Experimental study of complex two-phase instabilities during the start-up of a vertical thermosyphon reboiler operating under vacuum

被引:8
作者
Alane, Abdelmadjid [2 ]
Heggs, Peter J. [1 ]
机构
[1] Univ Leeds, Sch Proc Environm & Mat Engn, Ctr Computat Fluid Dynam, Fac Engn, Leeds LS2 9JT, W Yorkshire, England
[2] BP Plc, ICBT Sunbury, Sunbury On Thames TW16 7LN, Middx, England
关键词
Vertical thermosyphon; Reboiler; Low pressure; Instabilities; Start-up; FACILITY;
D O I
10.1016/j.cherd.2011.01.019
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper reports experimental studies of the start-up at reduced pressures (0.105-0.171 bar) and low heat fluxes (1.23-1.55 kW m(-2)) of the thermosyphon reboiler research facility in the Morton Laboratory at the University of Manchester. This is a full scale replica of an industrial sized natural circulation thermosyphon reboiler comprising 50 vertically mounted 25 mm OD tubes of 3 m length with water as the process fluid in the tubes and with steam condensing in the shell side of the reboiler. Unstable behaviour is obtained at start-up with flow-induced instabilities (geysering) when the level of the liquid within the tubes of the bundle is up to the top tubesheet (100% submergence) and also at 83% submergence of the tubes irrespective of the process pressure. At 100% submergence of the tubes, intermittent reversed flows in the entire loop with substantial vibrations are obtained. Chaotic behaviour is obtained at the lower submergence level of 83%. However, start-up at process pressures of 0.22 and 1.04 bar, and low heat fluxes with the entire thermosyphon loop flooded with liquid completely alleviated the flow-induced instabilities observed at the lower submergence levels within the tubes. The flow in the closed loop of liquid is induced very soon after the steam is introduced into the reboiler due to the buoyancy forces emanating from differences in density around the loop. The start-up is smooth and relatively quick, but further instrumentation and control are required for the introduction of the feed to the thermosyphon system once vapour is generated. A control strategy and procedure is proposed which will avoid the instabilities that inherently occur with start-up procedures currently practised in industry. (C) 2011 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:2012 / 2023
页数:12
相关论文
共 14 条
  • [1] The re-commissioned thermosyphon reboiler research facility in the Morton Laboratory
    Alane, A.
    Heggs, P. J.
    [J]. ADVANCED COMPUTATIONAL METHODS IN HEAT TRANSFER IX, 2006, 53 : 337 - +
  • [2] Alane A., 2007, THESIS U MANCHESTER
  • [3] ALANE A, 2007, HEFAT 2007 P 5 INT C
  • [4] ARNETH S, 2001, CHARACTERISTICS THER
  • [5] HEAT TRANSFER COEFFICIENTS AND CIRCULATION RATES FOR THERMOSIPHON REBOILERS
    BEAVER, PR
    HUGHMARK, GA
    [J]. AICHE JOURNAL, 1968, 14 (05) : 746 - +
  • [6] Operation of a vertical thermosiphon reboiler experimental facility at reduced pressures
    Benson, HRS
    Schnabel, T
    Webb, DR
    Heggs, PJ
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2004, 82 (A4) : 445 - 456
  • [7] BENSON HRS, 2003, THESIS UMIST MANCHES
  • [8] BOURE JA, 1973, NUCL ENG DES, V25, P165, DOI 10.1016/0029-5493(73)90043-5
  • [9] CHEXAL VK, 1972, AICHE J, V69, P37
  • [10] HARRISON ME, 1989, CHEM ENG-NEW YORK, V96, P130