven control of a rehabilitation robot, in which the subject needs to engage actively, by using spared voluntary activation to trigger the assistance of the robot. Methods: The study investigated methods for the selective estimation of individual finger movements from high-density surface electromyographic signals (HD-sEMG) with minimal interference between movements of other fingers. Regression was evaluated in online and offline control tests with nine healthy subjects (per test) using a linear discriminant analysis classifier (LDA), a common spatial patterns proportional estimator (CSP-PE), and a thresholding (THR) algorithm. In all tests, the subjects performed an isometric force tracking task guided by a moving visual marker indicating the contraction type (flexion/extension), desired activation level and the finger that should be moved. The outcome measures were mean square error (nMSE) between the reference and generated trajectories normalized to the peak-to-peak value of the reference, the classification accuracy (CA), the mean amplitude of the false activations (MAFA) and, in the offline tests only, the Pearson correlation coefficient (PCORR). Results: The offline tests demonstrated that, for the reduced number of electrodes (<= 24), the CSP-PE outperformed the LDA with higher precision of proportional estimation and less crosstalk between the movement classes (e.g., 8 electrodes, median MAFA similar to 0.6 vs. 1.1 %, median nMSE similar to 4.3 vs. 5.5 %). The LDA and the CSP-PE performed similarly in the online tests (median nMSE < 3.6 %, median MAFA < 0.7 %), but the CSP-PE provided a more stable performance across the tested conditions (less improvement between different sessions). Furthermore, THR, exploiting topographical information about the single finger activity from HD-sEMG, provided in many cases a regression accuracy similar to that of the pattern recognition techniques, but the performance was not consistent across subjects and fingers. Conclusions: The CSP-PE is a method of choice for selective individual finger control with the limited number of electrodes (< 24), whereas for the higher resolution of the recording, either method (CPS-PA or LDA) can be used with a similar performance. Despite the abundance of detection points, the simple THR showed to be significantly worse compared to both pattern recognition/regression methods. Nevertheless, THR is a simple method to apply (no training), and it could still give satisfactory performance in some subjects and/or simpler scenarios (e.g., control of selected fingers). These conclusions are important for guiding future developments towards the clinical application of the methods for individual finger control in rehabilitation robotics.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Proportional estimation of finger movements from high-density surface electromyography
    Nicolò Celadon
    Strahinja Došen
    Iris Binder
    Paolo Ariano
    Dario Farina
    Journal of NeuroEngineering and Rehabilitation, 13
  • [2] Improving the identification of finger movements using high-density surface electromyography pre-processed with PCA
    Yang, Dandan
    Wu, Xiaoying
    Li, Zhengyi
    Zhou, Hui
    Zhou, Dao
    Guan, Jinan
    Xie, Shuiqing
    Hou, Wensheng
    2020 13TH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN (ISCID 2020), 2020, : 249 - 252
  • [3] Estimation of Finger Joint Angle Based on Neural Drive Extracted from High-Density Electromyography
    Dai, Chenyun
    Cao, Yizhou
    Hu, Xiaogang
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4820 - 4823
  • [4] Estimation of Fingertip Forces Using High-Density Surface Electromyography
    Fujikawa, Kaori
    Shirafuji, Shouhei
    Su, Becky
    Piovanelli, Enrico
    Ota, Jun
    2017 INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE (MHS), 2017,
  • [5] Motor unit number estimation using high-density surface electromyography
    van Dijk, Johannes P.
    Blok, Joleen H.
    Lapatki, Bernd G.
    van Schaik, Ivo N.
    Zwarts, Machiel J.
    Stegeman, Dick F.
    CLINICAL NEUROPHYSIOLOGY, 2008, 119 (01) : 33 - 42
  • [6] Motor unit number estimation based on high-density surface electromyography decomposition
    Peng, Yun
    He, Jinbao
    Yao, Bo
    Li, Sheng
    Zhou, Ping
    Zhang, Yingchun
    CLINICAL NEUROPHYSIOLOGY, 2016, 127 (09) : 3059 - 3065
  • [7] Design of a Flexible High-Density Surface Electromyography Sensor
    Feng, Jirou
    Chang, Handdeut
    Jeong, Hwayeong
    Kim, Jung
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4130 - 4133
  • [8] High-density Surface Electromyography as Biomarker of Muscle Aging
    Imrani, Loubna
    Boudaoud, Sofiane
    Lahaye, Clement
    Moreau, Caroline
    Ghezal, Myriam
    Ben Manaa, Safa
    Doulazmi, Mohamed
    Laforet, Jeremy
    Marin, Frederic
    Kinugawa, Kiyoka
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2023, 78 (01): : 25 - 33
  • [9] Analysis of motor units with high-density surface electromyography
    Merletti, Roberto
    Holobar, Ales
    Farina, Dario
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (06) : 879 - 890
  • [10] Transcutaneous innervation zone imaging from high-density surface electromyography recordings
    Liu, Yang
    Zhang, Chuan
    Dias, Nicholas
    Chen, Yen-Ting
    Li, Sheng
    Zhou, Ping
    Zhang, Yingchun
    JOURNAL OF NEURAL ENGINEERING, 2020, 17 (01)