Determination of azatadine in human plasma by liquid chromatography/tandem mass spectrometry

被引:3
|
作者
Zhu, Yan-rong [1 ]
Jia, Yan-yan [1 ]
Jiang, Ling [1 ]
Wang, Chao [1 ]
Ding, Li-kun [1 ]
Yang, Jing [1 ]
Li, Liang [1 ]
Zhao, Pei-xi [1 ]
Liu, Wen-xin [1 ]
Yi-Ding [1 ]
Wang, Li [1 ]
Wen, Ai-dong [1 ]
机构
[1] Fourth Mil Med Univ, Dept Pharm, Xijing Hosp, Xian 710032, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 23期
关键词
Azatadine; LC-MS/MS; Human plasma; Pharmacokinetics;
D O I
10.1016/j.jchromb.2011.05.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 degrees C and the residue was reconstituted with the mobile phase. 5 mu L of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm x 150 mm, I.D. 5 mu m, Agilent TC-C-18 column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1 M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 -> 248.2 m/z for azatadine, 383.3 -> 337.3 m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values. (C) 2011 Elsevier BM. All rights reserved.
引用
收藏
页码:2189 / 2193
页数:5
相关论文
共 50 条
  • [1] Determination of nicousamide in human plasma by liquid chromatography-tandem mass spectrometry
    Qi, Wenyuan
    Zhao, Qian
    Liu, Hongzhong
    Jiang, Ji
    Chen, Xiaoguang
    Hu, Pei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 77 : 158 - 162
  • [2] Determination of voriconazole in human plasma by liquid chromatography-tandem mass spectrometry
    Teng, G-Sh.
    Zhao, L. -Z.
    Li, X.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 (01): : 147 - 152
  • [3] Determination of Tropisetron in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry
    Sun, Junjie
    Xu, Yu
    Jiang, Bo
    Luo, Yanan
    Li, Na
    Guo, Qingxiang
    ANALYTICAL LETTERS, 2010, 43 (17) : 2672 - 2680
  • [4] Determination of tolperisone in human plasma by liquid chromatography/tandem mass spectrometry for clinical application
    Choi, Chang-Ik
    Park, Jung-In
    Lee, Hye-In
    Lee, Yun-Jeong
    Jang, Choon-Gon
    Bae, Jung-Woo
    Lee, Seok-Yong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 911 : 59 - 63
  • [5] Determination of picamilon concentration in human plasma by liquid chromatography-tandem mass spectrometry
    Cui, Wenqi
    Chen, Xiaoyan
    Zhan, Yan
    Zhang, Zhenzhong
    Zhang, Yifan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1181 - 1184
  • [6] Determination of tropisetron in human plasma by liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Zhong, Dafang
    Chen, Xiaoyan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) : 848 - 852
  • [7] Determination of Topiramate in Human Plasma using Liquid Chromatography Tandem Mass Spectrometry
    Popov, Tanja Vnucec
    Maricic, Lea Cvitkovic
    Prosen, Helena
    Voncina, Darinka Brodnjak
    ACTA CHIMICA SLOVENICA, 2013, 60 (01) : 144 - 150
  • [8] Determination of solifenacin in human plasma by liquid chromatography-tandem mass spectrometry
    Macek, Jan
    Ptacek, Pavel
    Klima, Josef
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3327 - 3330
  • [9] Determination of celecoxib in human plasma by liquid chromatography-tandem mass spectrometry
    Ptacek, Pavel
    Klima, Josef
    Macek, Jan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 899 : 163 - 166
  • [10] Determination of olprinone in human plasma utilizing liquid chromatography tandem mass spectrometry
    Zhu, Ping
    Wen, Yu-Guan
    Chen, Ji-Mei
    Zhuang, Jian
    Zhou, Zhi-Ling
    Zheng, Shao-Yi
    Wu, Ruo-Bin
    Xiao, Xue-Jun
    Lu, Cong
    Fan, Rui-Xin
    Guo, Hui-Ming
    Fan, Xiao-Ping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 198 - 202