Impact of small thrombus formation in restenotic bare-metal stent lesions associated with acute coronary syndrome: Identification by optical coherence tomography

被引:10
|
作者
Yamamoto, Masanori [1 ]
Takano, Masamichi [1 ]
Murakami, Daisuke [1 ]
Inami, Toru [1 ]
Kobayashi, Nobuaki [1 ]
Shirakabe, Akihiro [1 ]
Inami, Shigenobu [2 ]
Okamatsu, Kentaro [1 ]
Ohba, Takayoshi [1 ]
Aoki, Satoshi [1 ]
Seino, Yoshihiko [1 ]
Mizuno, Kyoichi [2 ]
机构
[1] Chiba Hokusoh Hosp, Nippon Med Sch, Ctr Cardiovasc, Chiba 2701694, Japan
[2] Nippon Med Sch, Div Cardiol, Tokyo 113, Japan
关键词
Acute coronary syndrome; Optical coherence tomography; Restenosis; Stents; Thrombus; SIROLIMUS-ELUTING STENT; BALLOON ANGIOPLASTY; FOLLOW-UP; MYOCARDIAL-INFARCTION; ARTERY DISEASE; IMPLANTATION; PATTERNS; HUMANS; TISSUE; PLAQUE;
D O I
10.1016/j.ijcard.2009.12.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although in-stent restenosis (ISR) after bare-metal stent (BMS) implantation is considered to be clinically benign, ISR is often associated with adverse complications, such as acute coronary syndrome (ACS). The frequency, type, and location of thrombi in ISR lesions and their clinical presentation have not yet been precisely validated. Methods: Thirty angiographic ISR lesions occurring within 3 to 8 months after stenting were evaluated by optical coherence tomography (OCT). A thrombus was defined as a mass protruding into the lumen with an irregular surface, and its type was divided into red or white. The maximum size of a thrombus and the longitudinal distance from the thrombus to the narrowest lumen were measured. Results: A thrombus was identified in 2 patients by angiography and in 10 patients by OCT (7% vs. 33%; P=0.01). OCT showed that 9 patients had white thrombus and another patient had both types of thrombi. ACS relevant to ISR was seen in 6 patients, and the frequency of ACS was significantly higher in patients with thrombus than in those without thrombus [50% (5/10) vs. 5% (1/20); P=0.003]. The maximum size of the thrombus was 412 +/- 220 mu m in height, 424 +/- 251 mu m in width, and the longitudinal distance between the thrombus and the minimum lumen area was 0.3 +/- 0.7 mm. Conclusions: One third of ISR lesions following BMS deployment dominantly contained a white thrombus, and half of them were associated with ACS. A small thrombus formation adjacent to the narrowest lumen in an ISR lesion may therefore contribute to the clinical presentation of ACS. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:169 / 173
页数:5
相关论文
共 50 条
  • [1] Difference of Tissue Characteristics Between Early and Very Late Restenosis Lesions After Bare-Metal Stent Implantation An Optical Coherence Tomography Study
    Habara, Maoto
    Terashima, Mitsuyasu
    Nasu, Kenya
    Kaneda, Hideaki
    Inoue, Katsumi
    Ito, Tsuyoshi
    Kamikawa, Shigeru
    Kurita, Tairo
    Tanaka, Nobuyoshi
    Kimura, Masashi
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Matsuo, Hitoshi
    Ueno, Katsumi
    Katoh, Osamu
    Suzuki, Takahiko
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) : 232 - 238
  • [2] Assessment by Optical Coherence Tomography of Stent Struts Across Side Branch - Comparison of Bare-Metal Stents and Drug-Eluting Stents
    Liu, Yong
    Imanishi, Toshio
    Kubo, Takashi
    Tanaka, Atsushi
    Kitabata, Hironori
    Tanimoto, Takashi
    Ino, Yasushi
    Ikejima, Hideyuki
    Tsujioka, Hiroto
    Komukai, Kenichi
    Ishibashi, Kohei
    Kashiwagi, Manabu
    Ozaki, Yuichi
    Hirata, Kumiko
    Mizukoshi, Masato
    Akasaka, Takashi
    CIRCULATION JOURNAL, 2011, 75 (01) : 106 - 112
  • [3] Acute coronary syndrome due to hinge movement of a bare-metal stent
    Yagi, Shusuke
    Kimura, Takehiko
    Hayashi, Ikurou
    Nishiuchi, Takeshi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 123 (03) : E64 - E66
  • [4] Optical coherence tomography guided in-stent thrombus removal in patients with acute coronary syndromes
    Di Giorgio, Alessandro
    Capodanno, Davide
    Ramazzotti, Vito
    Imola, Fabrizio
    Mallus, Maria Teresa
    Stazi, Filippo
    Paoletti, Giulia
    Biondi-Zoccai, Giuseppe
    Tamburino, Corrado
    Prati, Francesco
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) : 989 - 996
  • [5] The relationship between timing of prasugrel pretreatment and in-stent thrombus immediately after percutaneous coronary intervention for acute coronary syndrome: an optical coherence tomography study
    Katayama, Yosuke
    Kubo, Takashi
    Ino, Yasushi
    Kameyama, Takeyoshi
    Matsuo, Yoshiki
    Kitabata, Hironori
    Terada, Kosei
    Emori, Hiroki
    Aoki, Hiroshi
    Taruya, Akira
    Shimamura, Kunihiro
    Ota, Shingo
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    HEART AND VESSELS, 2018, 33 (10) : 1159 - 1167
  • [6] Qualitative and Quantitative Assessment of Stent Restenosis by Optical Coherence Tomography - Comparison Between Drug-Eluting and Bare-Metal Stents
    Nagoshi, Ryoji
    Shinke, Toshiro
    Otake, Hiromasa
    Shite, Junya
    Matsumoto, Daisuke
    Kawamori, Hiroyuki
    Nakagawa, Masayuki
    Kozuki, Amane
    Hariki, Hirotoshi
    Inoue, Takumi
    Ohsue, Tsuyoshi
    Taniguchi, Yu
    Iwasaki, Masamichi
    Nishio, Ryo
    Hiranuma, Noritoshi
    Konishi, Akihide
    Kinutani, Hiroto
    Miyoshi, Naoki
    Takaya, Tomofumi
    Yamada, Shinichiro
    Yasaka, Yoshinori
    Hayashi, Takatoshi
    Yokoyama, Mitsuhiro
    Kato, Hiroki
    Kadotani, Makoto
    Ohnishi, Yoshio
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2013, 77 (03) : 652 - 660
  • [7] Neoatherosclerosis as the Cause of Very Late Bare-metal Stent Restenosis: Optical Coherence Tomography Evaluation
    Ruiz-Garcia, Juan
    Jimenez-Valero, Santiago
    Galeote, Guillermo
    Sanchez-Recalde, Angel
    Garcia-Blas, Sergio
    Moreno, Raul
    REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (05): : 403 - 405
  • [8] Different Neoatherosclerosis Patterns in Drug-Eluting- and Bare-Metal Stent Restenosis - Optical Coherence Tomography Study -
    Nakamura, Daisuke
    Yasumura, Keisuke
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Yasumoto, Koji
    Tanaka, Akihiro
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Yamato, Masaki
    Egami, Yasuyuki
    Shutta, Ryu
    Sakata, Yasushi
    Tanouchi, Jun
    Nishino, Masami
    CIRCULATION JOURNAL, 2019, 83 (02) : 313 - 319
  • [9] Impact of coronary artery stent edge dissections on long-term clinical outcome in patients with acute coronary syndrome: An optical coherence tomography study
    Bouki, Konstantina P.
    Sakkali, Eleni
    Toutouzas, Konstantinos
    Vlad, Delia
    Barmperis, Dimitrios
    Phychari, Stavroula
    Riga, Maria
    Apostolou, Thomas
    Stefanadis, Christodoulos
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (02) : 237 - 246
  • [10] Optical coherence tomography guided in-stent thrombus removal in patients with acute coronary syndromes
    Alessandro Di Giorgio
    Davide Capodanno
    Vito Ramazzotti
    Fabrizio Imola
    Maria Teresa Mallus
    Filippo Stazi
    Giulia Paoletti
    Giuseppe Biondi-Zoccai
    Corrado Tamburino
    Francesco Prati
    The International Journal of Cardiovascular Imaging, 2013, 29 : 989 - 996