A three-dimensional graphene-based ratiometric signal amplification aptasensor for MUC1 detection

被引:66
作者
Yang, Shaohong [1 ,2 ]
Zhang, Feifei [2 ]
Liang, Qionglin [1 ]
Wang, Zonghua [2 ]
机构
[1] Tsinghua Univ, Dept Chem, MOE Key Lab Bioorgan Phosphorus & Chem Biol, Beijing Key Lab Microanalyt Methods & Instrumenta, Beijing 100084, Peoples R China
[2] Qingdao Univ, Shandong Sinojapanese Ctr Collaborat Res Carbon N, Coll Chem & Chem Engn, Qingdao 266071, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical method; MUC1; detection; Reduced graphene oxide; Ratiometric aptasensor; Signal amplification; Biomarkers detection; PROTEIN BIOMARKER; CANCER-CELLS; IMPEDIMETRIC APTASENSOR; SENSITIVE DETECTION; SENSING PLATFORM; BREAST-CANCER; TUMOR-MARKER; DNA; EXPRESSION; NANOPARTICLES;
D O I
10.1016/j.bios.2018.08.036
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A three-dimensional graphene-based ratiometric signal amplification aptasensor for highly sensitive and selective detection of mucin1 (MUC1) by electrochemical method has been developed. Au-reduced graphene oxide (Au-RGO) composite, which was synthesized through hydrothermal reaction and freeze-drying treatment, was used as substrate for fabricating the sensor interface on glassy carbon electrode (GCE). The application of Au-RGO is beneficial for improving electrochemical performance and immobilizing aptamer. Ferrocene labeled aptamer (Fc-Apt), grafting on Au-RGO composite, worked for specific recognition of MUC1 and as internal reference to improve the detection accuracy. Au nanoparticle modified with methyl blue labeled aptamer (MB-Apt@Au) was adopted to combine with MUC1 that captured on the electrode surface to amplify the electrical signal. Under optimal experimental conditions, this sensor was applied to detect a series concentration of MUC1 solution by alternating current voltammetry method. The aptasensor shows satisfactory detection results with a wide linear range of 1 pM to 1 mu M, a low detection limit of 0.25 pM and good specificity. The good performance of the prepared electrochemical aptasensor implies that this method has potential for MUC1 detection, and it would be promising for early screening and diagnosis of cancer diseases. The proposed method also lays an important foundation for preparing ratiometric signal amplification aptasensor for other biomarkers detection.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 42 条
[1]   The dichotomy in the preinvasive neoplasia to invasive carcinoma sequence in the pancreas: Differential expression of MUC1 and MUC2 supports the existence of two separate pathways of carcinogenesis [J].
Adsay, NV ;
Merati, K ;
Andea, A ;
Sarkar, F ;
Hruban, RH ;
Wilentz, RE ;
Goggins, M ;
Iocobuzio-Donahue, C ;
Longnecker, DS ;
Klimstra, DS .
MODERN PATHOLOGY, 2002, 15 (10) :1087-1095
[2]   Cell-mediated immune responses to MUC1 fusion protein coupled to mannan [J].
Apostolopoulos, V ;
Pietersz, GA ;
McKenzie, IFC .
VACCINE, 1996, 14 (09) :930-938
[3]  
Baldus SE, 1998, INT J CANCER, V79, P133, DOI 10.1002/(SICI)1097-0215(19980417)79:2<133::AID-IJC6>3.0.CO
[4]  
2-U
[5]   Probe-label-free electrochemical aptasensor based on methylene blue-anchored graphene oxide amplification [J].
Chen, Jing Rong ;
Jiao, Xiao Xia ;
Luo, Hong Qun ;
Li, Nian Bing .
JOURNAL OF MATERIALS CHEMISTRY B, 2013, 1 (06) :861-864
[6]  
Chen ZP, 2011, NAT MATER, V10, P424, DOI [10.1038/NMAT3001, 10.1038/nmat3001]
[7]   High-Performance Ratiometric Electrochemical Method Based on the Combination of Signal Probe and Inner Reference Probe in One Hairpin-Structured DNA [J].
Deng, Chunyan ;
Pi, Xiaomei ;
Qian, Pin ;
Chen, Xiaoqing ;
Wu, Wuming ;
Xiang, Juan .
ANALYTICAL CHEMISTRY, 2017, 89 (01) :966-973
[8]   Fluorescent detection of Mucin 1 protein based on aptamer functionalized biocompatible carbon dots and graphene oxide [J].
Ding, Yanjun ;
Ling, Jiang ;
Wang, Hao ;
Zou, Jiang ;
Wang, Kangkai ;
Xiao, Xianzhong ;
Yang, Minghui .
ANALYTICAL METHODS, 2015, 7 (18) :7792-7798
[9]   Noble Metal Nanoparticles for Biosensing Applications [J].
Doria, Goncalo ;
Conde, Joao ;
Veigas, Bruno ;
Giestas, Leticia ;
Almeida, Carina ;
Assuncao, Maria ;
Rosa, Joao ;
Baptista, Pedro V. .
SENSORS, 2012, 12 (02) :1657-1687
[10]   A SERS active bimetallic core-satellite nanostructure for the ultrasensitive detection of Mucin-1 [J].
Feng, Jingjing ;
Wu, Xiaoling ;
Ma, Wei ;
Kuang, Hua ;
Xu, Liguang ;
Xu, Chuanlai .
CHEMICAL COMMUNICATIONS, 2015, 51 (79) :14761-14763