A Integrated Dedicated Outdoor Air System to Optimize Energy Saving

被引:4
作者
Chuah, Yew Khoy [1 ]
Yang, Jun Jie [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
关键词
outdoor air; IAQ; energy saving; enthalpy heat exchange; green building; DOAS;
D O I
10.3390/su12031051
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Outdoor air supply is required to maintain good indoor air quality (IAQ). For tropical or subtropical regions, warm and humid outdoor air would cause excess air-conditioning energy use. This study has proposed an integrated dedicated outdoor air system (IDOAS), which integrates the enthalpy exchange and outdoor air cooling into a unitary system. IDOAS could operate independently of central air-conditioning systems thus saving tremendous piping cost and energy needed to deliver chilled water to outdoor air unit in a conventional centralized system. An experimental unit of IDOAS was built to prove this novel concept. Enthalpy exchange efficiency was tested to be about 44%. The test results show that about 44% of energy needed to condition the outdoor air can be saved. A reverse Rankine refrigeration cycle was integrated to cool the outdoor air. Due to this integrated configuration, the air passing through the condenser would be at a lower temperature. The consequent lower refrigerant condensing temperature would improve the cooling cycle efficiency. The cooling coefficient of performance (COP) was improved by about 46%. In addition, the outdoor air could be conditioned to a lower humidity before being supplied to space, which would improve the thermal comfort. The test results of this novel IDOAS show that it could provide good air quality at lower energy use.
引用
收藏
页数:12
相关论文
共 21 条
[1]  
Chaeand Y.T., 2010, P 4 NAT C IBPSA US N, P458
[2]   AN EXPERIMENTAL STUDY ON THE PERFORMANCE OF RADIANT FLOOR COOLING MODULES [J].
Chien, K. C. ;
Chuah, Y. K. ;
Chang, W. T. .
INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2013, 21 (02)
[3]  
Chuah Y.K., 2017, P PERF ASS DED OUTD
[4]  
Dieckmann J, 2003, ASHRAE J, V45, P58
[5]  
Hong Kong Environmental Protection Department, 2003, IAQ CERT SCHEM
[6]  
Larrañaga MD, 2008, ASHRAE J, V50, P34
[7]  
LEVENHAGEN JI, 1992, ASHRAE J, V34, P40
[8]   Applying a novel extra-low temperature dedicated outdoor air system in office buildings for energy efficiency and thermal comfort [J].
Li, Han ;
Lee, W. L. ;
Jia, Jie .
ENERGY CONVERSION AND MANAGEMENT, 2016, 121 :162-173
[9]   Energy consumption analysis on a dedicated outdoor air system with rotary desiccant wheel [J].
Liu, Weiwei ;
Lian, Zhiwei ;
Radermacher, Reinhard ;
Yao, Ye .
ENERGY, 2007, 32 (09) :1749-1760
[10]   An energy benchmarking model for ventilation systems of air-conditioned offices in subtropical climates [J].
Mui, K. W. ;
Wong, L. T. ;
Law, L. Y. .
APPLIED ENERGY, 2007, 84 (01) :89-98