Search Like an Eagle: A Cascaded Model for Insulator Missing Faults Detection in Aerial Images

被引:44
作者
Han, Jiaming [1 ,2 ]
Yang, Zhong [1 ,2 ]
Xu, Hao [1 ,2 ,3 ]
Hu, Guoxiong [4 ]
Zhang, Chi [1 ,2 ]
Li, Hongchen [1 ,2 ]
Lai, Shangxiang [1 ,2 ]
Zeng, Huarong [5 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, 29 Yudao St, Nanjing 211100, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Key Lab Nav Control & Hlth Management Technol Adv, Minist Ind & Informat Technol, 29 Yudao St, Nanjing 211100, Peoples R China
[3] Anhui Univ Technol, Sch Math & Phys, 59 Hudong Rd, Maanshan 243000, Peoples R China
[4] Jiangxi Normal Univ, Sch Software, 437 Beijing West Rd, Nanchang 330022, Jiangxi, Peoples R China
[5] Guizhou Power Grid Co Ltd, Inst Elect Power Sci, 32 Jiefang Rd, Guiyang 550002, Peoples R China
基金
美国国家科学基金会;
关键词
cascaded model; insulator missing fault; vision-based inspection; unmanned aerial vehicle; TRANSMISSION-LINES; RECOGNITION; ACCURATE;
D O I
10.3390/en13030713
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Insulator missing fault is a serious accident of high-voltage transmission lines, which can cause abnormal energy supply. Recently, a lot of vision-based methods are proposed for detecting an insulator missing fault in aerial images. However, these methods usually lack efficiency and robustness due to the effect of the complex background interferences in the aerial images. More importantly, most of these methods cannot address the insulator multi-fault detection. This paper proposes an unprecedented cascaded model to detect insulator multi-fault in the aerial images to solve the existing challenges. Firstly, a total of 764 images are adopted to create a novel insulator missing faults dataset 'IMF-detection'. Secondly, a new network is proposed to locate the insulator string from the complex background. Then, the located region that contains the insulator string is set to be an RoI (region of interest) region. Finally, the YOLO-v3 tiny network is trained and then used to detect the insulator missing faults in the RoI region. Experimental results and analysis validate that the proposed method is more efficient and robust than some previous works. Most importantly, the average running time of the proposed method is about 30ms, which demonstrates that it has the potential to be adopted for the on-line detection of insulator missing faults.
引用
收藏
页数:20
相关论文
共 61 条
[1]  
[Anonymous], THESIS
[2]  
[Anonymous], 2019, J NETW COMPUT APPL
[3]  
[Anonymous], 2018, IEEE C COMPUTER VISI
[4]  
[Anonymous], P IEEE C COMP VIS PA
[5]  
[Anonymous], 2019, P IEEE INT C COMP VI
[6]  
[Anonymous], 2019, ARXIV190308589
[7]  
[Anonymous], 2015, PROC CVPR IEEE
[8]  
[Anonymous], P IEEE C COMP VIS PA
[9]  
[Anonymous], ADV NEURAL INFORM PR
[10]  
[Anonymous], 2017, Journal of Engineering Science and Technology Review, DOI DOI 10.25103/JESTR.104.16