Molecular Size-Selective Electrodialytic Desalters for Electrospray Ionization-Mass Spectrometry

被引:2
作者
Shelor, Charles Phillip [2 ]
Donegan, Michael [1 ]
机构
[1] Waters Corp, Milford, MA 01757 USA
[2] Univ Texas Arlington, Dept Chem & Biochem, Arlington, TX 76019 USA
关键词
NANOELECTROSPRAY IONIZATION; MATRIX-ISOLATION; PROTEINS; ONLINE; SUPPRESSOR; PRECONCENTRATION; REMOVAL; IMPACT; ACIDS;
D O I
10.1021/acs.analchem.2c02380
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A membrane-based electrodialytic desalter has been developed for the selective removal of buffer/salt constituents from a fluid stream while retaining larger charged molecules such as proteins prior to mass spectrometric (MS) detection. The salts are deleterious to MS causing signal suppression, formation of adducts, and eventual contamination of the inlet. The new device uses dialysis membranes (DMs) paired with ion exchange membranes (IEMs) flanking the carrier flow channel in a planar configuration. The DMs contact the carrier channel preventing adsorptive losses of large, charged molecules to the IEMs. Ions are removed under an applied electric field using four pairs of electrodes along the flow channel. Removal of both anions and cations is more energy intensive than conversion of a suitable MS friendly salt into its respective acid or base, for example, ammonium acetate into acetic acid. The energetics and optimal voltage profiles for both scenarios have been thoroughly investigated. The DMs resulted in nonlinear increases in energy required for desalting over standard IEM devices due to electroosmotic flow of water into the interstitial space between the membranes. For a device channel with nominal volume of 15.2 mu L, a maximum concentration of 200 mM ammonium acetate flowing at 0.25 mL/min was converted into acetic acid. Recovery of bovine serum albumin measured at 280 nm was 67%-96% at tested salt concentrations, and dispersion volumes were less than 200 mu L-2 and may be suitable for coupling to liquid chromatography.
引用
收藏
页码:11873 / 11880
页数:8
相关论文
共 41 条
[1]   Electroseparation of chitosan oligomers by electrodialysis with ultrafiltration membrane (EDUF) and impact on electrodialytic parameters [J].
Aider, Mohammed ;
Brunet, Serge ;
Bazinet, Laurent .
JOURNAL OF MEMBRANE SCIENCE, 2008, 309 (1-2) :222-232
[2]   Electrodeionization: Principles, Strategies and Applications [J].
Alvarado, Lucia ;
Chen, Aicheng .
ELECTROCHIMICA ACTA, 2014, 132 :583-597
[3]   Coupling of porous filtration and ion-exchange membranes in an electrodialysis stack and impact on cation selectivity: A novel approach for sea water demineralization and the production of physiological water [J].
Bazinet, Laurent ;
Moalic, Marianne .
DESALINATION, 2011, 277 (1-3) :356-363
[4]   ELECTRICAL FIELD-FLOW FRACTIONATION OF PROTEINS [J].
CALDWELL, KD ;
GIDDINGS, JC ;
MYERS, MN ;
KESNER, LF .
SCIENCE, 1972, 176 (4032) :296-&
[5]   Online Hydrophobic Interaction Chromatography-Mass Spectrometry for the Analysis of Intact Monoclonal Antibodies [J].
Chen, Bifan ;
Lin, Ziqing ;
Alpert, Andrew J. ;
Fu, Cexiong ;
Zhang, Qunying ;
Pritts, Wayne A. ;
Ge, Ying .
ANALYTICAL CHEMISTRY, 2018, 90 (12) :7135-7138
[6]   On-Line Electrodialytic Salt Removal in Electrospray Ionization Mass Spectrometry of Proteins [J].
Chen, Yongjing ;
Mori, Masanobu ;
Pastusek, Amanda C. ;
Schug, Kevin A. ;
Dasgupta, Purnendu K. .
ANALYTICAL CHEMISTRY, 2011, 83 (03) :1015-1021
[7]   Use of a novel cation-exchange restricted-access material for automated sample clean-up prior to the determination of basic drugs in plasma by liquid chromatography [J].
Chiap, P ;
Rbeida, O ;
Christiaens, B ;
Hubert, P ;
Lubda, D ;
Boos, KS ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :145-155
[8]   Desalting large protein complexes during native electrospray mass spectrometry by addition of amino acids to the working solution [J].
Clarke, David J. ;
Campopiano, Dominic J. .
ANALYST, 2015, 140 (08) :2679-2686
[9]   ANNULAR HELICAL SUPPRESSOR FOR ION CHROMATOGRAPHY [J].
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1984, 56 (01) :103-105
[10]   DUAL MEMBRANE ANNULAR HELICAL SUPPRESSORS IN ION CHROMATOGRAPHY [J].
DASGUPTA, PK ;
BLIGH, RQ ;
MERCURIO, MA .
ANALYTICAL CHEMISTRY, 1985, 57 (02) :484-489