Overview, consequences, and strategies for overcoming matrix effects in LC-MS analysis: a critical review

被引:108
作者
Nasiri, Azadeh [1 ,2 ]
Jahani, Reza [1 ]
Mokhtari, Shaya [3 ,4 ]
Yazdanpanah, Hassan [1 ,2 ]
Daraei, Bahram [1 ]
Faizi, Mehrdad [1 ]
Kobarfard, Farzad [3 ,4 ,5 ]
机构
[1] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmacol & Toxicol, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Food Safety Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Cent Res Labs, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Phytochem Res Ctr, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Med Chem, Tehran, Iran
关键词
CHROMATOGRAPHY-MASS-SPECTROMETRY; SAMPLE PREPARATION TECHNIQUES; LABELED INTERNAL STANDARDS; SOLID-PHASE EXTRACTION; ELECTROSPRAY-IONIZATION; ION SUPPRESSION; POSTCOLUMN INFUSION; QUANTITATIVE-ANALYSIS; CHEMICAL-IONIZATION; EFFECT COMPENSATION;
D O I
10.1039/d1an01047f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The high-performance liquid chromatography-mass spectrometry (LC-MS) technique is widely applied to routine analysis in many matrices. Despite the enormous application of LC/MS, this technique is subjected to drawbacks called matrix effects (MEs) that could lead to ion suppression or ion enhancement. This phenomenon can exert a deleterious impact on the ionization efficacy of an analyte and subsequently on the important method performance parameters. LC-MS susceptibility to MEs is the main challenge of this technique in the analysis of complex matrices such as biological and food samples. Nowadays, the assessment, estimation, and overcoming of the MEs before developing a method is mandatory in any analysis. Two main approaches including the post-column infusion and post-extraction spike are proposed to determine the degree of MEs. Different strategies can be adopted to reduce or eliminate MEs depending on the complexity of the matrix. This could be done by improving extraction and clean-up methods, changing the type of ionization employed, optimization of liquid chromatography conditions, and using corrective calibration methods. This review article will provide an overview of the MEs as the Achilles heel of the LC-MS technique, the causes of ME occurrence, their consequences, and systemic approaches towards overcoming MEs during LC-MS-based multi-analyte procedures.
引用
收藏
页码:6049 / 6063
页数:15
相关论文
共 127 条
[31]   A liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric method for the determination of organosulfur compounds in petroleum asphalt cements [J].
da Silveira, Gessica Domingos ;
Faccin, Henrique ;
Claussen, Luis ;
Goularte, Rayane Bueno ;
Do Nascimento, Paulo C. ;
Bohrer, Denise ;
Cravo, Margareth ;
Leite, Leni F. M. ;
de Carvalho, Leandro Machado .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1457 :29-40
[32]   Matrix effect management in liquid chromatography mass spectrometry: the internal standard normalized matrix effect [J].
De Nicolo, Amedeo ;
Cantu, Marco ;
D'Avolio, Antonio .
BIOANALYSIS, 2017, 9 (14) :1093-1105
[33]   Multidimensional Liquid Chromatography Coupled with Tandem Mass Spectrometry for Identification of Bioactive Fatty Acyl Derivatives [J].
Divito, Erin B. ;
Kroniser, Kristin M. ;
Cascio, Michael .
FRONTIERS IN PHYSIOLOGY, 2016, 7
[34]   Electrolyte-Induced Ionization Suppression and Microcystin Toxins: Ammonium Formate Suppresses Sodium Replacement Ions and Enhances Protiated and Ammoniated Ions for Improved Specificity in Quantitative LC-MS-MS [J].
Draper, William M. ;
Xu, Dadong ;
Perera, S. Kusum .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :4153-4160
[35]   Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers [J].
El-Aneed, Anas ;
Cohen, Aljandro ;
Banoub, Joseph .
APPLIED SPECTROSCOPY REVIEWS, 2009, 44 (03) :210-230
[36]   Development of a Sensitive and Rapid Method for Determination of Acrylamide in Bread by LC-MS/MS and Analysis of Real Samples in Iran IR [J].
Eslamizad, Samira ;
Kobarfard, Farzad ;
Tabib, Kimia ;
Yazdanpanah, Hassan ;
Salamzadeh, Jamshid .
IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2020, 19 (01) :413-423
[37]   Comparison of approaches to deal with matrix effects in LC-MS/MS based determinations of mycotoxins in food and feed [J].
Fabregat-Cabello, N. ;
Zomer, P. ;
Sancho, J. V. ;
Roig-Navarro, A. F. ;
Mol, H. G. J. .
WORLD MYCOTOXIN JOURNAL, 2016, 9 (02) :149-161
[38]   Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples [J].
Fang, Nianbai ;
Yu, Shanggong ;
Ronis, Martin J. J. ;
Badger, Thomas M. .
EXPERIMENTAL BIOLOGY AND MEDICINE, 2015, 240 (04) :488-497
[39]   Overcoming matrix effects using the dilution approach in multiresidue methods for fruits and vegetables [J].
Ferrer, Carmen ;
Lozano, Ana ;
Agueera, Ana ;
Giron, A. Jimenez ;
Fernandez-Alba, A. R. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (42) :7634-7639
[40]  
Flarakos J, 2021, FUTURE SCI, V13, P605