Performance and short-term outcomes of three different transcatheter aortic valve replacement devices in patients with aortic stenosis: A single-center experience

被引:1
作者
Tzeng, Yun-Hsuan [1 ,2 ]
Lee, Yung-Tsai [3 ,4 ]
Tsao, Tien-Ping [2 ,3 ]
Lee, Kuo-Chen [2 ,3 ]
Huang, Kuan-Chih [3 ,5 ]
Hsiung, Ming-Chon [3 ]
Wei, Jeng [2 ,3 ]
Yin, Wei-Hsian [3 ,6 ]
机构
[1] Cheng Hsin Gen Hosp, Hlth Management Ctr, Div Med Imaging, Taipei, Taiwan
[2] Natl Def Med Ctr, Fac Med, Taipei, Taiwan
[3] Cheng Hsin Gen Hosp, Heart Ctr, 45 Zhenxing St, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Sch Med, Inst Microbiol & Immunol, Taipei, Taiwan
[5] Natl Taiwan Univ, Coll Med, Grad Inst Clin Med, Taipei, Taiwan
[6] Natl Yang Ming Univ, Sch Med, Fac Med, Taipei, Taiwan
关键词
Balloon-expandable valve; Mechanically expanded valve; Outcomes; Self-expanding valve; Transcatheter aortic valve replacement; SELF-EXPANDABLE VALVES; CORONARY OBSTRUCTION; IMPLANTATION; RISK; ECHOCARDIOGRAPHY;
D O I
10.1097/JCMA.0000000000000187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Data on whether different transcatheter aortic valve replacement (TAVR) devices and delivery approaches can achieve equally favorable outcomes when performed by a single heart team are scarce. We sought to compare the performance and short-term outcomes of three different TAVR devices-self-expanding Medtronic CoreValve (MCV), mechanically expanded Lotus valve, and balloon-expandable Edwards SAPIEN XT (SXT)-for the treatment of severe aortic stenosis (AS) in a single large-volume center in Taiwan. Methods: We retrospectively reviewed consecutive patients who underwent TAVR for the treatment of severe AS. Clinical outcomes were reported following Valve Academic Research Consortium 2 (VARC-2) criteria. The composite primary endpoint was combined all-cause mortality, myocardial infarction (MI), or disabling stroke within 180 days. Results: A total of 231 patients (MCV n=112, Lotus n=18, and SXT n=101) were included. The device and procedural success rates were similar among all three TAVR devices. At 30 days, there was no significant difference in all-cause mortality, cardiovascular mortality, periprocedural MI, stroke, major vascular complications, life-threatening bleeding, acute kidney injury (AKI, stage 2/3), or VARC-2 composite early safety endpoints. There was no difference among groups in the rate of primary endpoint within 180 days. Lack of procedural success, presence of acute coronary occlusion during TAVR, and presence of AKI (stage 3) after TAVR were independent predictors of adverse outcomes. Conclusion: TAVR using MCV, Lotus, or SXT was associated with similar 30- and 180-day clinical outcomes. The presence of periprocedural complications was one of the main determinants of short-term adverse outcomes.
引用
收藏
页码:827 / 834
页数:8
相关论文
共 22 条
[1]   1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves Results From the CHOICE Randomized Clinical Trial [J].
Abdel-Wahab, Mohamed ;
Neumann, Franz-Josef ;
Mehilli, Julinda ;
Frerker, Christian ;
Richardt, Doreen ;
Landt, Martin ;
Jose, John ;
Toelg, Ralph ;
Kuck, Karl-Heinz ;
Massberg, Steffen ;
Robinson, Derek R. ;
El-Mawardy, Mohamed ;
Richardt, Gert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (07) :791-800
[2]   Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement The CHOICE Randomized Clinical Trial [J].
Abdel-Wahab, Mohamed ;
Mehilli, Julinda ;
Frerker, Christian ;
Neumann, Franz-Josef ;
Kurz, Thomas ;
Toelg, Ralph ;
Zachow, Dirk ;
Guerra, Elena ;
Massberg, Steffen ;
Schaefer, Ulrich ;
El-Mawardy, Mohamed ;
Richardt, Gert .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (15) :1503-1514
[3]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[4]   Transcatheter aortic valve replacement-state of the art and a glimpse to the future: 'the Tailored Approach' [J].
Bedogni, Francesco ;
Frigiola, Alessandro ;
Ranucci, Marco ;
Brambilla, Nedy ;
Montone, Rocco Antonio ;
Agnifili, Mauro ;
Menicanti, Lorenzo ;
Testa, Luca .
EUROPEAN HEART JOURNAL SUPPLEMENTS, 2016, 18 (0E) :E86-E95
[5]   The safety of introducing a new generation TAVR device: one departments experience from introducing a second generation repositionable TAVR [J].
Bjursten, Henrik ;
Nozohoor, Shahab ;
Johansson, Malin ;
Zindovic, Igor ;
Appel, Carl-Fredrik ;
Sjogren, Johan ;
Dencker, Magnus ;
Olivecrona, Goran ;
Harnek, Jan ;
Koul, Sasha ;
Feldman, Ted ;
Reardon, Michael J. ;
Gotberg, Matthias .
BMC CARDIOVASCULAR DISORDERS, 2017, 17
[6]   Latest-Generation Transcatheter Aortic Valve Replacement Devices and Procedures [J].
Chamandi, Chekrallah ;
Puri, Rishi ;
Rodriguez-Gabella, Tania ;
Rodes-Cabau, Josep .
CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (09) :1082-1090
[7]   Zero Contrast Transfemoral Transcatheter Aortic Valve Replacement Using Fluoroscopy-Echocardiography Fusion Imaging [J].
Eskandari, Mehdi ;
Aldalati, Omar ;
Byrne, Jonathan ;
Dworakowski, Rafal ;
Wendler, Olaf ;
Alcock, Ema ;
Monaghan, Mark ;
MacCarthy, Philip .
AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (11) :1861-1862
[8]   Effect of Mechanically Expanded vs Self-Expanding Transcatheter Aortic Valve Replacement on Mortality and Major Adverse Clinical Events in High-Risk Patients With Aortic Stenosis The REPRISE III Randomized Clinical Trial [J].
Feldman, Ted E. ;
Reardon, Michael J. ;
Rajagopal, Vivek ;
Makkar, Raj R. ;
Bajwa, Tanvir K. ;
Kleiman, Neal S. ;
Linke, Axel ;
Kereiakes, Dean J. ;
Waksman, Ron ;
Thourani, Vinod H. ;
Stoler, Robert C. ;
Mishkel, Gregory J. ;
Rizik, David G. ;
Iyer, Vijay S. ;
Gleason, Thomas G. ;
Tchetche, Didier ;
Rovin, Joshua D. ;
Buchbinder, Maurice ;
Meredith, Ian T. ;
Gotberg, Matthias ;
Bjursten, Henrik ;
Meduri, Christopher ;
Salinger, Michael H. ;
Allocco, Dominic J. ;
Dawkins, Keith D. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2018, 319 (01) :27-37
[9]  
Jabbour Richard J, 2018, Interv Cardiol, V13, P137, DOI 10.15420/icr.2018.24.2
[10]   Delayed Coronary Obstruction After Transcatheter Aortic Valve Replacement [J].
Jabbour, Richard J. ;
Tanaka, Akihito ;
Finkelstein, Ariel ;
Mack, Michael ;
Tamburino, Corrado ;
Van Mieghem, Nicolas ;
de Backer, Ole ;
Testa, Luca ;
Gatto, Pamela ;
Purita, Paola ;
Rahhab, Zouhair ;
Veulemans, Verena ;
Stundl, Anja ;
Barbanti, Marco ;
Nerla, Roberto ;
Sinning, Jan Malte ;
Dvir, Danny ;
Tarantini, Giuseppe ;
Szerlip, Molly ;
Scholtz, Werner ;
Scholtz, Smita ;
Tchetche, Didier ;
Castriota, Fausto ;
Butter, Christian ;
Sondergaard, Lars ;
Abdel-Wahab, Mohamed ;
Sievert, Horst ;
Alfieri, Ottavio ;
Webb, John ;
Rodes-Cabau, Josep ;
Colombo, Antonio ;
Latib, Azeem .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (14) :1513-1524