Lumbar intradiscal pressure and whole-body vibration - first results

被引:9
作者
El-Khatib, A [1 ]
Guillon, F [1 ]
机构
[1] Univ Hosp Raymond Poincare, Univ Res Grp Spinal Biomech, F-92380 Garches, France
关键词
whole-body vibration; lumbar spine; intradiscal pressure; posture;
D O I
10.1016/S0268-0033(00)00104-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To contribute to the scientific background for the assessment of the health risk at the lumbar spine from whole-body vibration. Design. Experimental study. Background. Many workers have monitored the vibration at spinal locations on the skin or using skeleton mounted devices in order to assess the vertebral response when sitting. They have shown that resonance occurred in the 4-7 Hz range. Considering the different structures of the intervertebral joint, it seemed interesting to assess their behaviour separately, using intranuclear pressures at the lumbar discs monitored simultaneously with the vertebral accelerations. Methods. Seven unembalmed cadavers were submitted to 5 min. whole-body random vibration, in four seated postures (erect or as in a car, both with or without a lumbar support). Power spectral density functions were estimated at each lumbar level and each posture and the dominant frequency identified. The energy of the pressure signal was also estimated in the 0-25 Hz band. Analysis of variance was then performed to study the effects of subject, disc level, and posture. Results, Energy of the intranuclear pressure variation decreased when leaning the backrest backwards. The effect of the lumbar support depended on the discal level and on posture. The shape of the power spectral density function suggested the existence of a cyclic loading of the nucleus pulposus, while more complex phenomena were observed at the vertebral body. Conclusions. The response of the lumbar spine cannot be assessed by examining only vertebral acceleration at one level.
引用
收藏
页码:S127 / S134
页数:8
相关论文
共 37 条
[1]   Lumbar intradiscal pressure after posterolateral fusion and pedicle screw fixation [J].
Abe, E ;
Nickel, T ;
Buttermann, GR ;
Lewis, JL ;
Transfeldt, EE .
TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1998, 186 (04) :243-253
[2]  
ANDERSSON G, 1974, SCAND J REHABIL MED, V6, P104
[3]  
ANDERSSON GBJ, 1974, SCAND J REHABIL MED, V6, P128
[4]  
ANDERSSON GBJ, 1974, SCAND J REHABIL MED, V6, P122
[5]   An updated review of epidemiologic studies on the relationship between exposure to whole-body vibration and low back pain [J].
Bovenzi, M ;
Hulshof, CTJ .
JOURNAL OF SOUND AND VIBRATION, 1998, 215 (04) :595-611
[6]   THE IMPACT RESPONSE OF THE SEATED SUBJECT [J].
BROMAN, H ;
POPE, MH ;
BENDA, M ;
SVENSSON, M ;
OTTOSSON, C ;
HANSSON, T .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (01) :150-154
[7]   Positive and negative evidence of risk factors for back disorders [J].
Burdorf, A ;
Sorock, G .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1997, 23 (04) :243-256
[8]   Vertical vibration transmission through the lumbar spine of the seated subject - First results [J].
El-Khatib, A ;
Guillon, F ;
Domont, A .
JOURNAL OF SOUND AND VIBRATION, 1998, 215 (04) :763-773
[9]  
ELKHATIB A, 1993, P 14 C INT SOC BIOM
[10]  
ELKHATIB A, 1999, THESIS PARIS 11 U OR