Fast spin-echo triple-echo Dixon (fTED) technique for efficient T2-weighted water and fat imaging

被引:41
作者
Ma, Jinafei
Son, Jong Bum
Zhou, Yuxiang
Le-Petross, Huong
Choi, Haesun
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[2] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
关键词
dixon imaging; fast spin echo; water and fat; fast triple-echo Dixon; parallel imaging;
D O I
10.1002/mrm.21268
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Previously published fast spin-echo (FSE) implementations of a Dixon method for water and fat separation all require multiple scans and thus a relatively long scan time. Further, the minimum echo spacing (esp), a time critical for FSE image quality and scan efficiency, often needs to be increased in order to bring about the required phase shift between the water and fat signals. This work proposes and implements a novel FSE triple-echo Dixon (fTED) technique that can address these limitations. In the new technique, three raw images are acquired in a single FSE scan by replacing each frequency-encoding gradient in a conventional FSE with three consecutive gradients of alternating polarity. The timing of the three gradients is adjusted by selecting an appropriate receiver bandwidth (RBW) so that the water and fat signals for the three corresponding echoes have a relative phase shift of -180 degrees, 0 degrees, and 180 degrees, respectively. A fully automated postprocessing algorithm is then used to generate separate water-only and fat-only images for each slice. The technique was implemented with and without parallel imaging. We demonstrate that the new fTED technique enables both uniform water/fat separation and fast scanning with uncompromised scan parameters, including applications such as T-2-weighted separate water and fat imaging of the abdomen during breath-holding. Magn Reson Med 58:103-109, 2007. (c) 2007 Wiley-Liss, Inc.
引用
收藏
页码:103 / 109
页数:7
相关论文
共 37 条
  • [31] Effective blood signal suppression using double inversion-recovery and slice reordering for multislice fast spin-echo MRI and its application in simultaneous proton density and T2 weighted imaging
    Kuribayashi, H
    Tessier, JJ
    Checkley, DR
    Wang, YX
    Hultin, L
    Waterton, JC
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) : 881 - 888
  • [32] Extrasellar extension of pituitary lesions - Comparison of T2-wieighted fast spin echo MRI with T1-weighted sequences
    Wolansky, LJ
    Rao, SB
    Schulder, M
    Elias, BJ
    Brautigan, R
    Choudhri, A
    Kalnin, A
    Frohman, LP
    Lee, HJ
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1996, 2 (02): : 147 - 152
  • [33] Processing of radial fast spin-echo data for obtaining T2 estimates from a single k-space data set
    Altbach, MI
    Bilgin, A
    Li, ZQ
    Clarkson, EW
    Trouard, TP
    Gmitro, AF
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 549 - 559
  • [34] Accelerated Cardiac T2 Mapping using Breath-hold Multiecho Fast Spin-Echo Pulse Sequence with k-t FOCUSS
    Feng, Li
    Otazo, Ricardo
    Jung, Hong
    Jensen, Jens H.
    Ye, Jong C.
    Sodickson, Daniel K.
    Kim, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1661 - 1669
  • [35] Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging
    Erdem, LO
    Erdem, CZ
    Acikgoz, B
    Gundogdu, S
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 55 (02) : 277 - 282
  • [36] MRI of the Knee Ligaments and Menisci: Comparison of Isotropic-Resolution 3D and Conventional 2D Fast Spin-Echo Sequences at 3 T
    Subhas, Naveen
    Kao, Amy
    Freire, Maxime
    Polster, Joshua M.
    Obuchowski, Nancy A.
    Winalski, Carl S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : 442 - 450
  • [37] Diffusion Weighted Imaging A Comprehensive Evaluation of a Fast Spin Echo DWI Sequence With BLADE (PROPELLER) k-Space Sampling at 3 T, Using a 32-Channel Head Coil in Acute Brain Ischemia
    Attenberger, Ulrike I.
    Runge, Val M.
    Stemmer, Alto
    Williams, Kenneth D.
    Naul, L. Gill
    Michaely, Henrik J.
    Schoenberg, Stefan O.
    Reiser, Maximilian F.
    Wintersperger, Bernd J.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (10) : 656 - 661