Determination of azatadine in human plasma by liquid chromatography/tandem mass spectrometry

被引:3
|
作者
Zhu, Yan-rong [1 ]
Jia, Yan-yan [1 ]
Jiang, Ling [1 ]
Wang, Chao [1 ]
Ding, Li-kun [1 ]
Yang, Jing [1 ]
Li, Liang [1 ]
Zhao, Pei-xi [1 ]
Liu, Wen-xin [1 ]
Yi-Ding [1 ]
Wang, Li [1 ]
Wen, Ai-dong [1 ]
机构
[1] Fourth Mil Med Univ, Dept Pharm, Xijing Hosp, Xian 710032, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 23期
关键词
Azatadine; LC-MS/MS; Human plasma; Pharmacokinetics;
D O I
10.1016/j.jchromb.2011.05.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 degrees C and the residue was reconstituted with the mobile phase. 5 mu L of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm x 150 mm, I.D. 5 mu m, Agilent TC-C-18 column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1 M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 -> 248.2 m/z for azatadine, 383.3 -> 337.3 m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values. (C) 2011 Elsevier BM. All rights reserved.
引用
收藏
页码:2189 / 2193
页数:5
相关论文
共 50 条
  • [31] Determination of dextromethorphan and dextrorphan in human plasma by liquid chromatography tandem mass spectrometry
    Eichhold, TH
    Greenfield, LJ
    Hoke, SH
    Wehmeyer, KR
    JOURNAL OF MASS SPECTROMETRY, 1997, 32 (11): : 1205 - 1211
  • [32] A liquid chromatography/tandem mass spectrometry method for determination of obatoclax in human plasma
    Moorthy, Ganesh S.
    Norris, Robin E.
    Adamson, Peter C.
    Fox, Elizabeth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 971 : 30 - 34
  • [33] Determination of silodosin in human plasma by liquid chromatography-tandem mass spectrometry
    Zhao, Xia
    Liu, Yuwang
    Xu, Junyu
    Zhang, Dan
    Zhou, Ying
    Gu, Jingkai
    Cui, Yimin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3724 - 3728
  • [34] Determination of tandospirone in human plasma by a liquid chromatography–tandem mass spectrometry method
    Fengdan Jin
    Analytical and Bioanalytical Chemistry, 2011, 400 : 2881 - 2887
  • [35] Determination of telmisartan in human plasma by liquid chromatography-tandem mass spectrometry
    Li, PF
    Wang, YW
    Wang, Y
    Tang, YB
    Fawcett, JP
    Cui, YM
    Gu, JK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2): : 126 - 129
  • [36] Determination of allopurinol and oxypurinol in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Liu, Xia
    Ni, Xiao-Jia
    Shang, De-Wei
    Zhang, Ming
    Hu, Jin-Qing
    Qiu, Chang
    Luo, Fu-Tian
    Wen, Yu-Guan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 941 : 10 - 16
  • [37] Simultaneous determination of buprenorphine, norbuprenorphine and naloxone in human plasma by liquid chromatography/tandem mass spectrometry
    Liu, Yongzhen
    Li, Xiaohua
    Xu, Allan
    Nasser, Azmi F.
    Heidbreder, Christian
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 120 : 142 - 152
  • [38] Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry
    Saraner, Nihal
    Ozkan, Guler Yagmur
    Guney, Berrak
    Alkan, Erkin
    Burul-Bozkurt, Nihan
    Saglam, Onursal
    Fikirdesici, Ezgi
    Yaldirim, Mevlut
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 1 - 5
  • [39] Determination and Quantification of Phenytoin in Human Plasma by Liquid Chromatography with Electrospray Ionization Tandem Mass Spectrometry
    Roy, S. M. N.
    Yetal, S. M.
    Vaidya, V. V.
    Joshi, S. S.
    E-JOURNAL OF CHEMISTRY, 2008, 5 (01) : 169 - 176
  • [40] Reliable and sensitive determination of dutasteride in human plasma by liquid chromatography-tandem mass spectrometry
    Contractor, Pritesh
    Kurani, Hemal
    Guttikar, Swati
    Shrivastav, Pranav S.
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (09) : 1168 - 1176