Purpose: To describe a fatal case of late aortic perforation by an endograft-anchoring stent. Methods and Results: A 69-year-old woman presented 2 years after thoracoabdominal aneurysm repair with a 9-cm dilatation of the descending thoracic aorta proximal to the conventional aortic graft. A 38-mm Dacron graft with multiple Gianturco Z-stents sutured inside was placed transluminally across the aortic arch such that part of the uncovered portion of the proximal stent was partially across the left subclavian orifice. Four months later, the patient died from massive hemorrhage. Autopsy showed that the uncovered portion of the proximal stent had perforated the aortic arch. Conclusions: This case stresses the need for low-profile stent-grafts and smaller, more flexible introducer systems. Anchoring stents must be flexible, less traumatic, and strong enough to create a watertight seal even in tortuous vessels. To avoid aortic arch damage by thoracic stent-grafts, the proximal stent should be fully covered by the fabric.
引用
收藏
页码:274 / 277
页数:4
相关论文
共 8 条
[1]   INFRARENAL AORTIC-ANEURYSM STRUCTURE - IMPLICATIONS FOR TRANSFEMORAL REPAIR [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
DEWEESE, JA .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (01) :44-50
[2]  
Hramiec JE, 1997, ANN THORAC SURG, V63, P209
[3]   DELAYED RUPTURE OF AORTIC-ANEURYSMS FOLLOWING ENDOVASCULAR STENT GRAFTING [J].
LUMSDEN, AB ;
ALLEN, RC ;
CHAIKOF, EL ;
RESNIKOFF, M ;
MORITZ, MW ;
GERHARD, H ;
CASTRONUOVO, JJ .
AMERICAN JOURNAL OF SURGERY, 1995, 170 (02) :174-178
[4]   Endovascular stent-graft repair of thoracic aortic aneurysms [J].
Mitchell, RS ;
Dake, MD ;
Semba, CP ;
Fogarty, TJ ;
Zarins, CK ;
Liddell, RP ;
Miller, DC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05) :1054-1060
[5]   ENDOVASCULAR REPAIR OF ABDOMINAL AORTIC-ANEURYSMS AND OTHER ARTERIAL LESIONS [J].
PARODI, JC .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (04) :549-557
[6]   Treatment of malignant esophageal obstructions with covered metallic Z stents: Long-term results in 52 patients [J].
Saxon, RR ;
Barton, RE ;
Katon, RM ;
Petersen, BD ;
Lakin, PC ;
Timmermans, H ;
Uchida, B ;
Keller, FS ;
Rosch, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 6 (05) :747-754
[7]  
White GH, 1997, J ENDOVASC SURG, V4, P124, DOI 10.1583/1074-6218(1997)004<0124:TYEWTW>2.0.CO
[8]  
2